The raiway signalling cables are designed to give good protection to the core against inductive interference (RF
PE Insulated Air Core/Jelly Filled Star Quad Railway Signalling Cables (RF 0.1)
Application
The cables are designed to give good protection to the core against inductive interference (RF=0.1).The cables are used for outdoor signaling equipment.
Standards
RENFE E.T. 03.365.051.6
Construction
Conductors
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228
Insulation
Solid polyethylene as per ASTM D 1248/IEC 60708
Cabling Element
Four insulated conductors are twisted together to form a quad
Cable Core Assembly
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
Electrostatic Screen
One layer of copper wires 0.12mm is applied helically
Bedding
PE or LSZH
Electrostatic Armour
Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one
Sheath
PE/PVC or LSZH
Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
Electrical & Mechanical Properties
Nominal Conductor Diameter | mm | 0.9 | 1.4 |
Conductor Size | mm2 | 0.636 | 1.539 |
Maximum Conductor Resistance 20°C | ohm/km | 28 | 12.1 |
Minimum Insulation Resistance 500V DC | Mohm.km | 35000 | 5000 |
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km |
| 0.1 | 0.1 |
| Induced Voltage Em 500V/Km | 0.16 | 0.16 | |
Maximum Resistance Unbalance | % | 2.5 | 2.5 |
Maximum Mutual Capacitance 0.8KHz | nF/km | 45 | 50 |
Maximum Capacitance Unbalance 1KHz pair-to-pair | pF/500m | 250 | 250 |
Maximum Capacitance Unbalance 1KHz pair-to-ground | pF/500m | 1200 | 1200 |
Maximum Average Attenuation 1KHz | dB/km | 0.7 | 0.46 |
Maximum Average Attenuation 10KHz | dB/km | 1.6 | 0.85 |
Maximum Average Attenuation 20KHz | dB/km | 2.1 | 1.3 |
Dielectric Strength Conductor to Conductor 3secs | V DC | 3000 | 3000 |
| Conductor to Screen 3secs | V DC | 3500 | 3500 |
Minimum Insulation Thickness | mm | 0.45 | 0.65 |
Maximum Insulated Conductor Diameter | mm | 1.8 | 2.7 |
| Business Type: | Manufacturer |
| Product/Service (We Sell): | Coaxial cables,control cables,fiber optic cables,flexible cables,instrumentation cables,railway cables,rolling stock cables,telephone cables,bus cables,high temperature cables,patch cords,fiber patch cords |
| Number of Employees: | 101 - 500 People |
| Main Markets: | North America South America Eastern Europe Mid East |
| Contract Manufacturing: | OEM Service Offered |