It is mainly used to wireless monitor people's ECG signal. It contains ECG Collector, Smartphone and ECG Monitor Service Center
Wireless ECG Monitoring system features
The system amalgamates multiple advanced technologies of medicine and IT field and realizes the cardiogram monitoring of the patient Anytime Anywhere in the global range depending on the network resource around the world. The doctors do remote monitoring, analysis and conduction to the cardiogram signals, and thus reach the objectives of remote medical care, conducting illness at home and centralized administration of the patients, and annotate the new concept of network and digital monitoring.
The patients can timely get the diagnosis data or doctor's advice from the monitoring doctors and conveniently and rapidly enjoy cardiogram monitoring anytime and anywhere through the system; to abrupt malignant cardiovascular disease, the important relatives and monitoring doctors of the patients can be informed at the first time, and thus make the patients rapidly get effective treatment or saving in shortest time, greatly reducing the sudden death probability of the patients with cardiovascular disease.
Basic Parameters
1. Cardiogram collector
Cardiogram record channel: 2channels (lead).
Storage medium SD card (512MB/1GB)
Power supplyLi-ion chargeable battery,withstand capacitance is680mAH, 3.7V
A/D conversion accuracy 12 Digits
Sampling Rate (180-512) times/S
Function: collect and transform cardiogram signals.
2. Average working time without hitches of monitoring system ≥1000h.
Technical Parameters
1. Input dynamic range should no narrower than 5mVp-p.
2. Accuracy of standard signals should be 10mm/mV,deviation should be ±5%.
3. Anti-polarization voltage: adding DC polarization voltage within ±300mV, sensibility changing range should be ±5%.
4. Internal noise should be in regulated frequency range, no more than 50μVp-p.
5. Baseline stabilitya) baseline float amount of time float should no bigger than 5mmAverage temperature float should no more than 0.5mm/
6. Sensibility deviation5mm/mV, 10mm/mV, 20mm/mV, transforming deviation range for three grades should be ±5%.
7. Input impedance: input impedance of positive electrode in each channel to negative electrode should no less than 2.5MΩ.
8. Input loop currentInput loop current of each channel should be no more than 0.1μA.
9. CMRRCMRR of cardiogram collector to power frequency should no less than 60dB.
10. Amplitude frequency featureshould meet requirements of 0.05 Hz 60 Hz .
11. Time constants: should be no less than 3.2s| Business Type: | Manufacturer |
| Product/Service (We Sell): | Lithotripter,orthopedic equipment,wireless ecg monitor |
| Brands: | newelement |
| Number of Employees: | Above 1000 People |
| Main Markets: | North America South America Eastern Europe Southeast Asia Africa Mid East Eastern Asia Western Europe |
| Main Customers: | ENGEMED INDUSTRIA E COMERCIO LTDA |
| Total Annual Sales Volume: | Below US$1 Million |
| Export Percentage: | 21% - 30% |
| Total Annual Purchase Volume: | US$1 Million - US$2.5 Million |
| Factory Size (Sq.meters): | 3,000-5,000 square meters |
| Factory Location: | 4&5/F, Building 422, Bagua 4th Road, Futian District, Shenzhen, China |
| QA/QC: | In House |
| Number of Production Lines: | 3 |
| Number of R&D Staff: | 71 - 80 People |
| Number of QC Staff: | 5 - 10 People |
| Management Certification: | Others |
| Contract Manufacturing: | OEM Service Offered Design Service Offered Buyer Label Offered |