Home > Products > Telecommunications > Communication Equipment > Communication Cables (294839)
Language Options more
Check out all Product Listings for Railway Cables
Related Searches: Railway Cables railway signal cables power cable hdmi cable

Railway Cables

Brand Name: ATL
Place of Origin: Shandong China (Mainland)
Click to send an inquiry

Supplier Details

Jinan ATL Technology Limited

[ Shandong, China (Mainland) ]
Gold Supplier [ 1st Year] Verified Supplier
  • Business Type:Manufacturer
  • Product/Services:Coaxial cables,control cables,fiber optic cables,flexible ...
  • Online Showroom: 174 products
similar products from this supplier
View this Supplier's Website >>
  • Product Details
  • Company Profile
  • Brand Name: ATL
  • Place of Origin: Shandong China (Mainland)

The raiway signalling cables are designed to give good protection to the core against inductive interference (RF

PE Insulated Air Core/Jelly Filled Star Quad Railway Signalling Cables (RF 0.1)

Application

The cables are designed to give good protection to the core against inductive interference (RF=0.1).The cables are used for outdoor signaling equipment.

Standards

RENFE E.T. 03.365.051.6

Construction

Conductors
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228

Insulation
Solid polyethylene as per ASTM D 1248/IEC 60708

Cabling Element
Four insulated conductors are twisted together to form a quad

Cable Core Assembly
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders

Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Electrostatic Screen
One layer of copper wires 0.12mm is applied helically

Bedding
PE or LSZH

Electrostatic Armour
Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one

Sheath
PE/PVC or LSZH

Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical & Mechanical Properties

Nominal Conductor Diameter

mm

0.9

1.4

Conductor Size

         mm2

0.636

1.539

Maximum Conductor Resistance 20°C

     ohm/km

28

12.1

Minimum Insulation Resistance 500V DC

   Mohm.km

35000

5000

Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km

 

0.1

0.1

                                     Induced Voltage Em 500V/Km      0.16     0.16

Maximum Resistance Unbalance

%

2.5

2.5

Maximum Mutual Capacitance 0.8KHz

      nF/km

45

50

Maximum Capacitance Unbalance 1KHz pair-to-pair

    pF/500m

250

250

Maximum Capacitance Unbalance 1KHz pair-to-ground

    pF/500m

1200

1200

Maximum Average Attenuation 1KHz

     dB/km

0.7

0.46

Maximum Average Attenuation 10KHz

     dB/km

1.6

0.85

Maximum Average Attenuation 20KHz

     dB/km

2.1

1.3

Dielectric Strength Conductor to Conductor 3secs

      V DC

3000

3000

                           Conductor to Screen 3secs      V DC     3500     3500

Minimum Insulation Thickness

mm

0.45

0.65

Maximum Insulated Conductor Diameter

mm

1.8

2.7

Send your message to this supplier

Railway Cables
The raiway signalling cables are designed to give good protection to the core against inductive interference (RF
Telephone Cables
The railway signalling cables are designed to give good protection to the cable cores against inductive interference (RF=0.3).
Telephone Cables
Special Telephone Cables The railway signalling cables are designed to give good protection to the core against inductive inter

Let supplier know exactly what you're looking for Post Buying Leads Now!

View More Related Items

Email this page Bookmark this page Print this Page