80kW GHP natural gas heat pump air conditioner driven by gas engine

FOB Reference Price:Get Latest Price
$20,000.00 - $29,000.00 / Sets | 1 Set/Sets (Min. Order)
Model Number:
SA80NHCS-1/1A
Power:
380V
Lead Time:
Quantity(Sets) 1 - 5 >5
Est. Time(days) 45 Negotiable
Customization:
Customized logo (Min. Order: 1 Sets)
Customized packaging (Min. Order: 1 Sets)

More

Graphic customization (Min. Order: 1 Sets)
Configuration (Min. Order: 1 Sets) Less
Report Suspicious Activity
Overview
Quick Details
Type:
Cabinet Air Conditioner
Dimension(L*W*H):
2288*1205*2407 mm
Mounting:
Ceiling Mount
Warranty:
5000 hours or one year
After-sales Service Provided:
Video technical support, Field installation, commissioning and training, Online support
Applicable Industries:
Hotels, Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Home Use, Food Shop, Energy & Mining, Hospital
Condition:
New
Place of Origin:
Sichuan, China
Brand Name:
SMART ACTION
Operating Voltage:
380/400 VAC
Nominal refrigerating capacity:
80kW
Nominal heating capacity:
150kW
Heat recovery in refrigerating condition:
60kW
Power supply:
380V-3P/N
Frequency:
50Hz
Refrigerant / filling amount:
R407C / 25kg
Compressor type:
Piston
Weight:
1000kg
Max water resistance:
100kPa
Product name:
80kW GHP natural gas heat pump air conditioner driven by gas engine
Supply Ability
Supply Ability:
500 Set/Sets per Year 80kW GHP natural gas heat pump air conditioner driven by gas eng
Packaging & Delivery
Packaging Details
1. Wooden box
2. Steel pallet
3. As the requirement of the customers.
Port
Chengdu, Shanghai
Picture Example:
package-img
Lead Time :
Quantity(Sets) 1 - 5 >5
Est. Time(days) 45 To be negotiated
Video Description

80kW GHP natural gas heat pump air conditioner driven by gas engine

 

 

    

           40kW natural gas GHP                           20kW biogas CHP                            200kW natural gas GHP     

          8kW biogas generator                   250kW natural gas generator                 65kW natural gas GHP

 

 

80kW Natural Gas Heat Pump Air-conditioner

 

What is GHP?

    GHP (Gas Heat Pump Air Conditioning), operating on clean burning gaseours fuel (natural gas), provides both cooling and heating by circulating refrigerant with a compressor driven by a gas engine.

 

    The difference between GHP and air source heat pupm air conditioning is: the former is driven by a gas engine which uses natural gas as the fuel while the latter is driven by a electric motor which uses the electricity as the engergy.

 

This gas engine driven compressor has 2 advantages:

  • Waste heat from the gas engine available
  • No need for motor power consumption thanks to gas engine

 

Cooling (and hot water) in summer / Heating in winter in One System

    In summer, the GHP can use the exhaust heat and the gas engine to produce hot water with big amount and high temperature. The highest temperature can reach to 75℃. By adding storage tank for the hot water, the gas water heater can be almostly stopped to use and the energe consumption of the hot water system can be reduced a lot.

 

 

 

ModelSA40NHCS-1/1ASA65NHCS-1/1ASA80NHCS-1/1A
PerformanceNominal refrigerating capacity1kW406580
Heat recovery in refrigerating condition2kW304860
Heating capacityNominal3kW75121150
Ultralow temperature4kW45.575.591
Gas consumption6 (LHV) Nominal refrigerating  kW47.575.895
Nominal heating  kW47.575.895
Electrical characteristics   RefrigeratingOperating current  A 2.283.80 4.37 
Power consumption kW 1.22.3 
 HeatingOperating current   A2.283.80 4.37 
Power consumptionkW1.222.3
Starting currentA30
Water flowRefrigeratingm3/h6.8811.1813.76
Heatingm3/h12.920.8125.80
Domestic hot waterm3/h5.168.2610.32
CompressorType Piston
Displacementcm3/rev650776976
Lubricant grade Fuchs Reniso Triton SE 55/Fuchs SEZ 32/68/80/Esso/Mobil EAL Arctic 46
Refrigerant oil filling amountL2.02.5
Gas engineEngine oil grade 5W-40
Engine oil filling amountL3045
Startup mode Electric start
Engine coolantFilling amountL3045
Concentration / Freezing temperature 50V/V% ~ -35℃
Refrigerant filling amount (R407)kg152025
DimensionsLengthmm13882288
Widthmm12051205
Heightmm22482407
Weightkg6009001000
Maximum water resistancekPa6080100
Pipe interfaceWater pipe of air conditioning DN40 FlangeDN50 Flange
Hot water pipe G1'' G1-1/2'' 
Gas pipemmG1/2'' G3/4'' 
NoisedB (A)606365
FanAir supply form Axial Fan * 1Axial Fan * 2
Rated air volumem3/h135002200027000

Note:

1. Nominal refrigerating capacity: outdoor temperature is 35°C; outlet water temperarure is 70°C.

2. Heat recovery in refrigerating condition: outlet water temperature is 45°C (can be raised to 70°C).

3. Heating capacity (nominal): outdoor temperature is 7/6°C; outlet water is 45°C (can be raised to 55°C).

4. Ultralow temperature (nominal): outdoor temperature is -12/-14°C; outlet water is 41°C (can be raised to 45°C).

5. Fuel type is natural gas. Gas intake pressure is 2.5 - 3.5kPa.

6. Actual gas consumption (Nm³/h) = Gas consumption (kW) * 3.6/35.4 (MJ/Nm³). (When heat value is 35.4MJ/Nm³)