Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
Huawei
Model Number:
MA5616
Type:
DSLAM
Surge Protection:
GE/FE: 6 kV , POTS: 4 kV
AC Power:
220V/110V
DC Power:
-48V
User-side Ports:
ADSL2+, VDSL2, POTS, G.SHDSL, ISDN
Power consumption:
<63W
Operating temperature:
-40°C to +65°C
Operating humidity:
5% RH to 95% RH
Dimension:
88.1 mm x 442 mm x 245 mm
Full configuration weight:
7.2 kg
Supply Ability
Supply Ability:
300 Piece/Pieces per Week Huawei Smartax MA5616
Packaging & Delivery
Packaging Details
Original ZTE carton package
Port
Shanghai
Lead Time :
Shipped in 7 days after payment

Original Huawei Smartax MA5616 CCUB CCUC CCUD Supports ADLE/ADPE/ASRP/ASPB

 

Product Description

 

 

The SmartAX MA5616 Multi-service Access Module (MA5616) is a board-pluggable box-type device of 2 U high and 19 inch wide. It supports service access in ultra-high bandwidth and flexible service expansion.
The MA5616 provides the following user ports: asymmetric digital subscriber line 2 plus (ADSL2+), very-high-speed digital subscriber line 2 (VDSL2), single-pair high-speed digital subscriber line (SHDSL), plain old telephone service (POTS), integrated services digital network (ISDN). It can be used in fiber to the building (FTTB), fiber to the curb (FTTC), and dedicated line access scenarios, and can also be used as a mini digital subscriber line access multiplexer (DSLAM) or a multiservice access node (MSAN) to provide traditional voice, data, and video services.

  

Appearance

 

 

 

 

 

 

 

 

 

 

Features

 

1) High access density: The MA5616 supports a maximum of 256 POTS users, 128 ADSL2+ users, 192 VDSL2 users, or 64FE users. The MA5616 supports 128 POTS users and 128 ADSL2+ users simultaneously by using a combo board.

 

2) Flexible configurations: Service boards are slot compatible and different types of ports can be configured flexibly, improving the actual configuration ratio and meeting different customer requirements.Support for the combo board to improve the access density, reduce the space of the equipment room, and simplify cable routing complexity. Support for the P2P optical access board (4GE+4FE) to provide high bandwidth for valued customers. Support for 48-V backup power (lead-acid batteries and LiFePO4 batteries).

 

3) Operable IPTV services: Strong service switching capability, packet forwarding capability, and high integration (data exchange and user management) enable the MA5616 to have carrier-class multicast operation capability.

 

4) Perfect voice features, supporting basic services (voice service, fax service, and modem service) and supplementary services (three-way calling, call waiting, call transfer, calling line identification presentation, and calling number restriction).

 

 

Classification

Feature

10G gigabit-capable passive optical network (GPON)

10G GPON is a next-generation PON standard defined by International Telecommunication Union - Telecommunication Standardization Sector (ITU-T). It provides asymmetric upstream and downstream rates, with a maximum upstream rate of 2.5 Gbit/s and a maximum downstream rate of 10 Gbit/s. 10G GPON uses the following key technologies:
  • Burst optical/electric
  • Ranging
  • Forward error correction (FEC)
  • Line encryption
  • Dynamic bandwidth assignment (DBA)

Vectoring

The Vectoring technology uses Vectoring algorithms to cancel inter-line crosstalk for multi-pair very-high-speed digital subscriber line 2 (VDSL2) lines so that VDSL2 line bandwidths can be increased significantly. In this technology, the Vectoring control entity (VCE) uses various technologies to cancel inter-line crosstalk in upstream and downstream directions:
  • Downstream: pre-coding technology
  • Upstream: canceling technology

Layer 2 management

  • MAC address management
  • Virtual local area network (VLAN) management
  • Flow bundle
  • Layer 2 forwarding policies
    • Outer VLAN+MAC forwarding
    • Service VLAN (SVLAN)+customer VLAN (CVLAN) forwarding
  • Layer 2 isolation
  • Layer 2 bridging
  • Transparent transmission of protocol packets
  • 1:1 virtual MAC address (VMAC)

Quality of service (QoS)

  • Priority processing
  • Congestion management
  • Traffic policing
  • Service priority marking
  • Queue scheduling
  • Queue buffering
  • Traffic shaping
  • Access control list (ACL) policies

Emulation services

  • Point-to-Point Protocol over Ethernet (PPPoE) dialup emulation
  • Dynamic Host Configuration Protocol (DHCP) dialup emulation
  • Multicast service emulation

Layer 3 features

  • VLAN Layer 3 interface
  • Address Resolution Protocol (ARP)
  • Domain name service (DNS) client
  • Static route

Voice services

  • Voice over IP (VoIP)
    • Public switched telephone network (PSTN)
    • Integrated services digital network (ISDN) basic rate access (BRA)
  • Fax over IP
  • Modem over IP

Networking features

  • Multiple Spanning Tree Protocol (MSTP)
  • Link Aggregation Control Protocol (LACP)
  • PON type B protection

User security

  • Policy Information Transfer Protocol (PITP)
  • DHCP option82
  • Anti-MAC address flapping
  • Anti-MAC address spoofing
  • Anti-IP address spoofing
  • Access user isolation
  • Ring check

System security

  • Source IP address filtering
  • Source MAC address filtering
  • Destination MAC address filtering
  • Anti-denial of service (DoS) attack
  • Anti-IP packet attack
  • Anti-Internet Control Message Protocol (ICMP) packet attack
  • Source route filtering
  • Firewall
  • Blacklist

Operation and maintenance security

  • User account and password management
  • Authentication, encryption, and access control based on Simple Network Management Protocol (SNMP) v3
  • Setting of an independent security administrator
  • Encryption for file transfer
  • Encryption for remote management and connection
  • Logging of security events

Line security

  • Advanced Encryption Standard (AES) 128 encryption for GPON downstream transmission

 

 
 
Service Board/ Port

 

Board Type

Abbreviated Name

Description

Function

Control board

CCUE

Central control unit board

Aggregates upstream services, manages the device, and manages the service of each interface module.

Service board

ASRB

32-port narrowband service board

Supports the voice over IP (VoIP) and plain old telephone service (POTS) services.

ASPB

64-port narrowband service board

Supports the VoIP and POTS services.

DSLD

8-port integrated services digital network (ISDN) service board

Supports ISDN service access in eight channels. Four ISDN ports can connect to one base transceiver station (BTS), and each DSLD board can connect to two BTSs.

ADLE

32-port asymmetric digital subscriber line 2 plus (ADSL2+) service board

Supports ADSL2+ over POTS service access in 32 channels and has a built-in splitter.

CALE

32-port ADSL2+ and POTS service combo board

Supports ADSL2+ and POTS service access each in 32 channels.

CVLC

32-port very-high-speed digital subscriber line 2 (VDSL2) and POTS service combo board

Supports VDSL2 and POTS service access each in 32 channels.

VDGE

16-port VDSL2 over POTS service board

Supports VDSL2 over POTS service access in 16 channels. It supports the following frequency spectrum profiles: 8a, 8c, 8d, 12a, 12b, 17a, and 30a.

VDSH

24-port VDSL2 over POTS service board

Supports VDSL2 over POTS service access in 24 channels. It supports the following frequency spectrum profiles: 8a, 8b, 8c, 8d, 12a, 12b, and 17a.

VDTH

24-port VDSL2 over ISDN service board

Supports VDSL2 over ISDN service access in 24 channels. It supports the following frequency spectrum profiles: 8a, 8b, 8c, 8d, 12a, 12b, and 17a.

VDSE

24-port VDSL2 over POTS service board

Supports VDSL2 over POTS service access in 24 channels and has a built-in splitter. It supports the following frequency spectrum profiles: 8a, 8b, 8c, 8d, 12a, 12b, and 17a.

VDLE

32-port VDSL2 over POTS service board

Supports VDSL2 over POTS service access in 32 channels and has a built-in splitter. It supports the following frequency spectrum profiles: 8a, 8c, 8d, 12a, 12b, and 17a.

VDLF

32-port VDSL2 service board

Supports VDSL2 service access in 32 channels and has a built-in splitter. It supports the following frequency spectrum profiles: 8a, 8c, 8d, 12a, 12b, and 17a.

VDMM

48-port VDSL2 over POTS service board

Supports VDSL2 over POTS service access in 48 channels. It supports metallic loop test (MELT) and the following frequency spectrum profiles: 8a, 8b, 8c, 8d, 12a, 12b, and 17a.

NOTE:

The VDMM board can only be used when a DC power board or an AC power board PAIC is configured on the MA5616.

VCMM

48-port VDSL2 service board

It supports the following functions:
  • 48 ports of VDSL2 over POTS access
  • 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles
  • Metallic loop test (MELT)
  • system-level Vectoring function
NOTE:

The VCMM board can be used only when the PDVAA DC power board is configured on the MA5616.

SHLH

16-port single-pair high-speed digital subscriber line (SHDSL) service board

Supports SHDSL service access in 16 channels and supports asynchronous transfer mode (ATM) SHDSL and Ethernet in the first mile (EFM) SHDSL access modes.

Power board

PAIA

AC power board

  • Converts the AC input into –48 V DC, +12 V DC, and +3.3 V DC, and does not support batteries.
  • Supports a total output power of 200 W.

PAIC

AC power board

  • Converts the AC input into –48 V DC, +12 V DC, and +3.3 V DC, and does not support batteries.
  • Supports a total output power of 400 W.

PAIB

AC power board supporting batteries

Converts the AC input into –48 V DC, +12 V DC, and +3.3 V DC, and supports batteries.

PDIA

DC power board

It is available in two models: H831PDIA and H832PDIA.
  • The H831PDIA board supports conversion of one -48 V DC input.
  • The H832PDIA board supports conversion of two -48 V DC inputs.
Both the power boards meet -48 V DC, +12 V DC, and +3.3 V DC power supply requirements of the MA5616.

PDVA

DC power input interface board

Converts dual channels of –48 V DC input into –48 V DC, +12 V DC, and +3.3 V DC to meet the power supply requirements of the chassis.

PDVAA

DC power input interface board

  • Supports one -48 V DC input.
  • Supports a total output power of 400 W.

Fan tray

FCBB

Fan control board

Fans are used to cool the system. This board provides an E2PROM circuit for storing the board manufacturing information.

The MA5616 can control and monitor fans and supports soft start of the fan tray.

 

 

Specification

 

Specifications

MA5616 (CCUB Control Board)

MA5616 (CCUC Control Board)

Dimensions (H x W x D)

88.1 mm x 442 mm x 245 mm

88.1 mm x 442 mm x 245 mm

Operating Environment

–40°C to +65°C

5% RH to 95% RH

–40°C to +65°C

5% RH to 95% RH

Power

AC: 220V/110V

DC: –48V

AC: 220V/110V

DC: –48V

Network-side Ports

Available configuration modes:

·1 x GPON + 1 x GE

·2 x GE

Available configuration modes:

·2x GPON;

·2 x GE

·1 x GPON + 1 x GE

User-side Ports

ADSL2+, VDSL2, POTS, G.SHDSL, ISDN

ADSL2+, VDSL2, POTS, G.SHDSL, ISDN, FE, GE

Surge Protection

GE/FE: 6 kV

POTS: 4 kV

GE/FE: 6 kV

POTS: 4 kV

 
 

 

 

Our Services

We sincerely invite all interested buyers to visit our company and contact us directly for further information, 

We are sure your any inquiry or requirement will get prompt attention.

 

 