• Sourcing Solutions
  • Services & Membership
  • Help & Community
About 11819 results:
Switching Power Supply (7513)
Add to My Favorites Added to My Favorites

Mean Well 60W 12V Switching Power Supply 60W 12V led driver/led driver dimmable//waterproof led power supply 12v 60w

FOB Reference Price:Get Latest Price
US $10 - 32 / Piece | 1 Piece/Pieces (Min. Order)
Supply Ability:
80000 Piece/Pieces per Month
Port:
Shanghai or Shenzhen
Seller Support:
Payment protection
On-time shipment
Product quality protection
Payment:
More

Quick Details

Place of Origin:
Jiangsu, China (Mainland)
Brand Name:
Meanwell
Model Number:
LPF-60D-12
Output Power:
60W
Output Type:
Single
Input Voltage:
90 ~ 305VAC
Output Voltage:
12V
Output Frequency:
47~63Hz
Output Current:
5A
LPF-60D-12:
60W Single Output Switching Power Supply

Packaging & Delivery

Packaging Details: 0.45Kg; 32pcs/15.4Kg/0.93CUFT
Delivery Detail: 2~3 days

 

Products Pictures

 

 

Specifications

 

 

MODEL

LPF-60D-12

OUTPUT

DC VOLTAGE

12V

CONSTANT CURRENT REGION Note.4

7.2 ~ 12V

RATED CURRENT

5A

RATED POWER

60W

RIPPLE & NOISE (max.)         Note.2

150mVp-p

VOLTAGE TOLERANCE       Note.3

±4.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±2.0%

SETUP, RISE TIME            Note.7

1000ms, 80ms / 115VAC at full load         1000ms, 80ms / 230VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC   16ms/115VAC at full load

INPUT

VOLTAGE RANGE          Note.5

90 ~ 305VAC 127 ~ 431VDC

FREQUENCY RANGE 

47~63HZ

POWER FACTOR (Typ.)

PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

EFFICIENCY (Typ.)

86%

AC CURRENT(Typ.)

0.8A / 115VAC         0.4A / 230VAC         0.32A / 277VAC

INRUSH CURRENT (Typ.)

COLD START 55A(twidth=270us measured at 50% Ipeak) at 230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER CURRENT   Note.4

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE  

15 ~ 17V

Protection type : Shut down and latch off o/p voltage, re-power on to recover

OVER TEMPERATURE

90°C±10°C (RTH2)

Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-40~ +70°C(Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80°C, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 ~ 50°C)

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY&EMC

SAFETY STANDARDS   Note.6

UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13

approved ; design refer to UL60950-1, TUV EN60950-1

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25°C/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C( ≥60% load),EN61000-3-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A

QTHERS

MTBF

396.7K hrs min.MIL-HDBK-217F (25°C)

DIMENSION

162.5*43*32mm (L*W*H)

PACKING

0.45Kg; 32pcs/15.4Kg/0.93CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

5. Derating may be needed under low input voltages. Please check the static characteristics for more details.

6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.

7. Length of set up time is measured at cold first start, Turning ON/OFF the power supply may lead to increase of the set up time.

8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Business Procedure

 

 

Advantages

 

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date

Send your message to this supplier

Not exactly what you want? 1 request, multiple quotations Get Quotations Now >>
Trade Assurance
China (Mainland) | Trading Company
Transaction Level:
Supplier Assessments:
17 Transactions 8,000+
The supplier’s transactions conduted via Alibaba.com in the past 6 months.
aisndetail010176175120