Principle and Structure for Door Lock System :
The system consist of the locks which all be connected to the controllers (by wireless ) , so that the PC can monitor and record all the operations on the lock in real time through controllers :
Function One of Electronic Door Lock through Wire-network :
Five Grade Management : General Control ,Building Control,Floor Control, Group Control, Room Control .
Password Control( there is two types password ,they work together to ensure the whole hotel door locks safety ) :
One is System password : to distinguish different hotel system , avoiding different hotel keycard to open doors mutually
Another is operators password (different operator have different password )
District Control : different kind and grade card can open doors of different districts
Time Control : to control the time of keycard operation through the clock that is set inside the lock
Record Function : to record all the operation of issuing card and track all opening history
Lost Report : to cancel the opening qualification of some lost card or other designated cards .
Monitor Function : to collect information of the lock status in real time .
Function Two of Electronic Door Lock through Wireless-network (Special characteristic ):
Monitor the lock status by computer:
you can monitor all the lock status(such as open, close, not close alarm, deadbolt,etc.)by computer.
All the informations(such as open, close, not close alarm, deadbolt, etc.) will indicate on the computer. Especially, when lock status is changed, its icon also will be changed on the computer.
Constitution of the lock system :
1. System consist of : Electronic door lock, smart card ,PC, managing software, smart Temic5557 card issuer , General Controller
Extension function : to attain one-card-pass ,this lock system can be added on other parts as terminal settings according to the hotels need, such as energy saving switch ,safe, attendance recorder, parking, access control system etc .
Technical index of Wireless lock system :
1.Power Supply: DC6V, use of 4 pieces of No.5 (or No.7) AA batteries, with lack of voltage indications.
2.Static Power Supply of lock: <40u A>
3.Dynamic Power Supply of lock: About 100mA
4.Lifetime of battery: For the allowed door open times, it normally can exceed 16,000times.
5. T5557 card Inductive Distance: 3-7cm
6.Open door Record inside the lock: collected in the computer without limitation
7.Setting Requirement:
Working temperature -20'C~70'C, humidity:98%max.
8.Anti-static Electricity: Totally closing status, the problem of static electricity is resolved.
9. Receiving Level distance from lock to Controller: 150meters per Controller.
Receiving Vertical distance from lock to Controller: 30meters per Controller.
Note: You can add the quantity of the controllers to expand Level distance and Vertical distance.
10. Dynamic Power Supply of Controller: Max. 11mA.