Pediatric,Neonatal six parameters ,ECG,SPO2,RESP,TEMP,NIBP.PR 7''patient monitor

FOB Price: US $10 - 100 / Set Get Latest Price
Min.Order Quantity: 1 Unit/Units
Supply Ability: 5000 Unit/Units per Month
Port: Shenzhen
Payment Terms: L/C,T/T
Add to My Favorites

Quick Details

Type:
Medical Micro-Devices
Brand Name:
JUMPER
Model Number:
BF-800A 7''
Place of Origin:
Guangdong China (Mainland)
working Temperature Range:
(5 ~ 40)°C
working Relative Humidity:
≤ 80 %
working Air pressure range:
(86~106)kPa
working Power voltag AC:
100 V -240V
working Power frequency:
50/60Hz.

Packaging & Delivery

Packaging Detail: 41*27*34 7kg/carton
Delivery Detail: within 10 days upon receipt of payment

Specifications

patient monitor portable
1.Anti-ESU, anti-defibrillator
2Arrhythmia analysis, ST calculation
3option:printer,IBP ETC

 

 7 inches multi-parameter patient monitor portable 

Technical Specifications

B.1 Basic parameters

ECG, RESP, NIBP, SpO2, PR, TEMP, Optional: Printer, IBP, FiCO2, EtCO2,.

B.2 Average working time without malfunction

   Average working time without malfunction: ≥ 1000 hours.

B.3 Normal working environment

a)    Temperature Range: (5 ~ 40)°C

b)    Relative Humidity: ≤ 80 %

c)    Air pressure range: (86~106)kPa

d)    Power voltag AC: 100 V -240V

e)    Power frequency: 50/60Hz.

g)    Battery: d.c 10.2 V ~ d.c 12.6 V

B.4 Safety requirements and classifications

  1. Electric shock type: type I equipment with inside power supply and internal power supply.
  2. Electric shock degree: all application parts are BF type, except ECG and TEMP which are CF type.
  3. Harmful liquid material proof degree: ordinary equipment (no seal against liquid).
  4. Disinfection: follow manufacturer’s recommended methods.
  5. Safety on flammable gas: not suitable to use where flammable gas is present.
  6. Input power: no bigger than 80VA.
  7. The monitor has applicable
  8. The monitor has network, display, printer, and USB ports.
  9. Power supply is AC 100V-240V 50/60 Hz
  10. The monitor is a continual working system.

 

B.5 ECG

(HR)heart rate:

a) measurement range: 30 bpm ~ 300 bpm

b)        measurement accuracy: 1 bpm or ±1%, take the bigger one.

Settings and allowable tolerance for HR alarm:
   Upper limit: 60 bpm
~ 300bpm,allowable tolerance ±10%
   Lower limit:
30 bpm~ 200bpm,allowable tolerance ±10%

HR alarm response time: <12s

ECG noise: ≤ 30μV
ECG frequency response:

Monitoring mode: (0.5 ~ 40)Hz (+0.4dB -3Db)

Diagnostic mode: (0.05 ~ 100)Hz (+0.4dB -3dB)

ECG input loop current: ≤0.1μA.

ECG display sensitivity: Step-type

×1 step   10mm/mV         tolerance less than ±5%
×1/2 step   5mm/mV         tolerance less than ±5%
×1/4 step   2.5mm/mV       tolerance less than ±5%
×2 step   20mm/mV         tolerance less than ±5%

Display sensitivity:

a)         Time shift: initiate at the baseline after 15min's energizing.The shift scope of the baseline is not beyond 5mm after 60min's.

b)        Temperature shift: the scope is from 5°C --40°C.The shifting average of baseline should be no more than 0.5mm/°C.

c)         The shift of waved baseline of supply voltage should be no more than 1mm. The sensitivity changes should be displayed ±10%

d)        The poling voltage at ±300mv is added between positive electrode and N electrode, negative electrode and N electorde. The changes of sensitivity error should be displayed ±5%

Scanning velocity and error

Scanning velocity: 6.25 mm/s, 12.5 mm/s, 25 mm/s, and 50 mm/s.

Scanning velocity error: ±10%.

Input impedance: The impedance between positive electrode and the N electrode, between thecathode and the N electrode is no smaller than 5MΩ.

Module signal suppression ability: 89 dB

Time constant: Diagnostic mode 3.2 seconds

             Monitoring mode 0.3 seconds

 

B.6 NIBP

Measurement range

a) Adult    Systolic blood pressure(SBP): (5.3 ~ 36.0)kPa,or(40 ~270 )mmHg

Diastolic blood pressure(DBP): (2.7 ~ 26.7)kPa,or(20 ~200 )mmHg

Mean average pressure(MAP): (4.0 ~ 29.3)kPa,or(30 ~220 )mmHg.

b) Pediatric Systolic blood pressure(SBP): (5.3 ~ 24.0)kPa,or(40 ~180)mmHg

Diastolic blood pressure(DBP): (2.0 ~ 21.3)kPa,or(15 ~160)mmHg

Mean average pressure(MAP): (2.7 ~ 22.7)kPa,or(20 ~170)mmHg.

c) Neonate   Systolic blood pressure(SBP): (4.0 ~ 18.7)kPa,or(30 ~140)mmHg

Diastolic blood pressure(DBP): (2.0 ~ 13.3)kPa,or(15 ~100)mmHg

Mean average pressure(MAP): (2.7 ~ 15.3)kPa,or(20 ~115)mmHg.

 

Measurement accuracy: ±0.4 kPa (3 mmHg) or ±2%,take the bigger one.

Display unit: KPa or mmHg.

B.7 IBP

Measurement range: (- 5.33 ~ + 44.0)kPa,or(-40 ~ + 330 )mmHg

measurement accuracy: 4 % or ± 0.5 kPa,take the bigger one.
display unit: kPa or mmHg are electable.

B.8 RR

Measurement range: (0 ~ 120 )bpm Measurement accuracy: ±1 bpm or ±5 %,take the bigger one.

B.9 TEMP

Measurement range: 25°C~ 45°C

Measurement accuracy: ±0.2°C

Response time: ≤3 min.

B.10 SpO2

Measurement range: 0 %~ 100%

Measurement accuracy: ±2% during 70 %~ 100%, not required during 0 %~ 69%.

B.11 PR

Measurement range: 30 bpm ~ 250bpm

Measurement accuracy: 1 bpm or ±2%. Take the bigger one.

B.12 CO2

Measurement range:

FiCO2 and Et CO2:   (0 ~ 10.0)%

measurement accuracy:

FiCO2 and Et CO2: 0~5% ±0.2%

5.1%~10%±8% of reading

>10% ±10% of reading

 

Health is passed on here!

 

INVITATION

 

 

Warmly welcome to booth (NO. 2L25 ) of Beijing Fuxinghua Group IN Africa Health 2014(From May 29th to May31st)

Not exactly what you want? 1 request,multiple quotations Get Quotations Now >>
Beijing Fuxinghua Group, founded in 1996, is a joint-stock enterprise which have been engaged in the international and domestic trade many years in the field of medical products such as hemorrihoids theraphy device ,fetal doppler,patient monitor,pulse oximeters and another line hospital beds.

Our company continues to explore overseas markets and establish OEM relationship. Quality, innovation, sincerity, cooperation, is the consistent pursuit of BEIJING FUXINGHUA GROUP. Recently, our new ... View detail

Basic Information

Product/Service (We Sell): Medical Bath Treatment Device,Medical product,Fetal Monitor,Patient Monitor,Fetal Doppler  
Number of Employees: 301 - 500 People  

Trade & Market

Main Markets: Oceania
Eastern Europe
Central America
South America
Southeast Asia
Eastern Asia
Northern Europe
Domestic Market
Africa
Western Europe
Southern Europe
Mid East
North America
South Asia
Total Annual Sales Volume: US$2.5 Million - US$5 Million  
Export Percentage: 51% - 60%  

Factory Information

Factory Size (Sq.meters): 50,000-100,000 square meters  
Factory Location: Huairou District, Beijing  
Number of Production Lines: 10  
Number of R&D Staff: 41 - 50 People  
Number of QC Staff: 21 - 30 People  
Management Certification: GMP   GMP  
Contract Manufacturing: OEM Service Offered   Design Service Offered   Buyer Label Offered  

Supplier Assessment Report

Do you want to know more about this company before you make a deal? Request an Assessment Report.
Supplier Assessment Reports are detailed on-line reports about the supplier's capabilities. It helps you get all the information you need to trade confidently with suppliers.

Send your message to this supplier

Sourcing Products & Suppliers on Alibaba.com

Search Products
Enter the product you are looking for in the Search Bar and click Search
Contact Suppliers
Click Contact Now to send an inquiry or I’m online, Chat now to chat online
Check Messages
Check quotes & messages from suppliers in your email inbox or Message Center
China (Mainland) | Contact Details
Experience: Established 1996 , 10 years OEM

Communicate with Supplier:

Mr. NING WANG
Mr. NING WANG:
What can I do for you?
Not exactly what you want?
1 request,multiple quotations Get Quotations Now >>
You May Like: