| Brand Name: | HARSVERT |
| Output Voltage: | 3kV to 11kV |
| Output Power: | >500W |
| Place of Origin: | Beijing China (Mainland) |
| Fob Price: | US$100000-800000China |
| Port: | China |
| Minimum Order Quantity: | 1 Set/Sets |
| Supply Ability: | 800 Set/Sets per Year |
| Package: | 1. CIF foreign sea port price will be special supported. FOB+USD900= CIF 2.Delivery:8-12 weeks (60 days) 3.Warranty: 18 months from the delivery 4 Payment: A. 20% in advance, 80% by 30 Days' credit B. 20% in advance, 80% by 60 Days' credit at 1% additional cost C. 20% in advance, 80% by 90 Days' credit at 2% additional cost. 5 Optional 1: 8% for cell by pass Optional 2: 15% for cell redundancy and cell by pass. For mill application, sizing is required |
| Delivery Time: | within 90 days |
Variable Speed Drive:HARSVERT frequency converter can adjust frequency of power supply to the motor,control speed of pumps or
1. Characteristics of Harsvert frequency converter
High-High voltage resource VFD, direct 3,4.16,6,6.6,10,11kV input, direct 3,4.16,6,6.6,10,11 kV output, no output transformer necessary.
Power factor is 0.95 in 20~100% load, low harmonic current, no power factor compensator or harmonic control device required
Sinusoidal step PWM output wave, no output filter required, can be directly connected to common motor, no harm to the insulation of the cable or motor. Soft start function, no voltage reduction resulted from impact of motor start.
Output waveform of VFD do not bring resonance for motor, torque pulse is less than 0.1%. it can reduce fans surge. VFD has resonance point skip function.
No requirement to output cable. Motor is not influenced by common mode voltage and dv/dt.
Complete microcomputer control, self-detection. VFD can display failure and remote alarm, which is convenient for personnel to solve problem.
Local control and remote control, support Profibus, Modbus, TCP/ IP etc. various communication protocols.
Torque character: 0~50 Hz constant torque, rated torque output, torque step response < 200ms. Up 50 Hz, constant power, maximal torque decreases in inverse proportion to speed.
VFD can stand 35% voltage reduction of electric net and continue working, not trip off.
Technique of cell-cascaded, better output waveform, no special requirement to motor and cable.
Power cell manufactured with IGBT is high in redundancy; technique of self-bypass of power cell; system reconstructs voltage vector when failure power cell quits to operate, enhancing utilization of voltage; ensure 96% of output voltage when single power cell is broken in 8 level series.
Start up again after power failure recovery: when power faults and recovers within set time ( default time: 20s ), VFD will self-start. System searches motor speed automatically to start again without impact, recovering original operation state.
Starts up again during rotating.
Main circuit is linked with controller by optical fiber, which make the system extremely safe and away from electromagnetic disturbance.
Multi-ply rectifier technique, small harmonic, high power factor, up to standard IEEE std 519-1992.
Friendly and easy interface.
Redundancy design for control power source: AC220V or AC380V(three phase four wire) is applicable to HARSVERT VFD and double channel AC 220V at the same time, mutual standby. Double power source auto-turn switch ensure stability of control power source. Furthermore, DC220V, even DC110Vcan be spare power source, realizing mutual standby of AC and DC.
Self-adaption of acceleration and deceleration.
Complete fault monitor circuit, accurate fault alarm protection. Protection including: over voltage, over current, low voltage, phase lack, over load, over heat, earth and short circuit.
VFD protects in classes and can operate in failure status to achieve continuous operation at the most.
Compatible with an industry standard signal of 010V/420mA
Integrated PID regulator according users requirement.
Exceptional performance/price ratio
2. Parameters
Item | Parameter |
Phase, frequency | Three phase, 50/60Hz |
Allowable frequency fluctuation | ±10% |
Fluctuating voltage | Fluctuating range: ±10% Electric net voltage drops within -35%, VFD derates to operate |
Power factor | >0.95 (20% load) |
Output voltage range | 3kV~11kV |
Output current range | 25A~600A |
Power range | 280kW~8000kW |
Over-load capacity | 120% of rated current for 1min per 10minutes; 150% of rated current for 3s; 200% immediately |
Frequency | 0.5--120Hz |
Efficiency | ≥96% (including transformer) |
Harmonic aberrance | Up to standard of IEEE 519-1992 requirement of power quality standard |
Frequency resolution | 0.01Hz |
Control mode | V/F control or vector control |
Acceleration/deceleration time | 03200s |
I/O port and communication function | Enough I/O port, RS485, Modbus-RTU, Profibus-DP, TCP/IP, DeviceNet and GPRS wireless transmition can be expanded according to users requirement |
Control signal transmittion | By optical fibre |
PID function | Embedded PID regulator, parameter can be set up |
Operation mode | Local/remote, open loop/close loop |
Frequency given | Manual /analogue given |
output | analogue output and digital output |
Work field | Inside room, altitude: below 1000m, no caustic and volatile air, no dust |
Temperature/humidity | Temperature: 0~+40oC; Humidity: below 90%, no condensation |
Storage | -25+55 |
Protection | Over current, short circuit, ground, over voltage, low voltage, over load, over heat, over load of motor, lack-phase, power cell failure, etc. |
Enclose | IP30~IP41 |
Cooling | air cooling/air conditioner/air-water cooling |
| Business Type: | Manufacturer, Distributor/Wholesaler |
| Product/Service (We Sell): | Variable frequency drive,module power source,adjustment of variable frequency drive,maintenance of variable frequency drive,after-sales service of variable frequency drive |
| Brands: | HARSVEST |
| Number of Employees: | 501 - 1000 People |
| Main Markets: | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
| Main Customers: | Power plant, Cement factory, Metullargy, Water pump, City construction, Oil and petrolium industry, etc |
| Export Percentage: | 1% - 10% |
| Factory Size (Sq.meters): | 1,000-3,000 square meters |
| Factory Location: | South Zone of Yangfang Industrial Park, Changping District, Beijing, China |
| QA/QC: | In House |
| Number of R&D Staff: | Above 100 People |
| Number of QC Staff: | 31 - 40 People |
| Management Certification: | ISO 9000/9001/9004/19011: 2000 Others |
| Contract Manufacturing: | OEM Service Offered Design Service Offered Buyer Label Offered |