| Panel sizes: | 48*48, 120*120, 96*96, 80*80,72*72, 160*80, 120*60, 96*48, |
|---|---|
| Brand Name: | MECSTAR/OEM |
| Measuring Range: | three phase I,U,KW,KVAR,KWH,KVARH,HZ,COS etc. |
| Operating Temperature: | -10~55 |
| Accuracy Class: | Display:0.5/0.2class,Frequency meter0.1class,Transmitting:0.5class |
| Dimensions: | 48*48, 120*120, 96*96, 80*80,72*72, 160*80, 120*60, 96*48 |
| Place of Origin: | China (Mainland) |
| Display Type: | Digital Only |
| Model Number: | PD3194I-DK1 |
| Fob Price: | US$10-100Ningbo/Shanghai |
|---|---|
| Port: | Ningbo/Shanghai |
| Payment Terms: | T/T |
| Minimum Order Quantity: | 10 Piece/Pieces |
| Supply Ability: | 1000 Piece/Pieces per Week |
| Package: | Export Package OEM Package |
Technical Data
| Accuracy | Display: 0.50.2 class, Frequency meter 0.1 class, Transmitting: 0.5 class | |
| Display | 4 digit LED display with sign bit | |
| lnput | Nominal input | Current AC1AAC5ADC1ADC5ADC20mA and etcVoltage AC100VAC220VAC380VDC100VDC220VDC380VDC75mV and etc. |
| Overloading | Continuance: 1.2 times, Instantaneous: current 10 times(5s), Voltage 2 times(10s) | |
| Frequency | 50/60Hz±10% | |
| Power supply | Auxiliary power supply | Auxiliary power supply AC/DC80~270VAC220VDC220V and etc. |
| Power consumption | 4VA | |
| Isolation withstand voltage | Power supply and inputTransmitting outputCommunication interface AC2kV, InputTransmitting outputCommunication interface between each other AC1kV | |
| Insulation resistance | ≥100MΩ | |
| Mean time between failures | ≥50000h | |
| Operation condition | Ambient temperature: -1055, Relative humidity ≤93%, No corrosive gas, Height above sea level≤2500m | |
| Output | Analog value | When DC4~20mA current output, Load510Ω, When DC0~5V voltage output, Load100kΩ |
| Digital value | RS-485 interface, MODBUS-RTU protocol, Baud rate default 9600(optional 48009600)bps | |
| 120x120 Programmable Digital Meter Type Selection Table |
| Model | Type | Measurement | Optional |
| PA3194I-2K1/* | AC Ammeter | Single phase IL | Note: optional function with "*" 1. RS485 communication function(C) 2. One loop 4-20mA or 0-20mA analog value(B) 3. Relay alarm (J) |
| PA3195I-2K1/* | DC Ammeter | Single phase IL | |
| PA3194I-2K4/* | AC Ammeter | Three phase IaIbIc | |
| PZ3194U-2K1/* | AC Voltmeter | Single phase ULN | |
| PZ3195U-2K1/* | DC Voltmeter | Single phase ULN | |
| PZ3194U-2K4/* | AC Voltmeter | Three phase U1U2U3 | |
| PD3194F-2K1/* | Frequency Meter | Hz | |
| PD3194H-2K1/* | Power Factor Meter | COSφ | |
| PS3194P-2K1/* | Single Power Meter | Single phase kw | |
| PS3194P4(P3)-2K1/* | Three Phase Active Power Meter | Three phase kw | |
| PS3194Q4(Q3)-2K1/* | Three Phase Reactive Power Meter | Three phase kvar | |
| PD3194UI-2K4 | AC Voltage & Current Combined Meter | Three phase IaIbIc; Three phase U1U2U3 | |
| PD3194PQ-2K4 | Three Phase Active & Reactive Power Combined Meter | kWkVarCOSφHz Three phase UaUbUcIaIbIckWkVarCOSφHz |
| 96x96 Programmable Digital Meter Type Selection Table |
| Model | Type | Measurement | Optional |
| PA3194I-9K1/* | AC Ammeter | Single phase IL | Note: optional function with "*" 1. RS485 communication function(C) 2. One loop 4-20mA or 0-20mA analog value(B) 3. Relay alarm (J) |
| PA3195I-9K1/* | DC Ammeter | Single phase IL | |
| PA3194I-9K4/* | AC Ammeter | Three phase IaIbIc | |
| PZ3194U-9K1/* | AC Voltmeter | Single phase ULN | |
| PZ3195U-9K1/* | DC Voltmeter | Single phase ULN | |
| PZ3194U-9K4/* | AC Voltmeter | Three phase U1U2U3 | |
| PD3194F-9K1/* | Frequency Meter | Hz | |
| PD3194H-9K1/* | Power Factor Meter | COSφ | |
| PS3194P-9K1/* | Single Power Meter | Single phase kw | |
| PS3194P4(P3)-2K1/* | Three-phase Active Power Meter | Three phase kw | |
| PS3194Q4(Q3)-2K1/* | Three-phase Reactive Power Meter | Three phase kvar | |
| PD3194UI-9K4 | AC Current & Voltage Combined Meter | Three phase IaIbIc; 3 phase U1U2U3 | |
| PD3194PQ-9K4 | Three Phase Active & Reactive Power Combined Meter | Three phase UaUbUcIaIbIckWkVarCOSφHz |
| 96x48 Programmable Digital Meter Type Selection Table |
| Model | Type | Measurement | Optional |
| PA3194I-5K1* | AC Ammeter | Single phase IL | Note: optional function with "*" 1. RS485 communication function(C) 2. One loop 4-20mA or 0-20mA analog value(B) 3. Relay alarm (J) |
| PA3195I-5K1/* | DC Ammeter | Single phase IL | |
| PZ3194U-5K1/* | AC Ammeter | Single phase ULN | |
| PZ3195U-5K1/* | DC Ammeter | Single phase ULN | |
| PD3194F-5K1/* | Frequency Meter | Hz | |
| PD3194H-5K1/* | Power Factor Meter | COSφ | |
| PS3194P-5K1/* | Single Phase Power Meter | Single phase kw |