View this buyer's contact information please Sign in now!
Not a member yet? It takes less than a minute to Join FREE now!
|
Parameters |
Specifications |
|
Voltage |
575 V |
|
Frequency |
50 to 60 Hz |
|
Phase and wiring configuration |
3 Phase Delta |
|
Rated power |
26 to 27 kW |
|
RPM |
> 1800 during normal power generating |
|
Overspeed |
Overspeed capability to 3600 RPM on intermittent basis; up to 50 overspeed occurrences during the life of the generator |
|
Maximum power service factor |
>=1.15 at 40C >=1.00 at 50C |
|
Insulation |
F class or better (H class preferred) |
|
Weight |
<= 460 lb |
|
Frame |
IEC 180 frame or equivalent. D-type 350 mm diameter flange has four bolts holes equally spaced on a 300 mm diameter circle |
|
Housing |
TEFC (Totally Enclosed Fan Cooled) design or equivalent suitable for long-term outdoor exposure in high solar insulation, desert type sites |
|
Protection |
IP 55 or better (withstand water from hose at any angle) |
|
Front Bearing |
Cylindrical roller bearing for high radial loads |
|
Bearing Loads |
See Figure 1 |
|
Life |
18k hours L10 |
|
Seal |
Double Lip to prevent oil from leaking past shaft Shaft end of generator will be exposed to oil splash Maximum oil temperature of 90C |
|
Seal Life |
18k hours L10 |
|
Rotor Balance |
50% of the NEMA rating |
|
Start up Torque |
TBD |
|
Locked rotor current |
550% to 750 % of Full Load Current |
|
Power factor at the rated power |
> 0.8 |
|
Power factor at � of the rated power |
> 0.44 |
|
Efficiency at the rated power |
>=94% |
|
Efficiency at � of the rated power |
>= 91% |
|
Operating temperature at the rated power |
-30 to +50 癈. |
|
Exposed Surface Treatment |
Outer surfaces shall be protected by finishes commensurate with the environment and life of the unit. White paint or other high solar reflectivity color should be used for the exterior coating. Outer surfaces on the shaft end of the machine will be exposed to warm air at 60C. |
|
Moisture Protection |
Protection against condensation and high humidity shall consist of drain valves (or equivalent) in the lowest point of the units frame when rotated through 90 degrees |
|
Rain |
Withstand 50 mm per hour with a 65 km/h (40 mph) wind for a period of 15 minutes |
|
Snow/Ice/Hail |
Withstand 0.3 m of snow for 24 hours with a 250 Pa (4 psi) snow load or a 50 mm ice load. When the above snow or ice melts, run-off water shall have no detrimental effect on the unit. The unit should also be able to withstand hail with the diameter of 20 mm or greater. |
|
Wind |
Operation in winds up to 65 km/h (40 mph) |
|
Sand/Dust |
Withstand a dust concentration of 0.01 g/l (0.3 grams per cubic feet) blowing at a wind velocity of 32 km/h (20 mph) without degradation |
|
Altitude |
0 to 1800 m (6000 ft) unless otherwise specified by SES |
|
Attitude |
The units frame will rotate 90 degrees with respect to the earths surface as the dish tracks the sun |
Can you supply these Products? Display your Products now!