Goes to rate of flow 65kA, bigger go on endure press 440V, echo time 25ns, agings designation, hot backup, aging caloric trip,
Arrester | Three phase | EPP100T | EPP80T | EPP65T | EPP60T | EPP50T | EPP40T | EPP30T | EPP20T | |
Single-phase | EPP100S | EPP80S | EPP65S | EPP60S | EPP50S | EPP40S | EPP30S | EPP20S | ||
Rated | 220V | 220V | 220V | 220V | 220V | 220V | 220V | 220V | ||
Flowing rate /circuit | 50kA | 40kA | 32kA | 30kA | 25kA | 20kA | 15kA | 10kA | ||
Imax flowing rate/circuit (will be 8/20 μ s) | 100kA | 80kA | 65kA | 60kA | 50kA | 40kA | 30kA | 20kA | ||
Max Pressure-resistence /circuit Uc | ~440V rms | ~320V rms | ||||||||
Protects voltage Up | 2.5kV | 1.8kV | 1.2kV |
| ||||||
Protects voltage Up (5kA) | 1.5kV | 1.2kV | 0.9kV |
| ||||||
Current Leakage Io | <10 μ A | <3 μ A | ||||||||
Echo time Ta | 25ns | |||||||||
Connection style | Parallel connection | |||||||||
Working temperature | -Will be 40 - +Will be 80 | |||||||||
Installs style | 35mm Normative guide rail install | |||||||||
Function feature | Aging caloric trip and short pass by flow trip (stops caught fire blast) ,indicating lamp can consideration give an alarm, hot backup, far away from letter, agings forecast function | Aging caloric trip and short pass by flow trip (stops caught fire blast) ,indicating lamp can consideration give an alarm, hot backup function |
| |||||||
Protect empty open | 25A Curve C | 16A Curve C | 10A Curve C | |||||||
Max connection size | Connection: 16mm2 Bunched conductors; Conductive earth: 35mm2 Bunched conductors; | |||||||||
SPD boundary dimension | Three phase | 90mm × 144mm × 71mm | 90mm × 72mm × 71mm |
| ||||||
Single-phase | 90mm × 72mm × 71mm | 90mm × 36mm × 71mm |
| |||||||
SPD installs part | Transformer depression mother row or monomer architecture general distribution screen | Monomer architecture general distribution screen | Allots electricity | Equipment side |
| |||||
SPD protects class | I A kind of architecture | II A kind of architecture | III A kind of architecture |
|
| |||||
B Grade (head protection) | C Grade (subordinative protection) | D Grade (last level prevents | ||||||||
| Business Type: | Manufacturer, Distributor/Wholesaler |
| Product/Service (We Sell): | Surge protector,lightning rod,power supply,frequent signal,lighning arrester,decoupler,lightning protective box,Power Strip,Surge protective device |
| Brands: | E-LORD |
| Number of Employees: | 51 - 100 People |
| Main Markets: | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
| Export Percentage: | 21% - 30% |
| Factory Size (Sq.meters): | 3,000-5,000 square meters |
| Factory Location: | Huoshui Communication park 95# BinWen Road high technology development zone Hangzhou city,ZheJiang ,China |
| QA/QC: | In House |
| Number of Production Lines: | Above 10 |
| Number of R&D Staff: | 11 - 20 People |
| Number of QC Staff: | 5 - 10 People |
| Management Certification: | ISO 9000/9001/9004/19011: 2000 Others |
| Contract Manufacturing: | OEM Service Offered Design Service Offered Buyer Label Offered |