MEANWELL 100W 350mA Constant Current IP67 waterproof Dimmable with PFC function UL/CE/CUL Approval LED Driver HVGC-100-350

FOB Reference Price:Get Latest Price
US $2-8 / Piece | 5 Piece/Pieces (Min. Order)
Supply Ability:
100000 Piece/Pieces per Month
Port:
Shanghai or Shenzhen
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Jiangsu, China (Mainland)
Brand Name:
MEANWELL
Model Number:
HVGC-100-350
Output Power:
100W
Output Type:
Single
Input Voltage:
200~480VAC;282~679VDC
Output Voltage:
170~285V
Output Frequency:
0
Output Current:
350mA
led power supply size:
234*68*38.8mm (L*W*H)
Power supply's Protections:
Shut down o/p voltage with auto-recovery or re-power on to recovery
Power supply's SAFETY STANDARDS:
UL8750, IP65 or IP67 approved ; Design refer to UL60950-1
Cooling Type:
By free air convection
LED Power's EFFICIENCY (Typ.):
92%
LED Power's OVER CURRENT:
95 ~ 108%
The Switching Power' FREQUENCY RANGE:
47 ~ 63Hz
THE WORKING TEMP.:
-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
THE WORKING HUMIDITY:
20 ~ 95% RH non-condensing
Switching Power's VIBRATION:
10 ~ 500Hz, 5G 12min./1 cycle, period for 72min. each along X,Y,Z axes
Packaging & Delivery
Packaging Details
meanwell HVGC-100-350 1.18Kg; 12pcs/15.2Kg/0.74CUFT
Delivery Time
Within 3 days

Specifications

Single Output With Wide input Range
High efficiency up to 91%
Constant current
PFC,Dimming function
5 years warranty

 

MEANWELL  100W 350mA Constant Current IP67 waterproof Dimmable with PFC function UL/CE/CUL Approval LED Driver HVGC-100-350

 

Features :

  • Single Output With Wide input Range
  • High efficiency up to 91%
  • Constant current design
  • PFC,Dimming function
  • 5 years warranty  

 

 

MODEL

HVGC-100-350

OUTPUT

RATED CURRENT

350mA

RATED POWER

99.75W

RIPPLE & NOISE (max.)? Note.2

3Vp-p

VOLTAGE ADJ.RANGE?

210 ~ 350mA

CURRENT ADJ.RANGE

Can be adjusted by internal potential meter or through output cable

SETUP, RISE TIME

4000ms, 3000ms at full load 440VAC / 347VAC ; B type 5000ms, 500ms at 95% load 440VAC / 347VAC

HOLD UP TIME (Typ.)

12ms at full load 440VAC / 347VAC

INPUT

VOLTAGE RANGE

200 ~ 480VAC 282VDC ~ 679VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF>= 0.95/440VAC PF >=0.98/347VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load

EFFICIENCY (Typ.)

92%

AC CURRENT (Typ.)

0.32A / 347VAC 0.25A / 440VAC

INRUSH CURRENT (Typ.)

COLD START 75A / 440VAC

LEAKAGE CURRENT

<0.75mA / 440VAC

PROTECTION

OVERCURRENT NOTE.4

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

305 ~ 315V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

100 10 (RTH2)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

SHORT CIRCUIT

Constant current limiting, recovers automatically after fault condition is removed

ENVIRO NMENT

WORKING TEMP.

-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY &EMC (Note 4)

SAFETY STANDARDS

UL8750, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13

WITHSTAND VOLTAGE?

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH

HARMONIC CURRENT

Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3

EMS IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A

OTHERS

MTBF

Khrs min. MIL-HDBK-217F (25 )

DIMENSION

234*68*38.8mm (L*W*H)

PACKING

Kg

NOTE

1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Derating may be needed under low input voltages. Please check the static characteristics for more details. 4. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.