X-Ray Equipment


Price Range: 150,000~200,000 USD
Minimum Order Quantity: 1 Set/Sets
Certification Requirements: western manufacturer
Post Date: Mar 21, 2008
Expiry date: Jul 20, 2008

Click to send a quotation

Detailed Buying Lead Description
 

European or Japan or USA

X-ray tube

Tube: Cu, Bf

Focus: 2.0x12mm

Max output: 3kw

 

X-ray generator

Max output: 3kw

Tube voltage/tube current stability:  + 0.01% (for 10% power fluctuations)

Max tube voltage:  60kv

Max tube current :  80mA

Tube voltage step width:  1kv

Tube current step width:  1mA

Overload limit setting:  Change setting to suit tube type:

Tube protection:  Overload, overvoltage, overcurrent, cooling water abnormalities

Safety mechanics:  Door interlock mechanics (X-ray generated after containing door closed)

 

Goniometer

Type: vertical

Goniometer radius: 275mm standard (variable from 200 to 275mm)

X-ray beam to attachment base distance:  220mm, 85mm

Main step angle:  0.0001x ( ), 0.0002 x ( )

Angular reproducibility:  0.0002

Operation angle range: -12 to 164x(20), -6 to 82 (CS), -5 to 132 ( d)

Operation system:   linked;  individual

Operation mode:  Continuous scan measurement, step scan measurement, calibration positioning

Slewing speed:  1000o/minute ( )

Operation speed: 0.1 to 50o/minutes ( ), 0.1 to 100o(  )

Divergence slit (DS):  0.5o, 1o, 2o, 0.05omm

Scattering prevention slit (SS):  0.5o, 1o, 2o

Receiving slit (RS):  0.15mm, 0.3mm

 

Detector/counter

Detector:  Scintillation counter

Scintillator:  NaI

Scaler:  Preset time. 0.1 to 1000s; digits; 7

HV/PHA:  500 to 1200 V high-voltage power supply, and window auto controlled

 

Data Processing Unit

Computer type:  IBM, COMPAC , PC/AT compatible

OS:  Original Windows XP

CPU:  3.600 GHz

RAM: 2 GB Processor duo centreno

Display:  Monitor CL 17

Hard Disk: 120 GB WD

Printer:  A4 color laser printer

Controlled elements:  Goniometer, X-ray generation, tube voltage, tube current, detector high voltage, PHA, scaler

Basic data processing:  Smoothing, BG elimination, K�1-K�2 separation, peak searching, peak width at half height, integrated intensity, systematic error correction, internal/external standard correction, operations between data, graphic display

Qualitative analysis: Database generation, automatic searching (ICDD PDF2/PDF4 optional)      

Quantitative analysis:  Calibration curve generation, quantitative analysis

Equip. .Inst, training 4 person

X-ray diffraction apparatus

XRD

 

2

 

 

 

 

Sign in to view this buyer's contact information.
Not an Alibaba member yet?

This member's information has NOT been authenticated or verified by Alibaba or any third party. Only Alibaba Gold Suppliers and TrustPass members have completed an Authentication and Verification procedure conducted by third-party credit-reporting agencies.
For more information on Alibaba Gold Supplier and TrustPass membership, Click here



Email this page Bookmark this page Print this Page