Electronic Test and Measurement Instrument, 3P3W Active & Reactive Power Transducer/current transducer price

FOB Reference Price:Get Latest Price
1 Piece/Pieces (Min. Order)
Supply Ability:
1000 Piece/Pieces per Month
Port:
Beijing/Shenzhen/Shanghai
Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
GFUE
Model Number:
FUD-P3-Q3
Usage:
Level Sensor
Theory:
Resistance Sensor
Output:
Switching Transducer
FUD-P3-Q3:
3P3W Active & Reactive Power Transducer
Standard:
GB/T 13850-1998, IEC688:1992
Accuracy:
Accuracy
Consumption:
≤5VA
Accutacy drift:
Annual Variation < 0.2%
Insulation Voltage:
Insulation Voltage
Insulation Resistance:
≥20MΩ (DC500V)
Surge voltage:
Surge voltage
surge voltage:
≤350ms
Input Range:
AC 0~5A ,AC 0~500V(Optional), 50/60Hz
Packaging & Delivery
Packaging Details
standard export carton
Delivery Time
7 days from receipt of payment

Specifications

1.Adopted SCM technique; excellent stability.
2.Delivering the direction of measured power accurately.

Function & Feature

Adopted SCM technique; excellent stability.

Delivering the direction of measured power accurately.

Applicable for active/reactive power measurement in 3P3W.

The product is customized for multi-quantity-combined transducer of current, voltage, power and all quantity measurement in 3P3W, RS485 port support.

 

Model Description

 

FUD-Type-Input-Power Supply-Output

Type

P3: 3P3W Active Power Transducer

Q3: 3P3W Reactive Power Transducer

PQ3: 3P3W Active & Reactive Power Transducer

AC Input

V1: 100V, V2: 0~220V, V3: 270V, V4: 400V

A1: 0~1A, A2: 0~5A.

Power Supply

P1: AC110V±10%, P2: AC220V±15%,

P3: AC110V~330V.

DC Output

O1: 0~20mA, O2: 0~±20mA, O3: 4~20mA,

O4: 4~12~20mA, O5: 0~1V, O6: 0~±1V,

O7: 0~5V, O8: 0~±5V, O9: RS485.

Example 1: FUD-P3-V1-A2-P2-O8

FUD Series 3P3W Active

Power Transducer

Input: AC100, ±5A , ±866W

Power Supply: AC220V±15%

Output: DC0~±5V

Example 2: FUD-PQ3-V1-A2-P2-O8

Details: FUD Series 3P3W Active and

Reactive Power Transducer

Input: AC100V, ±5A , ±866W(var)

Power Supply: AC220V±15%

Output: DC0~±5V

Please check the Type, Input range, Output range and Power supply at your order.

 

Technical Index

 

Standard

GB/T 13850-1998, IEC688:1992

Accuracy

0.2%, 0.5%

Consumption

≤5VA

Accutacy drift

Annual Variation < 0.2%

Insulation Voltage

AC 2kV/min.1mA (Between Input ~ Output / Power)

Insulation Resistance

≥20MΩ (DC500V)

Surge voltage

5KV (Peak Value), 1.2/50μs

Response Time

≤350ms

Input Range

AC 0~5A ,AC 0~500V(Optional), 50/60Hz

Absorbed Power

Per phase Voltage:≤0.5VA/100V

Per phase Current:<0.1VA/5A

Overload

Current: 2 times continuous,30 times /1s .Voltage: 2 times continuous

Load Resistance

Current output: RL≤650Ω

Voltage output: RL≥2kΩ

Working environment

Temperature: -10~50°C

RH: 20~90%, Without condensation

Storage conditions

Temperature: -40~70°C

RH: 20~95%, Without condensation

Installation

35mm DIN Sliding-way or M4 screws

Dimension

110mm×75mm×120mm