Home > Products > Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Power Cables (30794)
Language Options more
Check out all Product Listings for ACSR ASTM
Related Searches: ACSR ASTM astm a36 plate astm astm a53

ACSR conductor ASTMB232 standard

overhead: power station
ISO: ISO9001&ISO14001
standard: IEC61089, ASTM B232, BS215, DIN48204, CSA C49
Brand Name: HNTDDL
Conductor Material: aluminum and steel
Application: Power Station
Type: High Voltage
Place of Origin: Henan China (Mainland)
Port: QINGDAO SHANGHAI NINGBO
Payment Terms: L/C,T/T
Minimum Order Quantity: 2 Kilometer
Supply Ability: 5000 Kilometer per Month
Package: Wooden drum, Steel wooden drum, Steel drum or your requirement.
Delivery Time: 20 working days
Click to send an inquiry

Supplier Details

Henan Tong-Da Cable Co., Ltd.

[ Henan, China (Mainland) ]
Gold Supplier [ 2nd Year] Verified Supplier
  • Business Type:Manufacturer
  • Product/Services:ACSR,AACSR,AAC,AAAC,conductor,ACSR/AW,ACAR,wire,electric wire,pvc ...
  • Online Showroom: 766 products
similar products from this supplier
View this Supplier's Website >>
  • Product Details
  • Company Profile
  • overhead: power station
  • ISO: ISO9001&ISO14001
  • standard: IEC61089, ASTM B232, BS215, DIN48204,...
  • Brand Name: HNTDDL
  • Conductor Material: aluminum and steel
  • Application: Power Station
  • Type: High Voltage
  • Place of Origin: Henan China (Mainland)

We have obtained certificates of ISO9001, ISO14001.
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182

Applications
 
AAC,AAAC,ACSR,AACSR&ACAR conductor widely used in power transmission lines 
with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and 

maintenance, low cost for the line, large transmission capacity and are also suitable for laying 

across rivers and valleys where special geographical teatures exist.


1. Specification:


(1) all aluminium conductor (AAC)

(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)

(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)

(7)aluminimum conductor aluminimum alloy reinforced(ACAR)


2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.

1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.


2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.


3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228


(AAAC) Conductor as per ASTM-B-399-1992


(AAAC) Conductor as per BS-3242-1970


(AAAC) Conductor IS: 398-IV-1994


(ACSR) as per ASTM-B-233-1992


(AAC) as per BS-215-1-1970


(AAC) as per IS-398-1: 1976


(AAC) as per ASTM-B-231-1990


(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992


(ACSR) BS-215-II-1970


(AACSR) as per IEC-1089-1191


AAC(All aluminum conductor) are suited for overhead power line.


We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.


ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.


Applications:


Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.


Construction:


Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.


Specifications:


ACSR bare conductor meets or exceeds the following ASTM specifications:


B-230 Aluminum Wire, 1350-H19 for Electrical Purposes


B-231 Aluminum Conductors, Concentric-Lay-Stranded


B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)


B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)


B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)


Notes:


Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.


Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Send your message to this supplier

ACSR ASTM B232 conductor
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 1 Ton
ACSR ASTM standard conductor
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 1 Ton
ACSR ASTM B232 American standard Conductor
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 2 Kilometer
ACSR cable ASTM B232
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 2 Kilometer
ACSR conductor ASTMB232 standard
We have obtained certificates of ISO9001, ISO14001. IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182
Min. Order: 2 Kilometer
with grease ACSR
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 1 Ton
with grease ACSR
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 1 Ton
ACSR with grease conductor
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 1 Ton
with grease ACSR conductor
IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 Used for overhead electrical distribution and transmission lines.
Min. Order: 1 Ton

Let supplier know exactly what you're looking for Post Buying Leads Now!
Email this page Bookmark this page Print this Page