Home > Products > Security & Protection > Firefighting Supplies > Fire Alarm Control Panel (393)
Language Options more
Check out all Product Listings for fire alarm control panel
Related Searches: fire alarm control panel conventional fire alarm control panel fire alarm with control panel safety products

Addressable Fire Alarm Control Panel OZH4800E

Browse similar products from this supplier
Place of Origin: Guangdong China (Mainland)
Model Number: OZH4800E
Port: Shenzhen
Supply Ability: 500 Piece/Pieces per Month

Supplier Details

Shenzhen Orena Photonic Technology Co., Ltd.

[ Guangdong, China (Mainland) ]
  • Business Type:Manufacturer
  • Product/Services:smoke alarm,smoke detector,fire alarm control panel,heat ...
  • Online Showroom: 49 products
View this Supplier's Website >>
Gold Supplier [ 2nd Year] Verified Supplier
  • Product Details
  • Company Profile
  • Place of Origin: Guangdong China (Mainland)
  • Model Number: OZH4800E

The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.

Key Words: fire alarm control panel, fire alarm, fire alarm panel, FACP, addressable fire alarm control panel, fire panel, fire fighting, fire alarm controller, fire alarm control unit

 

Product Overview

The OZH4800E control panel is an analog addressable fire alarm panel using the latest 32 bit microprocessor technology and containing 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices of any combination (sensors or modules). Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.0 amp power supply, 600 characters LCD display, 29 large easy-to-use tactile touchpad for system operation, programming and maintenance, 12 state indicators and a RS232/RS485 communication port. System operations include silencing alarms and troubles, resetting system and manual starting/stopping field equipment. The system's non-volatile event history buffer stores 9999 events for viewing. The system supports a variety of Orena devices: smoke and heat sensors, manual call points, contact input (monitor) modules, relay output modules, dual input/output modules, and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The basic system can be expanded by adding OZF-LCD remote annunciator, OZH48ZL signalling line circuit expander, and optional mini-printer (for printing system reports). The intelligent panel and detectors know the difference between a fire and a dirty sensor. It lets you tailor sensor sensitivity and gives you immediate, pinpoint accuracy for any condition. The powerful OZH4800E system provides you with revolutionary value and performance in addressable sensing technology, reduces nuisance alarms and makes service calls a rarity.

 

Features:

1) Using advanced industry-standard protocol for fast and stable communication

2) Up to 1536 addressable points, 192 sensors & modules per loop.

3) Uses standard wire, no shielded or twisted pair required on SLC loops.

4) Supports Class B (style 4) and Class A (style 6 or 7) SLC loops

5)  Automatic drift compensation & daily calibration

6) Programmable sensitivity levels per device

7) Large 15-line x 40-character LCD display (600 char.)

8) Built-in help information screens

9) Powerful & versatile Cause & Effect programming (fire protection-related device control)

10) RS-232 /485 communication port

11) Optional mini-printer

 

Specifications

Primary Power Supply: 120V or 220VAC  50/60Hz       

Standby Batteries: DC24V 4AH sealed rechargeable batteries

Power Supply Output: 24VDC @ 5.0 Amps (4 Amps available for system power)

Display: 15 lines x 40 characters LCD (600 characters total)

SLC loops: 2, 4, 6 or 8 (class A, "style 6 or 7" or class B, "style 4")

Devices per loop: 192 sensors & modules

Addresses per panel: 1536 max.

Communication Port: RS232/RS485

Operation Temperature: 10°C~+50°C  Related Humidity: ≤95% (40±2°C)

Dimensions (D * W * H): 110×335×435mm   

Weight: 16Kg.

Orena Sales and Service

Shenzhen Orena Photonic Technology Co., Ltd

Orena Bldg, Zhong'an Industrial Park, Longjing Road, Nanshan District, Shenzhen, 518055, China.

Ph: 86.755.2678.7499      

Fx: 86.755.2678.1400.

Send your message to this supplier

ODH1000 Conventional fire alarm control panel, alarm control panel, fire alarm panel
The professional ODH1000 is a 4/8/16 zone, Class B conventional fire alarm control panel, meet the latest UL864&EN54 standard.
Addressable Fire Alarm Control Panel OZH4800E
The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.
Conventional Fire Alarm Control Panel,alarm control panel,fire alarm panel
Conventional Fire Alarm Control Panel, is also called alarm control panel and fire alarm panel.
Conventional Fire Alarm Control Panel ODH1000
The professional ODH1000 is a 4/8/16 -zone, Class B conventional fire alarm control panel, meet the latest UL864&EN54 standard.
Conventional Fire Alarm Control Panel ODH1000
The professional ODH1000 is a 4/8/16 -zone, Class B conventional fire alarm control panel, meet the latest UL864&EN54 standard.
Addressable Fire Alarm Control Panel,fire alarm control panel,fire alarm panel,panel
Addressable Fire Alarm Control Panel,is also called fire alarm control panel,fire alarm panel and panel.
Addressable Fire Alarm Control Panel,fire alarm control panel,fire alarm panel,panel
Addressable Fire Alarm Control Panel,is also called fire alarm control panel,fire alarm panel and panel.
Addressable Fire Alarm Control Panel OZH4800E
The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.
Addressable Fire Alarm Control Panel OZH4800E
The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.

Let supplier know exactly what you're looking for Post Buying Leads Now!

View More Related Items

Email this page Bookmark this page Print this Page