features & functions:
| - Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly | |||||||
| - Easy to operate: Combining big screen LCD display with rotary coded switch and membrane keypad makes the operation simple and prompt. | |||||||
| - Working Mode: Infusion | |||||||
| - Memory Function: 1. The parameters are saved in EEPROM.The parameters don't need to be reset when power returns after an interruption. | |||||||
| 2. In flow rate mode, the pump remains running or stop according to the settting parameters when power returns after an Interruption. | |||||||
| - Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked | |||||||
| - Communication Function: Realize computer control through RS485 communication interface | |||||||
| - External Control Function: Input/output control | |||||||
| - Calibration Function: Acquire accurate volume through calibration | |||||||
| - Syringe Protection: Adjust syringe rest to prevent syringe from damaging |
| Specifications: | ||||||
| - Working Mode: Infusion | ||||||
| - Max. No. of Syringes: 4 | ||||||
| - Syringe Size: 10 µl to 10mL | ||||||
| - Linear Force: > 9Kg | ||||||
| - Advance per Micro-step: 0.156 µm | ||||||
| - Infusion Volume per Micro-step: 0.0257 µL(10 mLBD Syringe) | ||||||
| - Max. Step Rate: 13867 (1/16step)/sec | ||||||
| - Min. Step Rate: 16 (1/16 step) /30sec | ||||||
| - Max. Linear Rate: 130 mm/min | ||||||
| - Min. Linear Rate: 5 µm/min | ||||||
| - Flow Rate: 0.831 nL/min- 21.67 ml/min | ||||||
| - Accuracy: < +/- 0.5% error in the condition of > 30% of max. infusion distance | ||||||
| - Setting Mode: Rotary coded switch and membrane keypad | ||||||
| - Display: 128 x 64 graphic LCD | ||||||
| - Power Supply: AC 100 - 240 V | ||||||
| - Operating Condition: Temperature 5°C- 40°C; Relative humidity:< 80% | ||||||
| - Dimensions: 280 x 250 x 140 mm | ||||||
| - Weight: 4.5 kg | ||||||
| Syringe Pump | Hamilton Syringe(mL) | Barrel Inner Diameter(mm) | Ref. Flow Rate(*/min) | Linear Rate(min) | Weight (Kg) |
| LSP04-1A | 50 µL | 1.03 | 0.004 µL - 0.108 mL | 5 µm - 130mm | |
| 1 | 4.61 | 0.083 µL - 2.170 mL | |||
| 2.5 | 7.28 | 0.208 µL - 5.411 mL | 4.5 | ||
| 5 | 10.3 | 0.417 µL - 10.832 mL | |||
| 10 | 14.57 | 0.834 µL - 21.675 mL |
Brief introduction:
This pump is a four channels syringe pump which only has infusion mode. The acceptable syringe specification is from 10 µLto 10 mL.
Suitable for high accuracy and small flow rate liquid transferring.