| Conductor Type: Stranded | Application: Underground | Type: Insulated | Conductor Material: Copper |
Style 10215 Extruded PVDF Copolymer Insulated Flat Wire.
______________________________________________________________________________
Rating 150 deg. C, 600 V.
______________________________________________________________________________
Conductor Bare copper, solid rectangular shaped conductor. Width variable from 400-1500 mils. Thickness variable from 8-35 mils.
______________________________________________________________________________
Insulation PVDF Copolymer 10 mils min avg, 8 mils min at any point. See Facing Page for Compound.
______________________________________________________________________________
*Standard Applinace Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
to UL Dielectric Strength 2000 V for 1 min either
Representative between conductors and metal foil wrapped around the cable or between conductors and two flat steel plates. Insulation shall not crack when cable is flexed flatwise into a U-bend around a 1/2 in dia mandrel.Tensile Strength and Elongation before aging only 3500 psi and 100% min value.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Cold Bend. Insulation shall not crack when
Program cable is flexed into a U-bend around a 1/2 in dia mandrel and taped into place. The cable shall be allowed to cool to -20 deg. C for 1 h.
(4) Age 60 days at 158 deg. C and subject to Dielectric Strength Test described above.
(4) Horizontal Flame Test. One length of cable to be supported flat with flame applied in center of width, and another length of cable held on edge with flame applied on lower edge.
(4) Tensile Strength and Elongation, 3500 psi, and 100% min value, as received only.
______________________________________________________________________________
*Marking General.
______________________________________________________________________________
Use Internal wiring of electronic computers and electric business machines.