By-pass function HRV high external static pressure double filters green air purifier

FOB Reference Price:Get Latest Price
US $200-1,000 / Sets | 1 Set/Sets order unlimited (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Power Source:
Electrical
Type:
air filtration
Installation:
ceiling install
Certification:
CE, EMC, SASO
Capacity (CFM):
88
Power (W):
24
Voltage (V):
220
Place of Origin:
Beijing, China (Mainland)
Brand Name:
HOLTOP
Model Number:
XHBQ-D1.5DMTH
Airflow:
150cmh, 10 speeds
Heat exchanger type:
crossflow plate heat exchanger
External static pressure:
70pa
purification:
pm2.5, F9
Energy recovery:
total heat
Application:
house, office, school, restaurant
Noice level:
31.5dB(A)
Motor:
DC
Net weight:
25kg
Clients:
Hitachi, Midea, Mitsubishi and Gree
Supply Ability
Supply Ability:
1000 Set/Sets per Month optional
Packaging & Delivery
Packaging Details
wood platen packaging, polystyrene foam. 5/6 sets per pallet.
Port
Tianjin,Guangzhou etc

 

Energy Recovery Ventilatior with Smart Controller

By-pass function high external static pressure double filters green air purifier

 

 

Product Description

WHY CHOOSE A ERV (ENERGY RECOVERY VENTILATOR)

An energy recovery ventilator system (ERV) fits in colder climates, in the homes where there is no excess moisture in heating season, as well as for homes located in warmer climates where the outside humidity level is high.

 

As for the HRV system, the ERV system recovers heat; however, it also recuperates the energy trapped in moisture, which greatly improves the overall recovery efficiency.

 

In air conditioned homes, when it is more humid outside than inside, the ERV system limits the amount of moisture coming into your home. In humidified homes, when the humidity level is low in winter, the ERV system limits the amount of moisture expelled from your home.

 

 Feature:

-  Airflow various from 150-2000m3/h

- Double high efficient filters

- Operating theatre clean class material

- Filtration class is up to F9, passing national GB/T 14295 standards

Sensible and latent heat recovery

- Quiet operation

- Lower energy consumption 

 

 

 

 

SELECTION GUIDE

1. Choose the proper installation types based on the building structure

2. Determine the fresh airflow required according to the use, size and number of persons

3. Select the right specifications and quantity according to the determined fresh airflow

 

 

 

Example

The area of a computer room is 60 sq. meters (S=60), the net height is 3 meters (H=3), and there are 10 per-sons (N=10) in it.

If it is calculated according to “Personal fresh air consumption”, and assume that: Q=70, the result is

Q1 =N*Q=10*70=700(m3/h)

If it is calculated according to “Air changes per hour”, and assume that: P=5, the result is

Q2 =P*S*H=5*60*3=900(m3)

Since Q2 > Q1 , Q2 is better for selecting the unit.

 

As to special industry such as hospitals (surgery and the special nursing rooms), labs, workshops, airflow re-quired should be determined in conformity with regulations concerned.

 

  

 

 

 

Intelligent Type(Optional)

1.Temperature LED display. 

2.Automatic bypass
3.Electrical heater
4.Defrosting
5.External ON/OFF
6.CO2 concentration control
7.Smart alarm
8.Data memory
9.Weekly timer
10.Airflow adjustment 

 

 

Application

 

Factory profile

Holtop is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 2002, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Beijing Olympic and Shanghai Expo 2010, works together with domestic and international brands like Midea, Haier, Hitachi, etc.

 

 

Packaging

Packing

1.Dust Proof Film + Anti-collision Foam + 5-6 Layer Cartons + Ply-wooded Pallets

2.Customized packing is available.

Shipping

1. Express delivery

2. Air flight

3. Sea shipment

4. Railway transportation

5. Multimodal transportation

 

 

Our service

A. All-round technical supports

1.We help to select models based on your requirements.

2.We provide professional product schemes and technical reports.

3.We design and develop the new products according to your requirements.

4. We provide professional advice for your installation, debugging and operation.

5. We supply the spare parts and technical support in & after the warranty time.

6. General testing and operational test carried out for every units before delivery.

7. We supply the training service at our factory if you need.

B. Reliable after-sales service

1. Technical advice for commissioning, installation, operation and maintenance.

2. Free spare parts for replacement during warranty period.

3. Or 1% free spare parts as warranty for container delivery.

C. Customized service

1. OEM service

2. ODM service

3. New product R&D service

4. CKD & SKD

 

Contact

 

 

 

 

Holtop energy recovery ventilator keep your home cleaner and healther.

 

 

Let's improve indoor air quality together!!