Mixed viscosity:
1000-2000
Mixture density:
1.45
Gel time:
40 min 25℃
curing time:
80/1.5 or 25/10 ℃/hr
hardness:
80 Shore D
conductivity factor:
0.4 W/mK
expansion coefficient:
44 μm/(m,℃)
water absorption:
<0.1 24h 25℃ %
dielectric strength:
>20 kV/mm 25℃
Loss factor:
0.014 (1MHz)(25℃)
Packaging & Delivery
Packaging Details:
25 kg /set; 5kg / set; 1kg/ set
We can also packing Avoid-knock Anti-flame Glue For Television as your requirement.
Delivery Detail:
Within 25-30 days upon receipt of your L/C or 30% deposit

Specifications

Avoid-knock Anti-flame Glue For Television is one of our most popular products.Against moisture, dirt and other atmospheric...

Description:

ZR112 Avoid-knock Anti-flame Glue For Television is a room temperature/heating curing epoxy resin glue. ZR112 is used for design, protection of the potting need high strength or confidential electronic products.

ZR112 epoxy potting materials without heating can cure. 4:1 (weight ratio) completely mixed part A and part B, form protection in a period of curing time.

 

After curing glue has the following characteristics:

Against moisture, dirt and other atmospheric composition

High strength

Has confidential role   

Solvents, no cure by-products

Fireproof performance

Have stable mechanical and electrical properties between -45°C-120°C

 

Conventional performance:

test item

testing standard

unit

A

B

Outside view

visual inspection

---

black viscous liquid

Brown liquid

viscosity

GB/10247-2008

mPa·s(25°C)

10000-25000

100-150

density

GB/T 13354-92

g/cm3(25°C)

1.55

1.14

 

Operation process:

test item

unit

value

mixture ratio

weight ratio

100:25

mixture ratio

volume ratio

100:34

Mixed viscosity

mPa·s(25°C)

1000-2000

Mixture density

g/cm3(25°C)

1.45

Gel time

min(25°C)

40

curing time

°C/hr

80/1.5 or 25/10

 

Operation time is a quantity of cement with 100 g.

A, B two components in proportion to remove mixing ratio, mixing, vacuum suction bubble in operation period, remove the potting products to casting, such as potting product is too big, suggest points potting, then according to The Times curing(80°C/90min or 25°C/10hr)

 

Operation caution:

Agent A place for a long time, maybe produce precipitation, mix part A and B access should be paid attention to save after sealing.

Mixing should pay attention to the same direction, otherwise, it will stir with too much bubble; Borders and the bottom of the container sizing material should also stir well, can appear otherwise stir caused by uneven local not curing phenomenon. 

Casting the product vacuum pumping, remove again bubble can improve after curing products comprehensive performance.

Temperature is too low will lead to curing speed partial slow, heat cure advice; Potting thickness more than 2 cm above 80 °C not directly in the curing, lest cause explosive together.

This glue curing exothermic reaction, match the process as the quantity of cement can affect the operation, so the length of time with 100 g resin content of operation time is only a reference time.

  

Typical performance: 

test item

testing standard

Unit

value

hardness

GB/T 531.1-2008

Shore D

80

conductivity factor

GB/T 10297-1998

W/mK

0.4

expansion coefficient

GB/T 20673-2006

μm/(m,°C)

44

water absorption

GB/T 8810-2005

24h,25°C,%

<0.1

flame retardant rating

UL-94

3mm,105°C

V-0(E315820)

dielectric strength

GB/T 1693-2007

kV/mm(25°C)

>20

Loss factor

GB/T 1693-2007

(1MHz)(25°C)

0.014

dielectric constant

GB/T 1693-2007

(1MHz)(25°C)

3.53

volume resistance

GB/T 1692-92

(DC500V)Ω· cm

1.2×1015

Remark:All the above data come from 25 °C and 55% RH glue curing conditions after 7 days.

 

Packing:

25 kg /set; 5kg / set; 1kg/ set

 

Storage and transportation:

Part A and part B need to avoid light, heat, save after sealed. (Can be used as the non-dangerous goods transport and storage)

Shelf life Agent A: 1 year, Agent B: 6 months(25°C)

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date

Send your message to this supplier

Not exactly what you want? 1 request, multiple quotations Get Quotations Now >>
You May Like:
aisn-detail010185203196