Analog Gauss Meter: Complete Analysis of Standards, Types, and Industry Performance

Types of Analog Gauss Meters

An analog Gauss meter is a precision instrument used to measure the strength and direction of magnetic fields. These devices are essential in scientific research, industrial quality control, electronics, and safety inspections. Unlike digital models, analog Gauss meters use a physical needle or dial to display readings, offering real-time visual feedback that can be particularly useful in dynamic environments. Below is a comprehensive overview of the most common types of analog Gauss meters, their features, applications, and comparative advantages.

Standard Analog Gauss Meter

The most basic and widely used type, ideal for general magnetic field detection and routine checks.

Advantages
  • Simple, intuitive dial-based reading
  • Reliable for detecting normal to weak magnetic fields
  • Low maintenance and durable construction
  • Ideal for educational and basic industrial use
Limitations
  • Limited precision compared to advanced models
  • Not suitable for measuring very strong or very weak fields
  • Commonly found in older equipment with outdated calibration

Best for: Basic diagnostics, classroom demonstrations, older electronic devices

Graduated Scale Gauss Meter

Features a finely calibrated scale for improved accuracy and detailed magnetic field analysis.

Advantages
  • Precise readings with clear incremental markings
  • Excellent for observing gradual changes in field strength
  • Reduces human interpretation errors
  • Commonly used in controlled experimental settings
Limitations
  • Requires careful alignment and steady handling
  • More sensitive to external vibrations or movement
  • May need frequent recalibration for consistent accuracy

Best for: Laboratory experiments, calibration tasks, academic research

Dual Range Analog Gauss Meter

Equipped with a range switch to measure both weak and strong magnetic fields effectively.

Advantages
  • High versatility with two measurement ranges
  • Eliminates the need for multiple instruments
  • Efficient for fieldwork involving diverse magnetic environments
  • Common in industrial maintenance and safety inspections
Limitations
  • Range switching may introduce user error
  • Slightly bulkier design due to additional components
  • Accuracy may vary between ranges if not properly calibrated

Best for: Industrial diagnostics, multi-environment testing, maintenance crews

High Sensitivity Analog Gauss Meter

Engineered to detect minute fluctuations in magnetic fields with exceptional precision.

Advantages
  • Capable of detecting subtle magnetic variations
  • Essential for high-precision research and development
  • Minimizes measurement errors in sensitive applications
  • Used in semiconductor and aerospace industries
Limitations
  • Highly sensitive to environmental interference
  • Requires stable conditions and skilled operation
  • Premium cost due to advanced internal mechanisms

Best for: Scientific research, electronics manufacturing, magnetic material testing

Portability Analog Gauss Meter

Compact and lightweight design for convenient field measurements and on-site testing.

Advantages
  • Easy to carry and operate in remote locations
  • Maintains reliable accuracy despite smaller size
  • Ideal for outdoor equipment and moving machinery
  • Often battery-powered for uninterrupted use
Limitations
  • May have reduced durability under harsh conditions
  • Limited battery life in continuous-use scenarios
  • Smaller dials may be harder to read precisely

Best for: Field inspections, outdoor electrical systems, mobile maintenance teams

Type Sensitivity Precision Versatility Primary Applications
Standard Analog Low to Medium Basic Low General diagnostics, education
Graduated Scale Medium High Medium Laboratory testing, research
Dual Range Wide (Low to High) Medium to High High Industrial, multi-condition use
High Sensitivity Very High Very High Specialized R&D, electronics, aerospace
Portability Medium Medium High Fieldwork, outdoor inspections

Expert Tip: When using analog Gauss meters in the field, always ensure the device is properly zeroed before measurement and shielded from external magnetic interference (e.g., nearby motors or power lines) to maintain reading accuracy.

Features of Analog Gauss Meters

Analog Gauss meters are essential tools for measuring magnetic field strength with precision and reliability. Widely used in industrial, scientific, and educational environments, these instruments offer a range of benefits that make them particularly valuable for applications requiring real-time monitoring and high sensitivity. Unlike digital models, analog Gauss meters rely on mechanical movement to display readings, providing unique advantages in responsiveness and durability.

Direct Readout Analog System

The core component of an analog Gauss meter is its analog display, which uses a moving pointer across a calibrated scale to indicate magnetic field strength. This mechanical readout system provides immediate visual feedback, allowing users to observe fluctuations in the magnetic field in real time without processing delays.

This instantaneous response is especially beneficial when monitoring dynamic or fluctuating fields, as subtle changes become immediately apparent through pointer movement. Additionally, the analog nature of the display can reveal weak or transient magnetic signals that might be averaged out, filtered, or missed entirely by digital sampling systems, making it ideal for detecting intermittent magnetic anomalies.

Sensitivity in Low Magnetic Fields

Analog Gauss meters excel in detecting low-intensity magnetic fields due to the high sensitivity of their needle-based mechanism. Even minimal deflection of the pointer can indicate the presence of a weak magnetic field, enabling precise detection in environments where magnetic activity is faint or localized.

This capability is crucial in applications such as quality assurance in electronic manufacturing, troubleshooting electromagnetic interference (EMI), inspecting residual magnetism in components, and verifying degaussing processes. Their responsiveness makes them indispensable in laboratories and production facilities where precision at low field levels is required.

Robust Build and Durability

Designed for demanding environments, analog Gauss meters are built with rugged materials that withstand physical stress, vibration, and accidental drops. The absence of sensitive digital circuitry makes them less prone to failure from electrical surges or environmental factors like moisture and dust.

This durability ensures reliable performance in fieldwork, industrial plants, and maintenance operations where conditions are less than ideal. Whether used on construction sites, near heavy machinery, or in confined spaces, these meters maintain accuracy and functionality despite rough handling, making them a trusted choice for technicians and engineers working in challenging settings.

Battery Operation and Portability

Most analog Gauss meters are powered by standard batteries, eliminating the need for external power sources or cords. This battery-operated design enhances portability, allowing for convenient use in remote locations, outdoor environments, or mobile inspections.

Combined with their lightweight and compact form factor, this feature makes analog Gauss meters highly practical for on-site measurements, including large-scale magnetic system evaluations, field surveys, and equipment diagnostics. Their ease of transport and quick setup reduce downtime and increase operational efficiency in both routine checks and emergency troubleshooting scenarios.

Dial Scales with Multiple Measurement Ranges

Analog Gauss meters typically feature clearly marked dial scales calibrated in units such as Gauss (G) or Tesla (T), often with multiple ranges selectable via a range switch. These scales allow users to measure a wide spectrum of magnetic field strengths—from milligauss levels to several thousand Gauss—without requiring additional instruments.

The inclusion of multipliers and dual-unit markings enhances versatility, enabling seamless transitions between applications in research, industry, and education. This eliminates the need to carry multiple devices, streamlining workflows and reducing equipment costs while maintaining measurement accuracy across diverse use cases.

Visual Trend Interpretation

One of the most underrated advantages of analog meters is their ability to visually convey trends and patterns in magnetic fields. The continuous motion of the pointer allows users to intuitively assess the rate and direction of change, offering insights that numerical displays may obscure.

For example, oscillations, gradual increases, or sudden spikes in field strength are easily observable, aiding in diagnostics and real-time decision-making. This analog "trend visualization" supports faster analysis during experiments, equipment testing, or safety inspections, where understanding dynamics is as important as absolute values.

Feature Benefit Typical Applications
Direct Analog Readout Real-time response, visual trend tracking Magnetic field monitoring, lab experiments
High Sensitivity at Low Fields Detects weak or residual magnetism EMI troubleshooting, quality control
Rugged Mechanical Design Withstands harsh environments and impacts Field service, industrial maintenance
Battery-Powered & Portable No cords, easy transport On-site inspections, outdoor surveys
Multi-Range Dial Scales Flexible measurement across units and magnitudes Research, education, cross-disciplinary use

Note: While analog Gauss meters offer excellent sensitivity and durability, they require proper handling to maintain calibration. Avoid strong mechanical shocks, exposure to extreme temperatures, and prolonged exposure to very high magnetic fields, as these can affect accuracy. Always store the meter in a protective case and zero it before use when possible. For critical measurements, periodic calibration against a known standard is recommended to ensure long-term reliability.

Commercial Uses of Analog Gauss Meters

Analog Gauss meters are essential tools in various industrial and scientific applications where precise measurement of magnetic fields is required. These robust, easy-to-read instruments provide real-time analog feedback, making them ideal for field diagnostics, quality control, and equipment calibration. Below are the key commercial applications of analog Gauss meters, expanded for clarity and technical depth.

Checking Electric Motors for Usability

One of the most critical industrial applications of analog Gauss meters is in the maintenance and evaluation of electric motors. These devices measure the strength and uniformity of magnetic fields within motor components such as rotors, stators, and permanent magnets.

  • Technicians use Gauss meters to detect magnetic field degradation caused by overheating, demagnetization, or mechanical wear—common signs of impending motor failure
  • The analog display allows for immediate visual interpretation of field fluctuations, aiding in dynamic troubleshooting without reliance on digital interfaces
  • Regular magnetic field assessments help optimize motor efficiency, reduce energy consumption, and extend service life
  • Used in predictive maintenance programs to identify early-stage faults before catastrophic breakdowns occur

Key benefit: Enables non-invasive diagnostics of motor health, reducing downtime and repair costs.

Assessing Magnetic Materials in Manufacturing

In manufacturing environments, consistent magnetic performance is vital for products like hard disk drives, speakers, magnetic separators, and electric vehicle components. Analog Gauss meters are used to verify the magnetic strength and polarity of raw materials and finished components.

  • Ensures proper magnetization during production processes such as sintering, bonding, or magnetizing pulses
  • Verifies alignment and strength of multi-pole magnets used in motors and sensors
  • Supports quality assurance by detecting under-magnetized or inconsistently charged materials before assembly
  • Helps maintain compliance with industry standards (e.g., ISO 9001) for magnetic product consistency

Quality impact: Prevents defective products from reaching customers by ensuring magnetic specifications are met at every stage.

Checking Sensors and Transducers

Magnetic sensors—including Hall effect sensors, reed switches, and proximity transducers—rely on precise magnetic field interactions to function correctly. Analog Gauss meters are instrumental in testing and validating these devices.

  • Measures the sensitivity threshold and response linearity of magnetic sensors under controlled field conditions
  • Identifies faulty or underperforming sensors by comparing actual field readings to expected values
  • Facilitates quick bench testing during R&D or production line inspections
  • Supports calibration of sensor positioning relative to magnetic sources for optimal performance

Efficiency gain: Reduces manual inspection time and increases accuracy in sensor validation processes.

Calibration of Equipment

Accurate calibration of magnetic measurement equipment is crucial in industries ranging from aerospace to medical device manufacturing. Analog Gauss meters serve as reliable reference tools for calibrating magnetometers, inductive coils, and other field-sensitive instruments.

  • Provides a stable, real-time analog readout that can be compared against digital devices for verification
  • Used in conjunction with Helmholtz coils or standard magnetic fields to establish calibration baselines
  • Ensures traceability to national or international standards when properly certified
  • Maintains consistency across multiple test stations and shifts, minimizing measurement drift

Critical function: Guarantees data integrity and regulatory compliance in precision-dependent environments.

Mapping Magnetic Fields in Research

Scientific and engineering research often requires detailed spatial mapping of magnetic fields. Analog Gauss meters offer a practical solution for visualizing field distribution in real time.

  • Used in physics labs to study magnetic dipole configurations, solenoids, and permanent magnet arrays
  • Applied in geophysics for field surveys and mineral detection studies
  • Helps in designing magnetic shielding by identifying field leakage zones
  • Supports educational demonstrations with intuitive, continuous needle movement that illustrates field gradients

Research advantage: Immediate visual feedback enhances understanding of dynamic magnetic phenomena without data processing delays.

Additional Industrial Applications

Beyond the core uses, analog Gauss meters are employed in several niche but vital commercial roles:

  • Demagnetization Verification: Confirming successful demagnetization of tools, molds, and components after machining
  • Security Systems: Testing magnetic door sensors and alarm triggers in access control systems
  • Automotive Industry: Evaluating magnetic components in ABS sensors, electric power steering, and EV drivetrains
  • Recycling & Scrap: Sorting ferrous from non-ferrous materials using residual magnetism detection

Versatility: Analog meters remain valuable despite digital advances due to durability, simplicity, and resistance to electromagnetic interference.

Best Practice Tip: For optimal results, regularly calibrate analog Gauss meters using certified magnetic standards and store them away from strong magnetic sources to prevent zero-point drift. Pairing analog readings with digital logging (when available) provides both real-time insight and long-term data tracking.

Application Sector Primary Use Case Measurement Range (Typical) Key Benefit
Electric Motor Maintenance Performance & Wear Assessment 100 – 5000 Gauss Early fault detection, reduced downtime
Electronics Manufacturing Quality Control of Magnetic Components 50 – 3000 Gauss Ensures product reliability and consistency
Sensor Production Sensitivity and Stability Testing 10 – 2000 Gauss Improves accuracy and reduces defects
Industrial Calibration Reference Standard Verification 1 – 10,000 Gauss Maintains measurement traceability
Scientific Research Field Mapping & Experimentation 1 – 5000 Gauss Real-time visualization of field dynamics

Why Choose Analog Over Digital?

While digital Gauss meters offer data logging and high precision, analog models remain preferred in many commercial settings due to:

  • Instant Response: Needle movement provides immediate visual feedback on field changes, ideal for dynamic environments
  • Durability: Fewer electronic components make analog meters more resistant to shock, moisture, and EMI
  • No Power Dependency: Operates without batteries in passive models, suitable for remote or emergency use
  • User-Friendly: Simple interface reduces training time and minimizes operator error
  • Cost-Effective: Lower initial cost and maintenance make them ideal for small workshops and field technicians

How to Choose Analog Gauss Meters: A Comprehensive Buyer's Guide

Selecting the right analog Gauss meter is essential for accurate magnetic field measurement across scientific, industrial, and educational applications. Unlike digital models, analog Gauss meters provide continuous visual feedback through a needle display, making them ideal for observing fluctuating fields in real time. This guide breaks down the key selection criteria to help you choose the most suitable analog Gauss meter for your specific needs—ensuring reliability, precision, and long-term usability.

Important Note: Analog Gauss meters are sensitive instruments. Always handle with care, avoid exposure to extreme shocks, and store in a dry, temperature-controlled environment to preserve calibration and extend lifespan.

Key Factors When Choosing an Analog Gauss Meter

  1. Consider the Application

    Understanding your intended use is the first and most critical step in selecting an analog Gauss meter. Different applications demand different features and performance levels:

    • Research & Development: Requires high-sensitivity models capable of detecting subtle magnetic variations. Look for meters with fine-scale graduations and low noise interference.
    • Industrial Quality Control: Dual-range meters are ideal for environments where both strong and weak fields may be encountered, such as in motor assembly or transformer testing.
    • Education & Demonstration: Standard or graduated scale meters are preferred due to their simplicity, durability, and ease of reading for students.
    • Electric Motors & Magnetic Devices: Meters with linear analog scales allow for quick visual assessment of field strength without complex interpretation.

    Selecting a meter based on application prevents over-investment in unnecessary features or under-specification that could compromise results.

  2. Assess Magnetic Field Strength

    The expected range of magnetic field strength directly influences the type of analog Gauss meter you should choose:

    • Strong Magnetic Fields (e.g., permanent magnets, industrial equipment): A basic analog Gauss meter with a robust probe and higher range (e.g., 0–3000 Gauss) is sufficient. These models are less prone to overload and provide stable readings.
    • Weak Magnetic Fields (e.g., Earth's magnetic field, biomedical devices): Requires a highly sensitive instrument with micro-Gauss resolution. These meters often include amplification circuits and shielded probes to minimize external interference.
    • Variable Field Environments: Consider a dual-range or switchable scale meter to accommodate both high and low intensities without switching devices.

    Choosing a meter with an appropriate range ensures accurate detection without signal distortion or needle pegging, which can damage the instrument.

  3. Accuracy and Sensitivity

    Accuracy refers to how closely the meter’s reading matches the true magnetic field value, while sensitivity determines the smallest change it can detect:

    • For critical applications like laboratory research or aerospace testing, select a meter with certified accuracy (±1% or better) and high sensitivity (down to 0.1 Gauss or lower).
    • For general-purpose use such as motor inspections or magnetic shielding checks, a standard accuracy meter (±3–5%) with moderate sensitivity is adequate.
    • Check if the meter includes calibration certificates or supports user recalibration to maintain long-term reliability.

    Higher sensitivity often comes with increased fragility and cost, so balance precision needs with practicality.

  4. Select for Environmental Conditions

    The operating environment plays a major role in determining the durability and design of the Gauss meter:

    • Hazardous or Harsh Environments: Choose ruggedized models with dust-proof enclosures, moisture resistance (IP-rated), and temperature tolerance (e.g., -10°C to 50°C). These are essential for fieldwork or industrial plants.
    • Controlled Laboratory Settings: More delicate, high-precision analog meters can be used where environmental factors are regulated.
    • Electromagnetic Interference (EMI): Ensure the probe and circuitry are shielded to prevent false readings from nearby electrical equipment.

    A well-chosen meter will withstand its environment without compromising measurement integrity.

  5. Portability vs. Stability

    Decide whether your work requires mobility or benchtop stability:

    • Portable Meters: Lightweight, battery-powered, and often come with carrying cases. Ideal for on-site inspections, maintenance teams, and outdoor surveys. Look for ergonomic designs and shock-resistant housings.
    • Stationary/Benchtop Meters: Designed for precision and consistent use in labs. Typically powered by AC, with larger dials for easier reading and better damping to reduce needle oscillation.
    • Hybrid Options: Some analog meters offer both portability and stable mounting features, making them versatile for mixed-use scenarios.

    The right balance between portability and stability ensures efficient operation without sacrificing measurement quality.

Selection Criteria Best For Avoid If Recommended Features
Application Type Research, education, industrial QC Using a lab-grade meter in the field Dual-range, clear scale, application-specific calibration
Field Strength High (>1000G) or low (<10G) fields Mismatched range causes inaccuracy Adjustable range, overload protection
Accuracy & Sensitivity Precision measurements Over-specifying for simple tasks Calibration certificate, fine needle resolution
Environmental Conditions Dusty, wet, or hot environments Using non-rugged meters outdoors IP rating, sealed housing, wide temp range
Portability Needs Field inspections, mobile teams Needing high stability on a bench Battery operation, compact size, durable case

Expert Tip: Always test the analog Gauss meter with a known magnetic source (like a calibrated magnet) before deployment. This quick verification ensures the needle responds correctly and helps detect any calibration drift early.

Additional Selection Tips

  • Check probe type—axial and transverse probes serve different measurement orientations; choose based on how you’ll position the sensor.
  • Look for damped needle movement to reduce oscillation and allow for stable readings, especially in dynamic environments.
  • Ensure the scale is clearly marked with easy-to-read units (Gauss or Tesla) and includes a zero-adjust knob for calibration.
  • Consider future needs—selecting a slightly more capable meter can save costs over time by avoiding upgrades.
  • Verify availability of replacement probes and service support from the manufacturer.

Choosing the right analog Gauss meter doesn’t have to be overwhelming. By systematically evaluating your application, required accuracy, environmental conditions, and mobility needs, you can select a reliable instrument that delivers consistent, trustworthy results. Whether you're monitoring magnetic fields in a manufacturing plant or conducting physics experiments, the right analog Gauss meter enhances both efficiency and confidence in your measurements.

Frequently Asked Questions About Analog Gauss Meters

Q1: What Are the Basic Principles That Drive Analog Gauss Meters?

Analog Gauss meters operate based on the fundamental principles of electromagnetic induction and the Hall effect, which allow for the detection and measurement of magnetic fields. These instruments utilize specialized sensors—most commonly Hall effect elements or induction coils—to detect magnetic flux density.

  • Hall Effect Sensors: When a current-carrying conductor is placed in a magnetic field perpendicular to the current flow, a voltage (known as the Hall voltage) is generated across the conductor. This voltage is directly proportional to the strength of the magnetic field, enabling precise measurement.
  • Induction Coils: In dynamic applications, coils of wire generate an electromotive force (EMF) when exposed to changing magnetic fields. The magnitude of the induced voltage correlates with the rate of change and intensity of the magnetic field.
  • Measurement Output: The detected signal is processed through analog circuitry and displayed on a needle-based dial, providing real-time, continuous readings of magnetic field strength in units such as Gauss or Tesla.

These principles ensure that analog Gauss meters deliver reliable, quantitatively accurate measurements, making them essential tools in industrial, scientific, and educational environments.

Q2: Are There Any Kinds of Magnetic Fields That Analog Gauss Meters Cannot Detect?

While analog Gauss meters are engineered to detect a wide range of magnetic fields, including those generated by permanent magnets, electric currents, and ferromagnetic materials, certain limitations exist based on sensor type and instrument design.

  • Field Strength Limits: Each meter has a specific measurement range. Extremely strong magnetic fields (e.g., near MRI machines or industrial electromagnets) may exceed the upper limit, causing sensor saturation or inaccurate readings. Conversely, very weak fields (such as Earth’s natural magnetic field at ~0.5 Gauss) may fall below the detection threshold of less sensitive models.
  • Static vs. Dynamic Fields: Meters using induction coils can only measure changing (AC) magnetic fields, while Hall effect-based meters can detect both static (DC) and dynamic fields. Therefore, choosing the right sensor type is crucial depending on the application.
  • Frequency Response: Some analog meters are not designed for high-frequency alternating fields, limiting their use in RF or high-speed switching environments.

For extreme conditions, specialized high-range or ultra-sensitive Gauss meters are available, often calibrated for specific industrial or research applications. Always verify the specifications of the device to ensure compatibility with your measurement needs.

Q3: Can Analog Gauss Meters Work Well in Outdoor Applications?

Yes, analog Gauss meters are well-suited for outdoor use due to their durability, portability, and lack of reliance on digital components that may be sensitive to environmental fluctuations. They are commonly used in field inspections, electromagnetic compliance checks, and maintenance of outdoor electrical systems.

  • Rugged Design: Many analog models feature robust casings that protect against dust, vibration, and minor impacts, making them ideal for industrial and field environments.
  • Real-Time Readings: The analog needle display allows for immediate visual interpretation of magnetic field changes, which is especially useful when scanning large areas or monitoring fluctuating fields in real time.
  • Environmental Interference: Performance can be influenced by external magnetic sources such as power lines, vehicles, or buried metal structures. Users should take baseline readings in neutral zones and account for background interference.
  • Battery Independence: Unlike digital meters, some analog versions require no power source, enhancing reliability in remote locations.

For optimal outdoor performance, select a model rated for environmental resilience and consider using a non-magnetic tripod or holder to minimize user-induced interference during measurements.

Q4: How Does Humidity Affect Analog Gauss Meters?

Humidity typically has minimal impact on analog Gauss meters, especially those designed for industrial or field use. Most quality instruments are housed in sealed enclosures that prevent moisture ingress and protect sensitive internal components such as the sensor, coil windings, and mechanical movement of the meter needle.

  • Moisture Resistance: Sealed cases with gaskets or O-rings prevent condensation and water entry, preserving the integrity of electrical contacts and preventing corrosion.
  • Material Selection: High-end models use corrosion-resistant materials for internal components and coatings that resist oxidation in humid or marine environments.
  • User Recommendations: For prolonged use in high-humidity areas—such as tropical climates, underground facilities, or near water sources—it's advisable to choose a meter with an IP (Ingress Protection) rating indicating moisture resistance (e.g., IP54 or higher).
  • Maintenance Tip: After exposure to damp conditions, allow the meter to acclimate to dry air before storage to prevent internal condensation.

With proper selection and care, analog Gauss meters can maintain accuracy and longevity even in challenging environmental conditions.

Q5: How Often Should One Service Analog Gauss Meters?

Regular servicing is essential to maintain the accuracy, reliability, and lifespan of analog Gauss meters. While these instruments are generally low-maintenance due to their simple mechanical and electronic design, periodic calibration and inspection are critical—especially in precision-dependent applications.

  • Calibration Frequency: It is recommended to calibrate the meter annually under normal use. In high-precision or industrial settings (e.g., aerospace, quality control, or R&D), calibration every 6 months is advisable to ensure measurement traceability and compliance with standards.
  • Cleaning: Dust, dirt, and magnetic debris can accumulate on the sensor tip or dial mechanism. Clean the exterior and sensor area with a soft, dry cloth; avoid solvents unless specified by the manufacturer.
  • Functional Checks: Periodically verify the zero point and response using a known magnetic source. If the needle sticks, responds sluggishly, or fails to return to zero, internal servicing may be required.
  • Repair Needs: Physical damage, exposure to extreme fields, or long-term wear may affect the meter movement or sensor alignment. Such issues should be addressed by qualified technicians to restore accuracy.

Keeping a service log and adhering to a preventive maintenance schedule ensures that your analog Gauss meter remains a trustworthy tool for accurate magnetic field assessment over time.