2 years warranty and 24V 800W AC to DC converter power supply for monitoring system smps

  • 1-499 Pieces
    $45.86
  • >=500 Pieces
    $41.93
Quantity:
- + Pieces available
0piecesselected, US $in total
View Details
Shipping fee:
Depends on the order quantity.
Lead Time:
10 day(s) after payment received
Customization:
Customized logo (Min. Order: 1000 Pieces)
Customized packaging (Min. Order: 1000 Pieces)

More

Graphic customization (Min. Order: 1000 Pieces) Less
Contact Supplier
Samples - $45.86 /Piece, 1 Piece (Min. Order): Buy Samples
Loading... Add To Cart
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
KAIHUI
Model Number:
K18C-UP800S24F
Output Power:
>500W
Output Type:
Single
Input Voltage:
100-240V AC
Output Voltage:
24VDC
Output Frequency:
50-60Hz
Output Current:
33.4A
Name:
24V 800W AC to DC converter power supply
Dimension:
168*82*60mm
Protection:
Overload,short circuit,low-voltage,over-voltage,over-temperature
Efficiency:
92%
Warranty:
2 Years
Safety Standards:
GB4943 EN60950
EMC Standards:
EN55015
ODM/OEM:
YES
Weight:
0.8kg
Power factor:
PF>0.98/115V & PF>0.95/230V

Packaging & Delivery

Selling Units:
Single item
Single package size: 
19X10X8 cm
Single gross weight:
1.0 kg
Package Type:
1pcs/box Standard packing.
Lead Time :
Quantity(Piece) 1 - 20 >20
Est. Time(days) 10 To be negotiated

2 years warranty and 24V 800W AC to DC converter power supply for monitoring system smps

Product Description

 Features: 

1,Small size,high efficiency

2,International universal full voltage input

3,Built-in active PFC function

4,Built-in filter,low noise,high reliability

5,Overload,short circuit,low-voltage,over-voltage,over-temperature etc. protection function

 

 parameter           Item No.

K18C-UP800S12FK18C-UP800S24FK18C-UP800S30FK18C-UP800S36FK18C-UP800S48F

 

 

Output

 

 

 

 

 

 

 

DC Output Voltage

+12V+24V

+30V

+36V

+48V

 

 Rated Current

20cfm fan

58.4A33.4A26.7A22.3A16.7A
natural cooling 33.4A20.8A 18.4A16.7A12.5A

Current Range

Rated power

20cfm fan

 700.8W 801.6W 801W802.8W801.6W

natural cooling

400W500W550W 600W600W

Ripple & Noise

 150mVp-p300mVp-p 350mVp-p400mVp-p400mVp-p

DC volltage ADJ

11.4-12.6V22.8-25.2V28.5-31.5V34.2-37.8V45.6-50.4V

Output v.Tolerance

±1%±1%±1%±1%±1%

Line Regulation

±0.5%

Load Regulation

±1%

Setup,Rise,Hold up time

300ms,20ms,12ms

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

Input Voltage range

100V~240V AC;

AC Current

3.8A/230Vac  7.6A@115Vac

Input frequency

50-60Hz

Efficiency

91.5%

92%93%93%94%

Power factor

PF>0.98/115V & PF>0.95/230V

Inrush currentCool start 60A/230Vac
Leakage Current<0.5mA@240V

Protection

Over load protection105~150% Hiccup protection,automatic recovery
Short circuit protectionLocked protection,  return to normal after restart
Output over-voltage protection>120% Shut down,Locked protection,  return to normal after restart
Over-temperature protectionTS1 position>105 it will be protection, then automatic recovery
FunctionFan assist power supply12V 0.3A power for fan ,tolerance±15%

Environment

 

 

Working Temp.,Humidity

-20~70,10~90% RH,No condensation

Storage Temp.,Humidity

-20~85,10~95% RH

Temperature drift

±0.03%/(0~50)

Vibration 

10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES

 

Safety & EMC standards

Safety standards

GB4943 EN60950
Withstand Voltage 

I/P-O/P:3KV; I/P-FG:1.8KV;O/P-FG:0.6KV AC 1min

Insulation resistance

I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms

EMC standards 

EN55015

 Other

  

MTBF

>50K hrs

Dimension

168*82*60MM ( L*W*H) 

Weight

0.8Kg

Note:   

1,All parameter 230VAC input,rated load,environment temperature 25℃,measured under conditions of 70% humidity;

2, Accuracy:including set up tolerance,line regulation,Load regulation ect.;

3,Ripple test:30cm long wire connect power supply and load, load end parallel 0.1u and 47u capacitor,the 4,20MHz oscilloscope was measured at the load end.

4,Line regulation:at rated load conditions, the input voltage change from low to high measured

5, Load regulation:the measured output   from 0-100% load changes measured.

     6,The load is more than 400W,  need to add at least 10CFM to heat dissipation.

    

 

Related Products

 

 

 

Packaging & Shipping

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Payment&Shipping

Payment
We accept T/T, L/C,or Western Union,if you have any
problems about payment,please contact us

Shipping
15-20 days after sample approval and deposit received.
Tracking No. will be sent to you after delivery and you
will get every important shipping status by email

FAQ

Q1. Can I have a sample order for power supply?
A1: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

 

Q2: Do you accept OEM/ODM for the switching power supply  ?

A2: Yes. we do.

 

Q3:How about the quality?

A3:We have the better professional and experienced engineers team and strict QA and QC system.Repair rate under 0.1%~0.2%

 

Q4:What is PFC?
A4:PFC stands for Power Factor Correction. The purpose of PFC is to improve the ratio of apparent power and real power. The power factor is only 0.5~0.7 in non-PFC models. In PFC models, the power factor can reach above 0.9. The calculation formulas are as below: 
Apparent Power=Input Voltage x Input Current (VA) 

Real Power= Input Voltage x Input Current x Power Factor (W)