notice Note: Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order. close

Free Shipping DSO4072C 2 Channel Digital Oscilloscope,DSO4072C 1 Channel Arbitrary Waveform Generator

  • 1 Pieces
    $339.00
  • 2-3 Pieces
    $329.00
  • >=4 Pieces
    $299.00
Quantity:
- + Pieces available
0piecesselected, US $in total
View Details
Shipping fee:
Depends on the order quantity.
Lead Time:
4 day(s) after payment received
Contact Supplier
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Graigar
Model Number:
DSO4072C
Bandwidth:
70MHz
Pulse Width Range:
20ns ~ 10s
Readout Resolution:
6 digits

Packaging & Delivery

Selling Units:
Single item
Single package size: 
40X20X16 cm
Single gross weight:
6.000 kg
Package Type:
standard export carton
Lead Time :
Quantity(Pieces) 1 - 30 >30
Est. Time(days) 4 To be negotiated

DSO4072C 2 Channel Digital Oscilloscope DSO4072C 1 Channel Arbitrary Waveform Generator

 

 

Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Overtime Trigger 
Over Time ModeRising edge or Falling edge
Time Range20ns ~ 10s
Alternative Trigger 
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter 
Readout Resolution6 digits
Accuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeAC coupled, from 4Hz minimum to rated bandwidth
Signal SourcePulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.