BOQU 4 20ma ,modbus digital output electromagnetic water flow meter

FOB Reference Price:Get Latest Price
$150.00 - $450.00 / Pieces | 1 Piece/Pieces (Min. Order)
Material:
PTFE lining,carbon ,SS304 housing
Accuracy:
0.5%
Size:
DN6~DN2600
Lead Time:
Quantity(Pieces) 1 - 1 2 - 200 >200
Est. Time(days) 7 15 Negotiable
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Shanghai, China (Mainland)
Brand Name:
water hose flow meter
Model Number:
michael(@)shboqu.com
Name:
water hose flow meter
Contact:
michael(@)shboqu.com
Mob:
86-150 0008 7545
Connection size:
DN6~DN2000
Accuracy:
0.5%
Output:
pulse,4-20mA
Communication:
RS485,RS232,wirless,GPRS function
Power Supply:
AC220V DC24V,battery
Application:
water,waste water,slurry,pulp,etc
Certificate:
ISO,CE,SGS,Explosion-proof
Supply Ability
Supply Ability:
8000 Piece/Pieces per Month electromagnetic flow meter
Packaging & Delivery
Packaging Details
carton box ,plywood box and michael(@)shboqu.com and mob/whatsapp:86-150 0008 7545
Port
Shanghai
Lead Time :
Quantity(Pieces) 1 - 1 2 - 200 >200
Est. Time(days) 7 15 To be negotiated

BOQU 4 20ma ,modbus digital output electromagnetic water flow meter

Premium Water Magnetic Electromagnetic Flow Meter

Magnetic flow meters are often selected because they are obstructionless, cost-effective for aggressive chemicals,slurries,wastewater applications or any dirty liquid which is conductive or water based and provide highly accurate volumetric flow measurement. A range of liner materials, electrode options and line sizes accommodate a wide variety of process applications. Additionally, magnetic meters are beneficial in that they can measure fluids bi-directionally, are effective for both very low and high volume flow rates and are immune to changes in process variables. Magnetic flow meters are also ideal for applications where low-pressure drop and low maintenance are required.

Product Description

Features of water hose flow meter

1) Measurement is not affected by the variation of flow density, viscosity, temperature, pressure.
2) High accuracy measurement is guaranteed according to the linear measurement principle.
3) No moving in the pipe, no pressure-loss and lower requirement for straight pipeline.
4) DN 6 to DN2000 covers a wide range of pipe size.

5) A variety of liners and electrodes are available to satisfy different flow characteristic.
6) Measurement stability and reducing power consumption.
7) Implementing 16 bits MCU, providing high integration and accuracy;

8) Full-digital processing, high noise resistance and reliable measurement;

9) Flow measurement range up to 1500:1.
10) High definition LCD display with backlight.
11) RS485 or RS232 and Wireless Function
12) SMD component and surface mount technology (SMT) are implemented to improve the reliability. 

Main controller parameters of water hose flow meter

Production NameMagnetic Flow Meter
Mediuimwater,wastewater,slurry,sea water, mud and other conductivity liquids
DiameterDN10~DN2000mm
Accuracy+/-0.5%
Temperature<80℃(rubber); <180℃(PTFE)
Pressure4.0Mpa(DN10~80);1.6Mpa(DN100~150);1.0Mpa(DN200~1000);0.6Mpa(DN1200~2000)
Flow speed0.3~10m/s
ElectrodeSS316L(standard);Titanium;Tantalum;Hastelloy,platinum
LiningPTFE;Rubber;polyurethane PUetc
ConnectionFlange;thread,tri-clamp
Body materialcarbon steel,SS304,SS316
Power supply220VAC,24VDC,Battery
OutputPulse;4~20mA;HART;RS485;RS232,MODBUS;GPRS
ProtectionIP65 or IP68
  

 

 

How to choose right electrode?

ElectrodeMedium
SS316Living Water, Industrial Water, Raw Water, Municipal Wastewater, Corrosive Weak Acids, Alkali, and Salt Solutions
Hastalloy BSuitable for: non-oxidizing acids such as hydrochloric acid with a concentration of less than 10%, sodium hydroxide with a concentration of less than 50%, ammonia hydroxide solution of all concentrations; phosphoric acid and organic acids;
Not suitable for: Nitric acid
Hastelloy CSuitable for: mixed acid (such as mixed solution of chromic acid and sulfuric acid); oxidizing salts (such as seawater, Cu+++, Fe+++)
Not suitable for: hydrochloric acid
Titanium

Suitable for: salt (such as chloride, sodium salt, potassium salt, ammonia salt, hypochlorite, seawater), potassium hydroxide, ammonium hydroxide, hydrazine hydroxide solution with a concentration of less than 50%;

Not Suitable: hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid and other reducing acids;

Tantalum

Suitable for: hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid); chlorine dioxide, ferric chloride, hypochlorous acid, sodium chloride, lead acetate, etc.; nitric acid (including fuming nitric acid Oxidizing acid), aqua temperature below 80°C;

Not suitable for:alkali, hydrofluoric acid

Platinum

Suitable for :Almost all acid and alkali salt solutions (including oleum and fuming nitric acid)

Not suitable for:aqua regia, ammonia

Tungsten carbide

Suitable for :Pulp, sewage, mud, can resist the interference of solid particles

Not suitable for: Inorganic acids, organic acids and chlorides

 
Factory Show

BOQU Instrument was found since 2007, now BOQU has more 70 staff and engineers and has core technology of electrodes and develope more 50+ software for various controllers by self.

 

Installation

Applications of water hose flow meter:  water, wastewater, mining, mineral processing, power, pulp and paper, and chemical industries. Food, beverage, pharmaceutical, cooling water, metals processing, fertilizers, inorganic chemicals fertilizers ,soda , aqueous acid solutions,aqueous alkaline solutions, polymer chemicals, water-soluble adhesives, liquid containing solid matters, concrete slurries, mortar, slurry of solid matter, Water and wastewater applications include custody transfer of liquids in force mains between water/wastewater districts. Magnetic flowmeters are used in water treatment plants to measure treated and untreated sewage, process water, water and chemicals. Mining and mineral process industry applications include process water and process slurry flows and heavy media flows.

How to select right water hose flow meter ?
The key questions which need to be answered before selecting a magnetic flow meter are:
Is the fluid conductive or water based?
Is the fluid or slurry abrasive?
Do you require an integral display or remote display?
Do you require an analog output?
What is the minimum and maximum flow rate for the flow meter?
What is the minimum and maximum process pressure?
What is the minimum and maximum process temperature?
Is the fluid chemically compatible with the flow meter wetted parts?
What is the size of the pipe?
Is the pipe always full? 

Certifications

BOQU was found since 2007, now has more 70 staff and engineers, instruments has be exported to over 75 countires.,Now BOQU has been named as High-Tech Enterprice by goverment,ISO,CE, SGS is our common certicates. the core technology of electrode ,controller and 50+ software property is our based. all instruments has been recognized by National Metrology Bureau.there is many small factories in China, you should be carefully if they provide you very low price. this is tips for you in free.

Exhibitions

BOQU has a strong Develope Department and can develope many new instruments or technology, so we will hold 5~8 exhibitions in China or Foreign to show our results.

Why to choose BOQU?

Why to choose BOQU water hose flow meter?

1.National High-tech Enterprises Certificates,it's only 1%  company can get it in China.

2.Instruments has been exported to over 70 countries.

3.BOQU has more 50+ Softwares property

4.100% QC inspection Before Shippment.

5. ISO,CE,SGS standard and factory price.

6.All instruments has been 100% recognized by Bureau of National  Metrology

Contact

SHANGHAI BOQU INSTRUMENT CO.,lTD

Conact:Michael Luo

Email:Michael@shboqu.com

Whatsapp/Mob:86-15000087545

Factory address:No.118 xiuyan road,pudong district ,shanghai china, zip code:201315

You May Like
Not exactly what you want? 1 request, multiple quotations Get Quotations Now >>
You May Like