| COLOR: | GRAY |
|---|---|
| Brand Name: | HuaRu Technology |
| Type: | Vacuum |
| Place of Origin: | Zhejiang China |
| Model Number: | ZW32-12/630 |
| Poles Number: | 3 |
| Port: | ShangHai |
|---|---|
| Payment Terms: | L/C,T/T |
| Minimum Order Quantity: | 1 Set/Sets |
| Supply Ability: | 10000 Set/Sets per Year |
| Package: | Packaging requirements are in accordance with international standards. Ensure the products safety on the road or marine transportation, and meet the requirements for many times lifting. Specific form can be decided according to the products, and, the product can be transported directly into the container. |
| Delivery Time: | 4 months after the technical parameters are confirmed |
ZW32-12 Series Outdoor Pole HV Vacuum Circuit Breaker:
General:
ZW32-12 Type Outdoor Pole HV Vacuum Circuit Breaker is an outdoor HV breaker with rated voltage of 12KV ,three-phase AC 50 HZ .it can be used in opening and closing loaded current and short-circuit current in T&D system, it is suitable in power station industrial enterprisees and mines,10KV fitting power for protection and controlling ,as well as in places for frequest operations.The product adopt with the latest international design idea and the technology of sealing silicon latex with epoxy and exectitude process art,the technology index fit IEC56,GB1984 AC HV Breaker and community technology condition of GB/T11022 HV switchgear and equipment controlling standard.The technology level is advanced in home with the advantages of exempts the maintenance ,small,light weight,intelligentize,high reliable and beautiful externality.
Number | Project | Unit | Value | |
1 | Rated Voltage | kV | 12 | |
2 | Rated Frequency | Hz | 50 | |
3 | Rated Current | A | 630 | |
4 | Rated short-circuit breaking current | kA | 20 | |
5 | Rated peak withstand current | kA | 50 | |
6 | Rated short-time withstand current /duration time timentimeshort-time | kA/S | 20/4 | |
7 | Rated short circuit making current(peak value) | kA | 50 | |
8 | Rated operating cycle |
| on-0.3 S-on-off-180S-on-off | |
9 | Mechanical life | Time | 2000 | |
10 | Rated current breaking number of time | Time | 10000 | |
11 | Times of rated short-circuit breaking current | Time | 30 | |
12 | Work withstand voltage (1min):to phase/earth | Dry | kV | 42 |
Wet | kV | 34 | ||
13 | Lighting impact withstand current(peak value):tophase/earth | kV | 75 | |
14 | Secondary circuit 1 min power f requency withstand voltage | kV | 2 | |