tap water filter/water filter japan/activated carbon filter for swimming pool

FOB Reference Price:Get Latest Price
$2,000.00 - $5,000.00 / Pieces | 1 Piece/Pieces (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Shaanxi, China (Mainland)
Brand Name:
XST
Model Number:
XSTRO
features:
water ionizer/water purifier plant/reverse osmosis water filtration
reverse osmosis membrane:
ro membrane
operation:
manual or automatic
Usage:
seawater ionizer desalination/drinking water treatment plant
output water PH:
6.4~7.2
Inlet water temperature:
4~45℃
desalinaion rate/salt rejection rate:
98~99%
raw water:
well water , uder ground water, lake water, river water etc.
warranty:
12 months
recovery rate:
50~75%
Supply Ability
Supply Ability:
50 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
wooden case suitable for shippig
Port
Shanghai port

tap water filter/water filter japan/activated carbon filter for swimming pool 

2.ISO certificate,patents
3.One year warranty
4.12 years experience, water treatment solution provided

 Company instruction:

 Xi’an Xinshengtai (XST) Water Treatment Technology Co., Ltd. 

 (Formerly Xi’an Shengtaihuagong Science & Technology Co., Ltd.) was founded in 2003. 

 It’s an environmental friendly hi-tech company that specializes in research, production, and sale of water treatment equipment.

 Since established, XST has finished thousands of water treatment projects, involving chemical industry, power plant desalination 

 water, electrodeionization ultra pure water, medical industry, aviation cleaning, food and beverage industry, municipal heating, 

 softened circulating water, living water purification, brackish water desalination, sea water desalination, industrial waste water 

 treatment, reclaimed water reuse, rural area drinking water project, and etc. Xinshengtai Environmental Protection Industrial Park was built in 2011 in Xi’anXianyang New Area, which occupies 24,000 square meters. We now have 150 staff, with 50% of which have senior or advanced title. 

 And we established long term partnership with many universities and scientific research institutions in Xi’an. Our experienced and well trained staff can provide first class one stop services from on site investigation, project design, business 

 negotiation, installation and adjustment, to after sales service.

RO main component list:                                                                            

1.Standard back flushing pump(with electric machine)/inlet solenoid valve                                                 

 2.Back flushing dosing device/5μm precision filter/integrated membrane housing 

 4.Automatic chemical self washing mechanism/baking finish or S.S frame                                      

 5.Supervisory meters,such as concentrated water pressure gauge,flow meter,conductivity apparatus   

 6.Automatic control 

 Design basic data (For reference only,exact specification is subject to raw water and product):              

 1.Inlet water SDI(15 MINS):<5                                                                                                                     

 2.Inlet water TURBIDITY:<1.0NTU                                                                                                              

 3.Inlet water Fe:<0.005ppm                                                                                                                         

 4.Inlet water chlorine:(mg/l)<0.1                                                                                                                   

 5.Inlet PH:2~11                                                                                                                                             

 6.Inlet water temperature:4~45℃                                                                                               

 7.Desalination rate:95~99%                                                                                                                         

 8.Outlet water PH:5~7 

 9.Output water meet the WHO drinking standard

Standard system:

ModelCapacibilityOperationInletMembraneMembrane (QTY)RecoveryPower
(Tons/Hr)(MPa)Size(MM)Size(inch)(KW)
XSTRO-125L0.1251.0-1.4DN2040×21130%1.1
XSTRO-250L0.251.0-1.4DN2040×40150%1.1
XSTRO-500L0.51.0-1.4DN2040×40250%1.5
XSTRO-750L0.751.0-1.4DN2540×40360%2.2
XSTRO-1000L11.0-1.4DN2540×40460%2.2
XSTRO-1500L1.51.0-1.4DN2540×40660%3
XSTRO-2000L21.0-1.4DN2540×40860%3
XSTRO-250LDP0.251.0-1.4DN2040×40350%2.6
XSTRO-500LDP0.51.0-1.4DN2540×40550%3.7
XSTRO-1000LDP11.0-1.4DN2540×401060%5.2
XSTRO-2000LDP21.0-1.4DN2540×401660%7
XSTRO-2.52.51.0-1.4DN3240×401065%4
XSTRO-331.0-1.4DN3240×401265%4
XSTRO-661.0-1.4DN4080×40665%5.5
XSTRO-10101.0-1.4DN5080×401075%11
XSTRO-15151.0-1.4DN5080×401575%15
XSTRO-20201.0-1.4DN6580×402075%18.5

Technical Route:

Raw tank-->raw water pump-->quartz sand filter-->activated carbon filter-->water softer--> sediment filter (cartridge filter 5um )-->high pressure pump-->RO desalination device-->permeate water tank

What types of water sources does it treat?

Reverse Osmosis is an ideal water treatment solution in most types of water.tap water, also known as municipal sources, undergroundwater, which includes brackish water, and saltwater. The biggest distinction between these three types is the Total Dissolved Solids (TDS) content of each type. As a rule of thumb, the American Health Association requires that drinking water is under 2,000 PPM TDS.Reverse osmosis is often used in a tap water environment to reduce hardness, or the debris deposited in water from traveling in metal pipes. Total dissolved solids is often a target of water purification in tap water systems.Underground reservoirs of water are often brackish, meaning they contain large volumes of salt, but not enough to be considered salt water. Groundwater is most often purified for the agriculture industry, the mining industry. Groundwater is also a prized target of the bottling industry, because the unique mineral combinations often have an appealing taste.
Salt water reverse osmosis (sometimes referred to as desalination) is the turning of saltwater into drinking water. Ocean water has up to 45,000 PPM TDS. The biggest uses of desalination come in providing water in areas that lack a regular supply of fresh water. 

Is pretreatment necessary?

It is very important that feed water be preconditioned to protect the membranes from fouling causing premature failure.The membrane is constructed of a porous material that allows water to pass through, but rejects up to 99% of the dissolved solids at the surface. The dissolved salts are concentrated reject water (brine stream), where they are discharged to waste. Removing things prior is key to letting the RO system do what it was meant to do.As the RO System continues to operate, the dissolved and suspended solids in the feed water tend to accumulate along the membrane surface. If these solids are allowed to build up, they eventually restrict the passage of water through the membranes, resulting in a loss of throughput. (The throughput capacity of the membranes is commonly referred to as the flux rate, and is measured in gallons per square foot of membranes surface area per day.)
Is it necessary to get a water analysis?

A detailed chemical analysis (LSI, SDI, or CFI) of the RO feed water is an absolute necessity for identifying potential foulants. This should include a measurement of the hardness (calcium and magnesium), barium, strontium, alkalinity, pH, and chlorine. The data from the chemical analysis can be used by the engineers designing the system to determine the optimum 

membrane array that will both minimize the tendency of scale and deposit formation and maximize the recovery and flux rate.
What determines the precise pretreatments for a particular RO?

In one word: analysis. Every source of water is different, and you never know what's in your water until you have it analyzed. The water analysis, LSI, SDI, or CFI values are used to determine the precise pretreatment requirements for a particular RO System. Since water supplies vary considerably from one location to another, each pretreatment requirement will be different.
Does the feed water need to be softened by the RO?

Ion exchange is a popular method for softening and reducing the potential for mineral scale formation on the membrane surface. Ion exchange softening uses sodium to replace scaleforming ions such as calcium, magnesium, barium, strontium, iron, and aluminum to prevent damage to the membrane elements. The sodium forms very soluble salts, which are readily rejected by the Reverse Osmosis System and do not readily form mineral scales on the membrane surface. A sodiumcycle softener is regenerated with sodium chloride brine. The spent regenerant, along with the softener rinse water, must be discharged to waste. It is because of this that ion exchange is recommended for applications that have high metal contents in the treated water.

 Is acid injection necessary?

 Just as acidic solutions aren't good for membranes, caustic solutions are equally damaging to membrane elements. Acid injection may be incorporated into the RO pretreatment system to control pH and minimize the scale-forming tendency of the feed water. Acid injection is indicated if the scale forming tendency of the brine stream is above +0.3 as measured by the LSI. Either sulfuric or hydrochloric acid can be used for this purpose. 

 What does an antiscalant do?

Antiscalants have been shown to be effective in extending the intervals between chemical cleanings of the RO membranes. These products are generally formulated to include inorganic phosphates, organophosphates, and dispersants. Some Antiscalant contain negatively charged polymers and dispersants that can react with cationic polymers that might be dosed up stream prior to the media filters. The Antiscalant must be compatible with these polymers; otherwise, the reaction product 

will foul the membranes.

 Do all systems require chemical cleaning?

 Despite all efforts to protect the system from fouling and lose flux, eventually the membranes will require chemical cleaning. A welldesigned RO system will include provisions for a cleaning skid to facilitate the cleaning process. The skid should include a chemical tank, solution heater, recirculating pump, drains, hoses, and all other connection and fittings required for accomplishing a complete chemical cleaning of the RO modules.

Part of our projects:

1. boiler supply water of Kyrghyzstan Mining Base of CNPC 3*60m3/h(180m3/h)

and waste water reuse for boiler supply water 2*50T/H UF system and 2*40T/H RO system

2. Life water purification of Ukraine CC Company 24m3/D

3. Sea water desalination plant for Thailand IKKI Company 50m3/D

4.Ice-making process water for Tera Ice company from Australia,50m3/D

5. Fertilizer water for Australia, 24m3/D

6. 5000L/H pure water machine for Kenya Noble construction Ltd.

7. 5T/H Water softener for Singapore ENSURE ENGINEERING PTE LTD

8. Kazakhstan 25T/H RO for beverage company

Boiler supply water of power plant, recycling water of boiler and conditioner

Boiler supply water of Xi’an Aircraft Manufacturing Co., Ltd is 2*45m3/H in 2009

Boiler supply water of Shan’xi Weinan Cogeneration Power Plant is 2*40m3/H in 2010

Boiler supply water of Shan’xi Fugu Taida power plant is 2*60m3/D in 2010

Boiler supply water of Qinghai Menyuan Power Plant is 2*25m3/H in 2010

Solar power supply water of Power Researching Institute of CAS is 2*5m3/H in 2011

Supply water of Qinghai Zhongkong Solar Energy Power Co., Ltd is 2*10m3/H in 2012

Boiler supply water of Kyrghyzstan Mining Base of CNPC is 3*60m3/h in 2013

Boiler supply water of Shanxi Baishui New Energy Thermal Power Company is 2*20m3/H in 2013

Heating plant recycling soften water of No.771 Research Institute of CASC is 50m3/h in 2010

Boiler soften water of Xi’an E-pang Palace and Kaiyue International Restaurant (Five Stars) is 20m3/h in 2009

Boiler soften water of Xi’an Zhonglou International Restaurant (Five Stars) is 10m3/h in 2009

Boiler soften water of Tongchuan Kingsun Coal Mining Company is 120m3/h in 2011

Heating plant recycling soften water of Lunxiu Base of Qinghai Oil Field is 30m3/h in 2011

Boiler soften water of Auxiliary Factory of Changqing Oil Field is 2400m3/D during 2011-2012

Life water improvement of China Cotton Group is 150m3/D in 2011

Life drink water improvement of Tuha Oil Field Base is 240m3/D in 2011

Life drink water improvement of Third Division of Agricultural Construction of Xinjiang Kashgar Area is 360m3/D in 2012

Life drink water improvement of First Division of Agricultural Construction of Xinjiang Aksu Area is 200m3/D in 2012

Life drink water improvement of Route Stations of Wuha Line of Urumchi Railway Bureau is 700m3/D in 2013

Life water improvement of Hami Wind Power Plant of Xinjiang Huadian Group (Stages I, II, III) is 150m3/D during 2012-2013

Life water purification of Ukraine CC Company is 24m3/D in 2013

Sea water desalting of Thailand IKKI Company is 50m3/D in 2013

 Reverse Osmosis system reference picture:

1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter

2. Multi-medium filter-- get rid of turbidity, suspended matter, organic matter, colloid, ect

3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.

4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.

5. Micron filter--prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um.

6. High pressure pump-- Provide the high pressure to RO membrane ro.

7.RO system--main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% ions.

8.Chemical cleaning system--clean the RO system whn the RO sysem function decline.

9.Electric Cntrol system--relay  ot PLC for your option

 

Certificates:


 Our Factory,package&shiping&office:

 Contact:

skype: fuchunli566
QQ 790491046
wechat: fuchunli002
phone: +86 18220481290

 

You May Like
Not exactly what you want? 1 request, multiple quotations Get Quotations Now >>
You May Like

Similar products in other categories: