HS-60-24 60w 24v power supply,24v dc power supply,power supply 24v

FOB Reference Price:Get Latest Price
50 Piece/Pieces (Min. Order)
Supply Ability:
60000 Piece/Pieces per Month
Port:
Shenzhen
Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
GHDIDZ
Model Number:
HS-60-24
Output Power:
51 - 100W
Output Type:
Single
Input Voltage:
220V
Output Voltage:
24v
Output Frequency:
50/60HZ
Output Current:
2.5A
Type:
HS-60-24-power supply 24v
AC input current:
0.9A/230VAC
Efficiency:
84%
Cold start current:
36A/230V
Leakage current:
<1mA/240VAC
Over load protection:
105%~135%rated output power start the over load protection
Weight/Packing:
0.27kg/60PCS/16.2kg
size:
111*78*36mm
Certificate:
CE FCC RoHS
OEM Service:
yes
Packaging & Delivery
Packaging Details
one piece in a box and 60 boxes to a carton,
Size(cm):38*33*23
Delivery Time
7~10 days delivery after receive payment

Hello Dear customers , welcome to visit our website, if any power supply question, please don't hesitate to contact us, we are very glad to answer you. thank you.

 

HS-60-24 60w 24v power supply,24v dc power supply,power supply 24v    

Model

HS-60-12

HS-60-15

HS-60-24

 

Output

DC output voltage

12V

15V

24V

Output voltage tolerance

±2%

±1%

±1%

Rated output current

5A

4A

2.5A

Output current

0~5A

0~4A

0~2.5A

Output power

60W

60W

60W

Ripple and noise

100mVp-p

100mVp-p

150mVp-p

DC adjustable range

±10%

±10%

±10%

Setup rise hold up time

200ms,100ms,20ms

 

Input

Input voltage range

100~264VAC 47~63Hz,240~370VDC

AC input current

0.9A/230VAC

Efficiency

80%

80%

84%

AC inrush current

Cold start current 36A/230V

Leakage current

<1mA/240VAC

Protection

characteristic

Over load protection

105%~135%rated output power start the over load protection

 

Protection mode : Hiccup mode ,auto-recovery

Over-voltage protection

 

 

Environment

Working temperature

10°C~+60°C;20%~90%RH(please refer to the Load deduction curve)

Security

Withstand voltage

Between input and output::1.5KVACThe input and ground : 1.5KVACThe output and ground :0.5KVAC

Insulation resistance

Between input and output:The input and ground, the output and ground: 100M 0hms /500VDC

 

Others

Weight/Packing

0.27kg/60PCS/16.2kg

 

Remark

  • All parameters at the unspecified condition, should be measured in the 230V input voltage ,at the rated load and 25°C.
  •  Ripple and noise voltage is measured at the end of 20MHz Bandwidth of oscilloscope  12 inch Twisted pair plus 0.1u and 47u.
  • Tolerance is the sum of voltage setting error,voltage regulation rate and current regulation rate.

 

Size Picture