VERTICAL | | Channels | 2 | | Bandwidth | DC~150MHz(-3dB) | | Rise Time | <2.3ns Approx. | | Sensitivity | 2mV/div ~ 10V/div (1-2-5 increments) | Accuracy
| ±(3% x |Readout| + 0.1 div + 1mV) | | Input Coupling | AC, DC & Ground | Input Impedance
| 1MΩ±2%, ~15pF | | Polarity | Normal & Invert | Maximum Input
| 300V (DC+AC peak), CATII | | Waveform Signal Process | + , - , x, FFT, FFTrms | Offset Range
| 2mV/div ~ 50mV/div : ±0.4V 10mV/div ~ 500mV/div : ±4V 1V/div ~ 10V/div : ±40V | | Bandwidth Limit | 20MHz (-3dB) | TRIGGER | | Sources | CH1 , CH2 , Line , EXT | Modes
| Auto, Normal, Single, TV, Edge, Pulse Width | | Coupling | AC , DC , LF rej. , HF rej. , Noise rej. | | Sensitivity | DC ~ 25MHz: Approx. 0.5div or 5mV; 25MHz ~ 150MHz: Approx. 1.5div or 15mV | EXT TRIGGER | | Range | ±15V | | Sensitivity | DC ~ 25MHz : ~ 50mV ; 25M ~ 150MHz : ~100mV | | Input Impedance | 1MΩ±2% , ~ 15pF | | Maximum Input | 300V (DC AC peak) , CATII | HORIZONTAL | | Range | 1ns/div ~ 50s/div (1-2-5 increments); ROLL : 250ms/div ~ 50s/div | | Modes | Main, Window, Window Zoom, Roll, X-Y | | Accuracy | ±0.01% | | Pre-Trigger | 10 div maximum | | Post-Trigger | 1000 div | X-Y MODE | | X-Axis Input | Channel 1 | Y-Axis Input
| Channel 2 | | Phase Shift | ±3°at 100kHz | SIGNAL ACQUISITION
| | Real-Time Sample Rate | 1GSa/s maximum | | Equivalent Sample Rate | 25GSa/s maximum | | Vertical Resolution | 8 Bits | | 2 Mega Points maximum | Acquisition Mode
| Normal, Peak Detect, Average | Peak Detection
| 10ns (500ns/div ~ 10s/div) | Average < | 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 | CURSORS AND MEASUREMENT | | Voltage Measurement | Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot | | Time Measurement | Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle | | Cursors Measurement | Voltage difference between cursors (V) Time difference between cursors (T) | Auto Counter
| Resolution : 6 digits Accuracy: 2% Signal Source: All available trigger source except the Video trigger mode | | ADJUSTABLE PROBE COMPENSATION SIGNAL | | Frequency Range | 1kHz ~ 100kHz, 1kHz/STEP | | Duty Cycle Range | 5% ~ 95%, 5%/STEP | | CONTROL PANEL FUNCTION | | Autoset | Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically | | Save Setup | Up to 15 sets of measurement conditions | | Save Waveform | 15 sets of waveform | | DISPLAY | | TFT LCD Type | 5.6 inch | | Display Resolution | 234(Vertically) x 320(Horizontally) Dots | | Display Graticule | 8 x 10 divisions | | Display Brightness | Adjustable | | INTERFACE | | USB Slave Connector | USB1.1 & 2.0 full speed compatible (printers and flash disk not supported) | | SD Card Slot | Image (BMP), waveform data (CSV), and setup (SET) | | POWER SOURCE | | Line Voltage Range | AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection | | MISCELLANEOUS | | Multi-Language Menu | Available | | Onscreen Help | Available | | ACCESSORIES | | User manual x 1 Power Cord x 1 GTP-150A-2 Probe(10:1/1:1) x 2 | | DIMENSIONS &WEIGHT | | | 310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg |
|