| Conductor Material: | Aluminum |
| Brand Name: | JSC Electrocable works |
| Application: | Industrial |
| Type: | Medium Voltage |
| Place of Origin: | Russian Federation |
| Insulation Material: | PVC |
| Jacket: | PVC |
| Payment Terms: | L/C |
| Minimum Order Quantity: | 5 Piece/Pieces cable drum |
| Supply Ability: | 150 Piece/Pieces per Month |
| Package: | in 20' dry container |
intended for distributing electric power in fixed installations rated for nominal alternating voltages of 0. 66KV and 1 KV 50 Hz
Assembly:
1. Conductor aluminum, single or multiwire, round- or sector-shaped, 1 or 2 class as per GOST 22483.
2. Insulation PVC.
Insulated multiconductor cable conductors carry identification coloring. Neutral conductor insulation is blue. Grounding conductor insulation is in two colors (yellow-green).
3. Twisting Insulated conductors of two-, three-, four-, and five- conductor cables are twisted. Two conductor cables feature conductors of the same area. Three-, four-, and five- conductor cables feature all the conductors of the same area or one conductor (ground or neutral one ) of a smaller area. Nominal areas of neutral conductors (of smaller area) are in accordance with those stated in Appendix on page 51.
4. Jacket PVC, AVVGng cables are sheathed with flameretardant PVC.
Application:
These cables are intended for distributing electric power in fixed installations rated for nominal alternating voltages of 0.66 KV and 1 KV 50 Hz. They are meant for laying inside both dry and wet industrial premises on special trestles, in assemblies as well as for laying outdoors. Cables are not recommended for burying in trenches.
AVVG cables are flameretardant if laid individually.
AVVGng cables are flameretardant if laid in bunches
Technical details:
Type of climatization UHL, , allocation category - 1 and 5 as per GOST 15150-69.
Operating temperature range-500 to +500
Relative humidity of at temperatures of up to +35 oC..up to 98%
Cables shall be laid and installed without preheating at temperatures not lower than -15 oC Minimum bending radius when laid: AVVG single conductor cables 10 outer diameters
AVVGng single conductor cables.15 outer diameters
Multiconductor cables..7.5 outer diameters
Rated frequency50 Hz
Testing alternating current voltage 50 Hz.
For 0.66 KV3 KV
For 1 KV.3.5 KV
Continuously permissible conductor operating heating temperature..+70
Construction lengths for main conductor areas: 1.6 to 16 mm2450 m
25 to 70 mm2 300 m
95 mm2 or greater.200 m
Guarantee service life.5 years from the day of putting into operation
Service life.. 30 years
Tabulated data
OKP codes:
35 2222 11 AVVG cables rated for 0.66 KV
35 3371 52 AVVG cables rated for 1 KV
35 2222 45 AVVGng cables rated for 0.66 KV
35 3371 54 AVVGng cables rated for 1 KV
| Business Type: | Trading Company, Agent |
| Product/Service (We Sell): | FORWARDING, TRADING, BROKERAGE |
| Number of Employees: | Less than 5 People |
| Main Markets: | North America South America Eastern Europe Southeast Asia Africa Mid East Eastern Asia Western Europe |
| Main Customers: | RUSELPROM, Sea Modern Systems, Electrocable Works, Spetsbasalt |
| Total Annual Sales Volume: | Below US$1 Million |
| Export Percentage: | 71% - 80% |
| Total Annual Purchase Volume: | Below US$1 Million |
US$0.90 - 1.16 / Piece
Min. order: 1 Piece
Buy NowUS$0.30 - 0.30 / Meter
Min. order: 100 Meter
Buy Now