Detailed Products description for supersilent diesel generators.
Delivery time for supersilent diesel generators is within around 45days after the order is confirmed
CUMMINS SERIES GENERATOR SETS
50HZ,1500RPM,0.8LAGGING,400/230V ADJUSTABLE
| OLD Genset Model | NEW Genset Model | Prime Power | Standby Power | Engine Model | Shanghai MVC Alternator | DIMENSION LXWXH (mm) | Weight (kg) | ||
| KVA | KW | KVA | KW | Model | |||||
| HBC18 | HCM23 | 20 | 16 | 22.5 | 18 | 4B3.9-G | 1600X830X1200 | 950 | |
| HBC22 | HCM28 | 25 | 20 | 27.5 | 22 | 4B3.9-G | MGA225-20-4S | 1600X830X1200 | 950 |
| HBC26 | HCM33 | 30 | 24 | 32.5 | 26 | 4BT3.9-G | MGA225-24-4S | 1800X830X1200 | 1000 |
| HBC33 | HCM41 | 37.5 | 30 | 41.25 | 33 | 4BT3.9-G | MGA225-30-4S | 1800X830X1200 | 1000 |
| HBC45 | HCM56 | 50 | 40 | 56.25 | 45 | 4BTA3.9-G2 | MGA225-40-4S | 1950X830X1200 | 1100 |
| HBC55 | HCM63 | 56 | 45 | 62.5 | 50 | 4BTA3.9-G2 | MGA225-45-4S | 1950X830X1200 | 1100 |
| HBC64 | HCM80 | 72.5 | 58 | 80 | 64 | 6BT5.9-G2 | MGA225-58-4S | 2150X830X1200 | 1250 |
| HBC77 | HCM96 | 87.5 | 70 | 96.25 | 77 | 6BT5.9-G2 | MGA225-75-4S | 2280X830X1200 | 1350 |
| HBC88 | HCM110 | 100 | 80 | 110 | 88 | 6BT5.9-G2 | MGA270-80-4S | 2280X830X1200 | 1400 |
| HBC100 | HCM125 | 112.5 | 90 | 125 | 100 | 6BTA5.9-G2 | MGA270-90-4S | 2400X950X1300 | 1550 |
| HBC114 | HCM143 | 130 | 104 | 142.5 | 114 | 6BTAA5.9-G2 | MGA270-104-4S | 2400X950X1300 | 1700 |
| HBC132 | HCM165 | 150 | 120 | 165 | 132 | 6CTA8.3-G2 | MGA270-120-4S | 2650X950X1430 | 2100 |
| HBC154 | HCM193 | 175 | 140 | 192.5 | 154 | 6CTA8.3-G2 | MGA270-140-4S | 2650X950X1430 | 2150 |
| HBC165 | HCM206 | 187.5 | 150 | 206.25 | 165 | 6CTA8.3-G2 | MGA270-150-4S | 2650X950X1430 | 2200 |
| HBC176 | HCM220 | 200 | 160 | 220 | 176 | 6CTAA8.3-G2 | MGA270-160-4S | 2650X950X1530 | 2350 |
| HBC200 | HCM250 | 225 | 180 | 250 | 200 | 6LTAA8.9-G2 | MGA270-180-4S | 2800X980X1530 | 2500 |
| HBC220L | HCM275 | 250 | 200 | 275 | 220 | 6LTAA8.9-G2 | MGA270-200-4S | 2800X980X1530 | 2500 |
| HBC220M | HCM275 | 250 | 200 | 275 | 220 | MTA11-G2A | MGA270-200-4S | 2900X1000X1600 | 2800 |
| HBC240 | HCM296 | 271.25 | 217 | 296 | 237 | MTA11-G2A | MGA315-220-4S | 2900X1000X1600 | 2800 |
PERKINS SERIES GENERATOR SET
| OLD Genset Model | NEW Genset Model | Prime Power | Standby Power | Engine Model | Shanghai MVC Alternator | DIMENSION LXWXH (mm) | Weight (kg) | ||
| KVA | KW | KVA | KW | Model | |||||
| P45EM | HPM45 | 40 | 32 | 45 | 36 | 1004G | MGA225-34-4S | 2150X750X1340 | 800 |
| P50EM | HPM50 | 45 | 36 | 50 | 40 | 1004G | MGA225-40-4S | 2150X750X1340 | 820 |
| P65EM | HPM65 | 60 | 48 | 65 | 52 | 1004TG | MGA225-50-4S | 2350X750X1400 | 870 |
| P78EM | HPM78 | 70 | 56 | 77.5 | 62 | 1004TG | MGA225-58-4S | 2350X750X1400 | 920 |
| P100EM | HPM100 | 90 | 72 | 100 | 80 | 1006TG1A | MGA225-75-4S | 2500X750X1500 | 1180 |
| P110EM | HPM110 | 100 | 80 | 110 | 88 | 1006TG2A | MGA270-80-4S | 2500X750X1500 | 1180 |
| P125EM | HPM125 | 112.5 | 90 | 125 | 100 | 1006TAG | MGA270-91-4S | 2700X900X1500 | 1300 |
| P150EM | HPM150 | 135 | 108 | 150 | 120 | 1006TAG | MGA270-120-4S | 2700X900X1500 | 1400 |
ATS SYSTEM
For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can automatic transfer load from Mains power supplying to Emergency power. In normal, when the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets automatically.
SOUNDPROOF CANOPY DESCRIPTION
Standard Accessory:
Steel Weatherproof Canopy
Built In Fuel Tank For 8 Hours Running
Built In Control Panel
Built In Start Battery
Power Output Rapid Insert
Windows For Looking
Air Louver For Intake & Exhaust
Exhaust Gas Silencer
Common Weatherproof Type
Soundproof Type
Container Soundproof Type
Asia steel falls as global auto sales hit slump
What impression you would like to give to your partner?