Overview
Quick Details
Place of Origin:
Fujian, China (Mainland)
Brand Name:
all-sun
Model Number:
EM5511
Measuring Current Range:
400uA-10A
Measuring Voltage Range:
400mV-250V
Measuring Resistance Range:
400 Ω-40 MΩ
Measuring Capacitance Range:
4 nF- 100 uF
Measuring Inductance Range:
400mG- 4000mG
Operating Temperature:
0 ~ 40℃
Dimensions:
162x83x47mm
Safety rate:
CATII 250V
Display:
3 3/4 digit LCD
AC Voltage:
4/40/400/600V
DC Voltage:
0.4/4/40/400/600V
AC Current:
400u/4000u/40m/400m/10A
DC Current:
400u/4000u/40m/400m/10A

Packaging & Delivery

Selling Units:
Single item
Single package size: 
22X14X10 cm
Single gross weight:
0.9 kg
Package Type:
Portable case and carton box, please see picture for more detail.
Lead Time :
Quantity(Piece) 1 - 30 31 - 50 >50
Est. Time(day) 4 5 To be negotiated
Product Description

 FEATURE 

 1) High-performance

 2) Display: 3 3/4-backlight LCD display, max.reading of 3999                                3) Data-hold mode

 4) Auto polarity indication

 5) Manual range and autorange mode

 6) Auto/manual power-off

 7) Relative mode

 8) Overload protection: "OL" shown on the LCD

 9) Low battery indication

 

SPECIFICATION 

> Negative Polarity Indiaction: "-" displayed automatically

> Sampling Rate: 2-3 times/sec

> Operating Temperature: 0-40 degree C,<75%RH

> Storage Temperature: -30-60 degree C,<85%RH

> Operating Altitude: 0 to 2000 meters

> Battery: 9V,6F22 or equivalent

> Dimensions: 162x83x47mm

> Weight: about 310g (including battery and the holster)

 

Technical Specifications 

Accuracy is specified for a period of one year after calibration

and at 18 ℃ to 28 ℃, with relative humidity <75%. Normally,

accuracy specifications take the form of: ±([% of Reading]+

[number of Least Significant Digits])  

 

ACCESSORIES 

Test Lead; Temperature probe; Battery; Users Manual; Holster

DC Voltage:

Range

Resolution

Accuracy

400mV

0.1mV

±(1.0%+5)

4V

1mV

 

±(0.8%+3)

40V

10mV

400V

100mV

250V

1V

±(1.0%+5)

Input Impedance:the 400mV range:>1000MΩ

                           the other ranges:10MΩ

Max.Permitted Input:250V DC or AC

AC Voltage 

Range

Resolution

Accuracy

4V

1mV

 

±(1.0%+5)

 

40V

10mV

400V

100mV

250V

1V

±(1.2%+5)

Input Impedance: 10MΩ

Max.Permitted Input:250V DC or AC

Frequency Range:40Hz ~400Hz

Response:Average,calibrated in rms of sine wave.

DC Current 

Range

Resolution

Accuracy

400   uA

0.1  uA

 

 

±(1.2%+3)

 

4000 uA

1     uA

40     mA

10   uA

400   mA

100 uA

4       A

1     mA

±(1.8%+3)

10     A

10   mA

±(2.0%+5)

Overload Protection:

For”mA”jack inputs:Fuse,500Ma/250V,fast action,

For”10A”jack inputs:Fuse,10A/250V,fast action

Max.Input Current:10A(For inputs>5A:

measurement duration<10secs,interval>15minutes)

Max.Voltage Drop:400Mv

AC Current 

Range

Resolution

Accuracy

400uA

0.1uA

 

 

±(1.2%+3)

 

4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(1.8%+3)

10A

10mA

±(2.0%+5)

Overload Protection:

For "mA degree C" jack inputs: Fuse, 500Ma/250V, fast action

For "10A" jack inputs: Fuse, 10A/250V, fast action

Max. Input Current: 10A(For inputs>5A: measurement duration <10secs, interval >15minutes)

Max. Voltage Drop: 400MV

Frequency Range: 40Hz~400Hz

Response: Average, calibrated in rms of sine wave.

RESISTANCE 

Range

Resolution

Accuracy

400 Ω

0.1 Ω

±(1.0%+5)

4    kΩ

1    Ω

 

 

±(1.0%+3)

 

40  kΩ

10  Ω

400 kΩ

100Ω

4     MΩ

1    kΩ

40   MΩ

10  kΩ

±(2.0%+5)

Overload Protection: 250V DC/AC

Open Circuit Voltage: about 0.25V

FREQUENCY

Range

Resolution

Accuracy

10Hz

0.01Hz

±(1.0%+3)

100Hz

0.1Hz

 

±(0.8%+3)

1kHz

1 Hz

10kHz

10 Hz

100kHz

100 Hz

±(1.0%+3)

200kHz

1kHz

>200kHz

 

Not specified

Input voltage:1 Vrms~20 Vrms

Overload Protection:250VDC/AC

CAPACITANCE(use Relative mode) 

Range

Resolution

Accuracy

4     nF

0.001nF

±(4.0%+5)

40   nF

0.01  nF

400 nF

0.1    nF

4     uF

1       nF

40   uF

10     nF

100 uF

100   nF

±(8.0%+5)

Overload Protection: 250V DC/AC 

TEMPERATURE 

Range

Resolution

Accuracy

-20℃~400℃

0.01℃

±1.5%

±3℃

400℃~1000℃

1℃

±2.0%

±3℃

Overload Protection: Fuse, 500Ma/250V, fast action

DUTY CYCLE 

Range

Resolution

Accuracy

5%~95%

0.1%

1Hz~10kHz:±(2.0%+5)

>10kHz: not specified

Input Voltage: 3Vp-p~10Vp-p

Overload Protection: 250V DC/AC 

ELECTROMAGNETIC RADIATION 

Range

Resolution

Accuracy

400mG

0.1mG

1Hz~10kHz:±(2.0%+5)

4000mG

1mG

±(5%+3) at 50Hz/60Hz

Frequency Scope:40~400Hz(Single axis measurements only)

1 Tesla=1000Gauss; 1Gauss=1000 Milligauss

 

 

Packaging & Shipping

 Portable case and carton box, please see picture for more detail.

 

Our Services

 

· Working Time: GMT+8 / 8:15 AM ~ 17:15PM from Monday to Saturday
· Please contact us,if you have any questions. We will reply you within 24 hours

 

Company Information

 Zhangzhou Eastern technology Group was set up in1993.it is a "State High and New Technology Enterprise " Which specializes in research,manufacture and sales of test & measurement instrpment. the products are expoted to more than 70 countries word-wide,it is one of biggest manufacturers of test & measurement instruments ih China. It has undertaken more than 20 national &provincial projects, and obtained more than 100 national patents. It gets ahead in technology and products, and provides worldwide customers with cost-effective test & measurement instruments.

Packaging Details