| Price Range: | 150,000~200,000 USD |
|---|---|
| Minimum Order Quantity: | 1 Set/Sets |
| Certification Requirements: | western manufacturer |
| Post Date: | Mar 21, 2008 |
| Expiry date: | Jul 20, 2008 |
|
|
European or Japan or USA |
X-ray tube Tube: Cu, Bf Focus: 2.0x12mm Max output: 3kw X-ray generator Max output: 3kw Tube voltage/tube current stability: + 0.01% (for 10% power fluctuations) Max tube voltage: 60kv Max tube current : 80mA Tube voltage step width: 1kv Tube current step width: 1mA Overload limit setting: Change setting to suit tube type: Tube protection: Overload, overvoltage, overcurrent, cooling water abnormalities Safety mechanics: Door interlock mechanics (X-ray generated after containing door closed) Goniometer Type: vertical Goniometer radius: 275mm standard (variable from 200 to 275mm) X-ray beam to attachment base distance: 220mm, 85mm Main step angle: 0.0001x ( ), 0.0002 x ( ) Angular reproducibility: 0.0002 Operation angle range: -12 to 164x(20), -6 to 82 (CS), -5 to 132 ( d) Operation system: linked; individual Operation mode: Continuous scan measurement, step scan measurement, calibration positioning Slewing speed: 1000o/minute ( ) Operation speed: 0.1 to 50o/minutes ( ), 0.1 to 100o( ) Divergence slit (DS): 0.5o, 1o, 2o, 0.05omm Scattering prevention slit (SS): 0.5o, 1o, 2o Receiving slit (RS): 0.15mm, 0.3mm Detector/counter Detector: Scintillation counter Scintillator: NaI Scaler: Preset time. 0.1 to 1000s; digits; 7 HV/PHA: 500 to 1200 V high-voltage power supply, and window auto controlled Data Processing Unit Computer type: IBM, COMPAC , PC/AT compatible OS: Original Windows XP CPU: 3.600 GHz RAM: 2 GB Processor duo centreno Display: Monitor CL 17 Hard Disk: 120 GB WD Printer: A4 color laser printer Controlled elements: Goniometer, X-ray generation, tube voltage, tube current, detector high voltage, PHA, scaler Basic data processing: Smoothing, BG elimination, K�1-K�2 separation, peak searching, peak width at half height, integrated intensity, systematic error correction, internal/external standard correction, operations between data, graphic display Qualitative analysis: Database generation, automatic searching (ICDD PDF2/PDF4 optional) Quantitative analysis: Calibration curve generation, quantitative analysis Equip. .Inst, training 4 person |
X-ray diffraction apparatus XRD
|
2 |
|
|
|
|
|
This member's information has NOT been authenticated or verified by Alibaba or any third party.
Only Alibaba Gold Suppliers and
TrustPass members have completed an Authentication and Verification procedure conducted by third-party credit-reporting agencies.
For more information on Alibaba Gold Supplier and TrustPass membership, Click here