RDX6-63 CIRCUIT BREAKER

Place of origin:  China
Model No:  RDX6-63
Brand Name:  People
Click to send an inquiry

Features Specifications: RDX6-63 CIRCUIT BREAKER

Type: Mini Certificate: CE

TECHNICAL SPECIFICATIONS:

 

Pole: one pole, two poles, three poles, four poles
Rated voltage: 110/230/400V
Rated frequency: 50/60Hz
Rated short-circuit lnterrupting capacity: 10KA
Electric endurance: In the case of Un, In and COS=0.90 and the 63A and below, it is eight-
     thousand times of cycles; in the case of 80A to 100A, it is 1500 times of cycles (Each times of   cycle includes one time of making operation and one minute of breaking operation).
Voltage endurance: Power frequency voltage endurance 2000V (1 min), pulse voltage endurance
      (1.2/50 μs).
Impact resistance performance: Withstand the impact of 10ms and 20g at least 18 times, and
     withstand the impact of 5ms and 40g at least 18 times, and withstand the shake of 10~55Hz at least half an hour.
Storage temperature: According to chapter one section two IEC60898 (for a duration of 96 hours)
     -55~+55
Working environment temperature:-5~+45
Wiring capabillty: 63A and below: 25mm2 and below for soft wire and 35mm2 and below for
     hard wire.
80A~100A: 35mm2 and below for soft wire and 50mm2 and below for hard wire.
DC application: 1A~63A: rated breaking breaking capability: 6KA; maximum voltage: single
     pole 60V; dual-pole series 110V; 80A~125A; rated short-circuit breaking capability: 10KA;
     maximum.
Voltage: dual-pole series 125V; four-pole series 250V; transient tripping current is high about
      40% compared with the case of 50/60Hz.

ACCESSORIES:

 

Shunt trip
Auxilliary contact
Contact with alarm indication
Under voltage trip

TECHNICAL SPECIFICATIONS:

 

According to standard: 63A less than: IEC60898 GB10963 80~100A: IEC947-2 GB14048.2
Modular design: width of 18mm or 27mm (125A case grade) at different environment condition. 
Selection of rated current according to the temperature adjustment curve.Free tripping mechanism: In the case of short circuit and overload, the circuit breaker would automatically trip. Before the failure eliminates, the circuit would refuse to switch againg even the hand handle at the close position to avoid the intentional switching of the failure circuit mistakenly.
Transient tripping performance: B-type performance: 3~5In;
                                                         C-type performance: 5~10In
                                                         D-type performance:10~20In