About 15 results:
Other Lab Supplies (1)

microbial Culture Media, Columbia Agar Base for food and pharmacetical

FOB Price: Get Latest Price
Min.Order Quantity: 10 Kilogram/Kilograms
Supply Ability: 10000 Kilogram/Kilograms per Month
Port: Guangzhou,Shenzhen
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,alipay
Add to My Favorites

Quick Details

Classification:
Other
Brand Name:
HKM CHINA
Model Number:
HCM088
Place of Origin:
Guangdong China (Mainland)
color:
light yellow
Reagent grade:
Biochemical Reagent
Physical behavior:
Powder
type:
Columbia Agar

Packaging & Delivery

Packaging Detail: Packing material:Packed in plastic bottles with plastic film wrapped Capacity:500G/bottle, 20 bottle/ carton Carton size :54.5*34.5*21CM
Delivery Detail: within two weeks after order

 

 

 

 

 

Product Description

 PRODUCT:

1.brand:HKM CHINA

   FROM:Guangdong,CHINA.

2.Usage: A multi-purpose medium suitable for the cultivation of fastidious organisms.

 3.Huankai is one of biggest manufacturer in China. HKM media is famous for its good quality and good package.

4.Storage:Keep container tightly closed,store in a cool ,dry place,away from bright light.

5.packing specification

500grams per bottle

 

Certification:

 

 

Packaging & Shipping

 

Package:Packing material:Packed in plastic bottles with plastic film wrapped

                    Capacity:1liter/bottle, 20 bottle/ carton Carton size :51*33*17CM

 

 

 

Our Services

1.Offering Free Sample for Testing .

2.R & D team to provide technical support.

3.Provide packaging, labeling OEM customization.

 

 

Company Information

 

Founded in 1993, Guangdong Huankai Microbial Sci. & Tech. Co.,Ltd. is the most important manufacturing and R&D base in the field of detection and control of food safety in China. It is an high-tech corporation belonging to The Guangdong Institute of Microbiology.  Through undertaking National and Provincial Level Food safety projects it has won 12 National and Guangdong Provincial level Awards, and has been awarded 33 National patents. In recent years it has been actively participating in the formulation of National and Trading microbial hygiene standards for food and mineral water.

 

Huankai has always been devoted to monitoring biological safety and controlling the development, production and management of products. At the present it produces microbial monitoring products on a large scale, consisting of 3 large ranges, which amount to nearly 600 varieties of product, including: a series of rapid water quality detection products, highly efficient and environmentally friendly disinfectants as well as biologocial safety laboratory equipment. All of which are largely used in provinces and cities around China, Hong Kong, Macao, Taiwan, as well as other East Asian Countries. After 10 years of development, Huankai has already become the largest manufacturer of microbial monitoring products in China, and the largest manufacturer of industrial cleaning detergent in South China.

 

With its R&D production bases located in Guangzhou Science City Guangdong Advanced Bio-Tech Demonstration Zone, Huankai now has industry leading GMP workshops producing microbial detection products as well as the largest production line in South China for highly efficient environmentally friendly industrial cleaning detergents used in the food and medical sector. These advanced conditions are helping Huankais speedy development.

 

 

 

FAQ

 

Q1:

Sometimes color of dehydrated culture media  between batches have subtle differences,would this affect test results?

A1:The source and storage conditions of raw material is different ,so there may be a slight difference in color, which is a normal phenomenon. Products from our company have to undergo a rigorous inspection and sensory biology verification before sale, to ensure that all the indicators characteristics of the product is under enterprise standard to the extent permitted, not affect the test results.

 

Q2:

After pouring the liquid medium on the plate , medium seems hard to clot or coagulation time is longer, is it some problem with product quality?

A2: The reason may be:

The required hydration in the preparation process have not been done completely .That is to say   distilled water is not boil sufficiently to dissolve agar. Because agar proportion, easily settle in the bottom of the bottle, if not fully shaken after high-temperature sterilization, it will lead to uneven upper agar culture gene content and difficult to set.

 

Q3:

Why some colonies of E. coli chromogenic medium color not shown above, but also confirmed through biochemical tests for E. coli (false negative)?

A3: E. CHROMOGENIC medium is based on the principle of specific enzyme of E. coli and design, 94% of E. coli have β- glucuronidase enzyme, with the chromogenic enzyme substrate medium role in the formation of blue-green colonies. And about 4% of the E. coli does not have β- glucuronidase enzymes, including concern O157: H7 Escherichia coli. Therefore, these E. coli can not be displayed on the color characteristic of E. coli chromogenic medium,it is possible of false-negative on the chromogenic medium. However, the traditional medium of the same can not avoid the problem of false negatives, such as: no gas or slow ferment lactose intolerance may also strain 44.5 ℃ false negatives in the conventional medium. For this small part of the E. coli can be detected using other methods.

 

Q4:

During anaerobic or micro-aerobic culture, is it necessary to remove gas bag from package? How to use oxygen indicator?

A4: During anaerobic or micro-aerobic culture, using method of gassing agent should be done according to the manufacturer's instructions. Remove the paper bag from the plastic packaging, but do not cut the paper bag. Torn the outer packaging of oxygen indicator then it can be used.

Not exactly what you want? 1 request,multiple quotations Get Quotations Now >>
Guangdong Huankai Microbial Sci. & Tech. Co., Ltd. was founded in 1993, as a national hi-tech enterprise under Guangdong Institute of Microbiology of Guangdong Provincial Academy of Sciences, and was certified by ISO9001:2000 quality management system in April 2004.

Our research and development base is located in the Chinese Academy of Science Hi-Tech Industry Demonstration Base in the beautiful Guangzhou Science City. Huankai has many advanced production lines and modern laboratories. ... View detail

Basic Information

Product/Service (We Sell): Air Sampler,Disinfection Liquid,Water Test Agent  
Number of Employees: 101 - 200 People  

Trade & Market

Main Markets: Central America
South Asia
North America
South America
Eastern Europe
Mid East
Southeast Asia
Africa
Total Annual Sales Volume: US$5 Million - US$10 Million  
Export Percentage: 11% - 20%  

Factory Information

Factory Size (Sq.meters): 5,000-10,000 square meters  
Factory Location: No.788, Shenzhou Road, Guangzhou, China  
Number of Production Lines: 10  
Number of R&D Staff: 11 - 20 People  
Number of QC Staff: 5 - 10 People  
Contract Manufacturing: OEM Service Offered   Design Service Offered   Buyer Label Offered  

Supplier Assessment Report

Do you want to know more about this company before you make a deal? Request an Assessment Report.
Supplier Assessment Reports are detailed on-line reports about the supplier's capabilities. It helps you get all the information you need to trade confidently with suppliers.

Send your message to this supplier

Sourcing Products & Suppliers on Alibaba.com

Search Products
Enter the product you are looking for in the Search Bar and click Search
Contact Suppliers
Click Contact Now to send an inquiry or I’m online, Chat now to chat online
Check Messages
Check quotes & messages from suppliers in your email inbox or Message Center
China (Mainland) | Manufacturer, Trading Company | Contact Details
Experience: Established 1993 , 12 years OEM

Communicate with Supplier:

Mr. Aaron Dave
Mr. Aaron Dave:
What can I do for you?
Not exactly what you want?
1 request,multiple quotations Get Quotations Now >>