Types of Flexim Flowmeters
Flexim flowmeters are advanced non-invasive ultrasonic flow measurement devices widely used across industrial, commercial, and municipal applications. Known for their clamp-on design and high accuracy, Flexim meters offer reliable flow monitoring without requiring pipe cutting or process interruption. Understanding the different types helps businesses select the right model for their specific fluid, pipe, and environmental conditions.
Ultrasonic Flow Meters
These are the foundational technology behind most Flexim devices. They operate by transmitting high-frequency ultrasonic signals through the pipe wall and into the fluid. By measuring the time difference between upstream and downstream signal travel, the meter calculates the average fluid velocity and derives the volumetric flow rate.
Advantages
- Non-invasive installation (clamp-on)
- No pressure drop or flow obstruction
- High accuracy (±0.5% to ±1%)
- Suitable for a wide range of pipe sizes
- Ideal for temporary or permanent monitoring
Limitations
- Requires clean, homogeneous fluids for best results
- Signal quality can be affected by pipe material or lining
- Higher initial cost compared to mechanical meters
Best for: Water, wastewater, chemicals, and HVAC systems where minimal maintenance and high reliability are critical.
Time-of-Flight (TOF) Flowmeters
Also known as transit-time meters, TOF flowmeters use two ultrasonic transducers mounted on opposite sides of the pipe. One sends a signal with the flow, the other against it. The time difference between the two signals is directly proportional to the fluid’s velocity. This method is highly accurate for clean liquids and gases.
Advantages
- Exceptional accuracy for clean fluids
- Bidirectional flow measurement
- Low maintenance with no moving parts
- Effective in large-diameter pipes
- Real-time digital output and diagnostics
Limitations
- Performance degrades with suspended solids or bubbles
- Requires a minimum fluid conductivity and homogeneity
- Installation alignment is critical
Best for: Potable water, oils, solvents, and compressed air systems where precision and long-term stability are essential.
Cross-Correlation Flowmeters
This advanced method uses two ultrasonic sensors placed at a known distance apart. It analyzes the time delay between similar flow "signatures" (natural turbulence or introduced markers) detected by each sensor. By correlating the signals, the system calculates the fluid’s velocity with high repeatability, even in challenging conditions.
Advantages
- Highly effective in turbulent or non-uniform flows
- Less sensitive to flow profile disturbances
- Works well in partially filled pipes
- Robust in varying fluid conditions
Limitations
- More complex signal processing required
- Higher cost due to advanced electronics
- May require calibration for specific applications
Best for: Wastewater, slurry transport, and industrial processes with fluctuating flow profiles.
Shallow Detection Flowmeters
Designed for applications where deep signal penetration is not possible or desirable. These meters use high-frequency ultrasonic pulses that travel a short distance through the pipe wall and fluid. The reflected signal is analyzed to determine flow velocity, making them ideal for thin-walled or lined pipes.
Advantages
- Effective on lined or coated pipes
- Minimal signal loss in thin materials
- Resistant to external noise and vibration
- Top-mounted transducers reduce sediment interference
Limitations
- Limited to smaller pipe diameters
- Less effective in highly attenuating fluids
- Requires precise sensor placement
Best for: Chemical processing, pharmaceutical lines, and lined pipelines where standard penetration would fail.
Doppler Flowmeters
Doppler flowmeters rely on the frequency shift of ultrasonic waves reflected by suspended particles or gas bubbles in the fluid. The difference between the transmitted and reflected frequency (Doppler shift) is used to calculate fluid velocity. This makes them uniquely suited for dirty or aerated liquids.
Advantages
- Excellent for slurries, wastewater, and aerated fluids
- Does not require clean, homogeneous flow
- Effective in high-solid-content applications
- Simple principle with reliable output in dirty conditions
Limitations
- Inaccurate in clean fluids (no reflectors)
- Measurement depends on particle concentration and size
- Lower accuracy compared to TOF meters (±2–5%)
Best for: Mining, sewage treatment, pulp and paper, and any application with particulate-laden fluids.
| Type | Fluid Compatibility | Accuracy | Best Pipe Size | Key Applications |
|---|---|---|---|---|
| Ultrasonic (General) | Clean liquids & gases | ±0.5% – ±1% | 15 mm – 6 m | Water, HVAC, Chemicals |
| Time-of-Flight (TOF) | Clean, homogeneous | ±0.5% – ±1.5% | 25 mm – 5 m | Potable water, oils, compressed air |
| Cross-Correlation | Turbulent, variable | ±1% – ±2% | 50 mm – 3 m | Wastewater, slurry, industrial |
| Shallow Detection | Thin-walled/lined pipes | ±1% – ±2% | 10 mm – 1 m | Pharmaceuticals, lined pipes |
| Doppler | Dirty, bubbly, slurry | ±2% – ±5% | 25 mm – 2 m | Sewage, mining, pulp |
Expert Tip: For optimal performance, ensure proper transducer mounting and coupling. Use manufacturer-recommended ultrasonic gel and follow surface preparation guidelines to maximize signal transmission, especially on corroded or painted pipes.
Industrial Applications of Flexim Flowmeters
Flexim flowmeters are advanced ultrasonic flow measurement devices widely adopted across multiple industries due to their non-invasive design, high accuracy, and ability to handle challenging fluid conditions. These clamp-on flow meters offer real-time monitoring without requiring system shutdowns, making them ideal for critical industrial processes where reliability and efficiency are paramount.
Key Advantage: Flexim flowmeters use time-of-flight ultrasonic technology to measure flow externally, eliminating the need for pipe cutting or process interruption. This feature ensures minimal maintenance, reduced downtime, and long-term cost savings.
Oil and Gas Industry
Application Overview
The oil and gas sector involves complex processes—from extraction and refining to transportation—where precise flow measurement is essential for operational efficiency, regulatory compliance, and financial accountability. Inaccurate readings can lead to significant revenue loss, safety risks, or environmental hazards.
Why Flexim Excels
Flexim flowmeters are engineered to handle extreme conditions common in this industry, including high pressures, varying temperatures, and abrasive or multiphase fluids. They accurately measure crude oil, natural gas, condensate, and refined products such as diesel and gasoline—even in pipelines with limited access or corrosive environments.
Their non-intrusive design prevents contamination and avoids pressure drops, while advanced signal processing ensures reliable data in turbulent or low-flow conditions.
Chemical Industry
Challenges in Chemical Processing
Chemical manufacturing involves a wide range of fluids with varying properties—highly corrosive acids, viscous polymers, volatile solvents, and reactive compounds. These substances often operate under extreme temperatures and pressures, making flow measurement both critical and difficult.
Solution with Flexim
Flexim flowmeters are compatible with a broad spectrum of chemical media without risk of sensor degradation. Since they clamp onto the outside of the pipe, there is no contact with the fluid, eliminating corrosion and contamination risks.
They provide stable, repeatable measurements across varying viscosities and densities, supporting batch control, reaction monitoring, and transfer operations with high precision.
Water and Wastewater Management
Flow Challenges in Water Systems
Water and wastewater infrastructure often features irregular piping layouts, partially filled pipes, and turbulent flow profiles. Additionally, water has low ultrasonic reflectivity, which traditionally challenges ultrasonic devices. Sediment buildup and variable conductivity further complicate measurement accuracy.
Flexim’s Adaptive Performance
Flexim flowmeters utilize advanced signal processing algorithms to overcome poor acoustic conditions. They function effectively in partially filled pipes, large-diameter conduits, and non-standard pipe materials like concrete or PVC.
Used in treatment plants, pumping stations, and distribution networks, they enable accurate monitoring of influent, effluent, and sludge flows—supporting regulatory reporting, leak detection, and energy optimization.
Pulp and Paper Industry
Complex Fluid Dynamics
The pulp and paper industry deals with highly viscous and fibrous slurries containing wood fibers, fillers, and recycled materials. These mixtures are abrasive, prone to clogging, and difficult to measure using conventional mechanical or electromagnetic flowmeters.
Reliable Measurement with Flexim
Flexim flowmeters excel in measuring thick, heterogeneous flows without clogging or wear. Their external sensors are unaffected by solids content or coating buildup inside the pipe.
They are used to monitor black liquor, green liquor, whitewater, and chemical dosing streams, ensuring consistent quality, optimizing chemical usage, and reducing waste in papermaking processes.
Power Generation
Critical Flow Monitoring Needs
In power plants—whether fossil fuel, nuclear, or renewable—accurate flow measurement is vital for safety, efficiency, and emissions control. Key applications include steam flow in turbines, cooling water circulation, boiler feedwater, and fuel delivery (gas, oil, or biomass slurries).
Advantages of Non-Intrusive Technology
Traditional inline flowmeters require system shutdowns for installation and maintenance, leading to costly downtime. Flexim flowmeters eliminate this issue by mounting externally, allowing for quick deployment and continuous monitoring.
They perform reliably in high-temperature steam lines and aggressive cooling water environments, providing real-time data for process optimization, predictive maintenance, and compliance with environmental standards.
| Industry | Typical Fluids Measured | Key Benefits of Flexim Flowmeters |
|---|---|---|
| Oil & Gas | Crude oil, natural gas, refined fuels, condensate | Handles multiphase flow, high pressure, remote locations; no process interruption |
| Chemical | Acids, solvents, polymers, caustics | Corrosion-resistant (no contact), wide viscosity range, safe for hazardous zones |
| Water & Wastewater | Raw water, treated effluent, sludge, stormwater | Works in irregular pipes, partial flow, low-reflectivity media |
| Pulp & Paper | Pulp slurry, black liquor, whitewater, process chemicals | Unaffected by solids, fibers, or coatings; no clogging |
| Power Generation | Steam, cooling water, boiler feedwater, fuel gas/oil | No shutdowns for installation, works in high-temp environments |
Note: For optimal performance, proper sensor placement, surface preparation, and calibration according to pipe material and fluid type are essential. Always consult technical specifications and application guides before deployment to ensure measurement accuracy and system compatibility.
Key Features of Flexim Flowmeter
Flexim clamp-on ultrasonic flowmeters represent a cutting-edge advancement in flow measurement technology, combining precision, durability, and non-invasive operation. These meters are engineered for industrial, commercial, and scientific applications where reliability, accuracy, and minimal maintenance are critical. Below is a detailed breakdown of the key features that make Flexim flowmeters a preferred choice across diverse sectors.
Durability and Long Life
Flexim clamp-on flowmeters are built for longevity, even in the most demanding environments. Constructed with robust materials and advanced sealing, they resist corrosion, vibration, and extreme temperatures. Unlike traditional inline meters that degrade from direct fluid contact, Flexim’s ultrasonic sensors are mounted externally, eliminating wear from abrasive or corrosive media.
- Zero internal wetted parts prevent erosion and chemical degradation
- Proven performance in harsh industrial settings, including chemical plants and metal processing facilities
- Resistant to scaling, clogging, and fouling—common issues with mechanical flowmeters
- Capable of measuring aggressive fluids like molten metals, slurries, and caustic chemicals without sensor damage
Key advantage: Extended service life reduces downtime and replacement costs, offering a superior return on investment.
High Measurement Accuracy
Flexim flowmeters deliver exceptional accuracy across a wide range of flow rates and fluid types. Utilizing time-of-flight ultrasonic technology, they calculate flow velocity by measuring the difference in sound wave travel time between upstream and downstream transducers—without any physical intrusion into the pipe.
- Typical accuracy of ±0.5% to ±1.0% of reading, surpassing many inline mechanical and electromagnetic meters
- Unaffected by changes in fluid viscosity, density, or conductivity
- Calibrated to meet international standards (e.g., ISO, NIST traceable)
- Consistent performance in bidirectional flow applications
Technical insight: Advanced signal processing compensates for pipe material, wall thickness, and temperature variations, ensuring reliable readings under fluctuating conditions.
Non-Intrusive Measurement
One of the most significant advantages of Flexim flowmeters is their non-invasive design. The sensors clamp directly onto the exterior of the pipe, eliminating the need for cutting, welding, or process shutdowns during installation.
- No process interruption—ideal for critical or continuous operations
- Maintains pipe integrity and avoids potential leak points
- Enables temporary or permanent installation without modifying piping systems
- Suitable for hazardous or high-pressure environments where intrusive installation is unsafe
Ideal for: Retrofitting existing systems, monitoring sealed or insulated pipelines, and applications involving toxic or sterile fluids.
Real-Time Monitoring & Data Integration
Flexim flowmeters are equipped with intelligent transmitters that support real-time data acquisition, visualization, and remote monitoring. This enables operators to make immediate, data-driven decisions for process optimization and leak detection.
- Outputs include 4-20mA, pulse, Modbus, and Ethernet/IP for seamless integration with SCADA and PLC systems
- Onboard diagnostics provide alerts for flow anomalies, sensor issues, or signal loss
- Compatible with cloud-based monitoring platforms for enterprise-wide visibility
- Supports data logging and historical trend analysis for compliance and reporting
Smart feature: Instantaneous flow data can be viewed on local displays or transmitted to control rooms and mobile devices for continuous oversight.
Why Flexim Stands Out in Flow Measurement
The Flexim flowmeter is not just a tool—it's a benchmark in non-invasive flow technology. With decades of innovation, Flexim has established itself as an industry leader by delivering customizable, high-performance solutions for complex measurement challenges.
- Innovation Leadership: Pioneered clamp-on ultrasonic technology for industrial applications
- Custom Engineering: Offers tailored configurations for unique pipe sizes, materials, and fluid types
- Global Trust: Used in oil & gas, water treatment, power generation, and manufacturing worldwide
- Future-Ready: Supports Industry 4.0 integration with IoT connectivity and predictive analytics
Pro tip: For optimal performance, pair Flexim meters with proper pipe preparation and calibration services to ensure long-term accuracy.
| Feature | Benefit | Typical Application |
|---|---|---|
| External Clamp-On Design | No process shutdown for installation | Retrofit projects, emergency monitoring |
| High Accuracy (±0.5%) | Reliable billing, custody transfer | Water distribution, fuel transfer |
| Corrosion & Abrasion Resistant | Long-term reliability in harsh media | Chemical processing, mining slurries |
| Real-Time Data Output | Immediate response to flow changes | Leak detection, process control |
Expert Recommendation: When selecting a flowmeter for critical applications, consider Flexim’s non-intrusive solution for its combination of precision, durability, and ease of installation. It’s particularly advantageous in environments where system integrity, safety, and uptime are paramount. For applications involving extreme temperatures or exotic pipe materials, consult Flexim’s engineering support for optimal sensor placement and configuration.
How To Choose a FLEXIM Flowmeter: A Comprehensive Buyer’s Guide
Selecting the right FLEXIM flowmeter is essential for achieving accurate, reliable, and efficient flow measurement across industrial applications. As a leader in ultrasonic flow measurement technology, FLEXIM offers advanced clamp-on and inline solutions designed for diverse environments. This guide outlines the key factors to consider when choosing a FLEXIM flowmeter to ensure optimal performance, longevity, and compliance with industry standards.
Important Note: Always consult with a FLEXIM application specialist or refer to technical datasheets before finalizing your selection. Environmental conditions, fluid properties, and installation constraints can significantly impact performance and compatibility.
1. Accuracy Requirements
Accuracy is one of the most critical parameters when selecting a flowmeter, especially in industries where precise measurement directly affects safety, efficiency, or financial outcomes.
- High-Precision Applications: Industries such as chemical processing, pharmaceuticals, and custody transfer require flowmeters with exceptional accuracy (±0.5% or better). FLEXIM’s advanced signal processing ensures minimal deviation even under fluctuating flow conditions.
- General Monitoring: In applications like cooling water circulation or wastewater treatment, slightly lower accuracy (±1.0% to ±1.5%) may be acceptable. FLEXIM provides scalable options to match budget and performance needs.
- Industry Standards: Ensure the selected model complies with relevant standards such as ISO, API, or OIML, depending on your region and application.
Pro Tip: For custody transfer or billing applications, choose models with built-in diagnostics and data logging to support audit trails and regulatory compliance.
2. Pipe Material Compatibility
Unlike many traditional flowmeters, FLEXIM’s clamp-on ultrasonic technology is non-invasive and highly adaptable to various pipe materials—without requiring process shutdowns.
- Compatible with metal pipes (steel, stainless steel, copper), plastic pipes (PVC, PP, PE), and glass-lined or coated pipes.
- Specialized transducer designs and coupling techniques allow accurate measurements even on challenging materials with varying acoustic properties.
- Eliminates the risk of leaks, contamination, or pipe damage associated with intrusive installations.
Before selection, verify the wall thickness, diameter, and surface condition of the pipe. FLEXIM provides online calculators and technical support to confirm compatibility.
3. Installation and Maintenance Considerations
FLEXIM flowmeters are renowned for their ease of installation and minimal maintenance requirements, making them ideal for retrofitting or temporary monitoring.
- Clamp-On Design: No cutting, welding, or process interruption required. Sensors mount externally using straps or weldable bases.
- Quick Setup: Most installations can be completed in under an hour with basic tools.
- Low Maintenance: No moving parts mean no wear, clogging, or need for recalibration under stable conditions.
- Remote Monitoring: Many models support digital outputs (4–20 mA, Modbus, HART) and integration with SCADA systems for real-time data access.
This makes FLEXIM an excellent choice for hard-to-access locations, hazardous environments, or processes that cannot tolerate downtime.
4. Heat and Pressure Tolerance
Industrial environments often involve extreme temperatures and pressures, particularly in oil refineries, petrochemical plants, and power generation.
- FLEXIM flowmeters are engineered to operate in temperatures from –40°C to +600°C (–40°F to 1112°F), depending on transducer type and insulation.
- Pressure ratings are determined by the pipe itself, not the meter—since the device is non-intrusive, it can handle systems operating at very high pressures without modification.
- High-temperature kits and protective housings are available for demanding applications.
Always confirm the thermal expansion characteristics of the pipe and ensure proper sensor mounting to maintain signal integrity at elevated temperatures.
5. Fluid Density and Viscosity
One of FLEXIM’s key advantages is its ability to measure a wide range of fluids regardless of density or viscosity changes.
- Effectively measures low-viscosity fluids like water, solvents, and liquefied gases.
- Equally capable with high-viscosity media such as crude oil, bitumen, syrups, and slurries.
- Unaffected by changes in fluid composition, density, or conductivity—ideal for multiphase or variable-quality streams.
- Advanced algorithms compensate for flow profile distortions caused by viscosity variations.
This versatility eliminates the need for multiple meter types across complex facilities, reducing inventory and training costs.
| Selection Factor | Key Questions to Ask | FLEXIM Advantage | Recommended Models |
|---|---|---|---|
| Accuracy | What is the acceptable error margin? Is certification required? | Up to ±0.5% accuracy with diagnostic validation | FLUXUS G722, F704 |
| Pipe Material | Is the pipe metal, plastic, or lined? What is the wall thickness? | Non-invasive design works on nearly all materials | FLUXUS ADM 8000 series |
| Installation | Can the process be shut down? Is space limited? | No process interruption; compact sensor footprint | FLUXUS G532, F531 |
| Temperature/Pressure | What are the max operating T/P? Are thermal cycles frequent? | External sensors avoid exposure to internal conditions | FLUXUS HT series with insulation kits |
| Fluid Properties | Is the fluid clean, abrasive, or multiphase? Does viscosity vary? | Insensitive to fluid properties; handles slurry and foam | FLUXUS G724, F734 for challenging media |
Expert Recommendation: Use FLEXIM’s free site assessment service to evaluate your specific application. Their engineers can simulate performance based on pipe size, material, fluid type, and environmental conditions to recommend the optimal configuration.
Final Selection Tips
- Consider future scalability—choose models that support communication protocols for integration into digital plant systems.
- For critical applications, opt for dual-channel or dual-path meters to improve redundancy and accuracy.
- Ensure proper training for personnel on sensor placement, calibration checks, and data interpretation.
- Regularly verify readings against known benchmarks or portable test units to maintain confidence in measurement integrity.
By carefully evaluating your application against these five key criteria—accuracy, pipe compatibility, installation needs, environmental conditions, and fluid characteristics—you can confidently select the right FLEXIM flowmeter for reliable, long-term performance. With their non-intrusive design, broad applicability, and low lifecycle cost, FLEXIM meters offer a smart investment for modern industrial measurement challenges.
Frequently Asked Questions About Flexim Flowmeters
Yes, Flexim flowmeters offer several key advantages that set them apart in the flow measurement industry. Designed for versatility and ease of use, they are particularly valued for their non-invasive installation and adaptability across diverse environments.
- Portable & Easy Setup: These flowmeters can be quickly installed and moved between different pipe locations without requiring system shutdowns, making them ideal for temporary monitoring or multi-point measurements.
- Universal Pipe Compatibility: They work seamlessly with various pipe materials—including steel, PVC, copper, and even lined or coated pipes—without modification.
- Complex Environment Performance: Unlike many traditional flowmeters, Flexim devices excel in challenging setups such as limited-access areas, high-vibration zones, or pipes with irregular geometries.
- Multi-Industry Use: From oil and gas, chemical processing, and power generation to food and beverage, water treatment, and pharmaceuticals, Flexim flowmeters meet the precision needs of a wide range of sectors.
These benefits make Flexim a preferred solution for engineers and technicians who need reliable, flexible, and fast flow measurement without compromising system integrity.
No, one of the greatest advantages of Flexim flowmeters is their exceptionally low maintenance requirements. Because they are non-intrusive, there’s no contact with the flowing medium, which eliminates many common wear and clogging issues.
- No Internal Components: Since the sensors clamp externally, there are no parts inside the pipe to corrode, erode, or become obstructed by debris.
- Minimal Cleaning: Routine maintenance typically involves wiping the sensor faces and pipe surface to ensure good ultrasonic coupling and signal transmission.
- No Process Downtime: Maintenance does not require system shutdowns or pipeline modifications, reducing operational disruption.
- Long-Term Reliability: With no moving parts and sealed electronics, these flowmeters maintain accuracy and performance over extended periods with little to no servicing.
This low-maintenance design significantly reduces lifecycle costs and labor, making Flexim flowmeters a cost-effective choice for both temporary and permanent installations.
Absolutely. Flexim flowmeters are engineered to deliver consistent and accurate performance even in the most demanding industrial environments.
- High Pressure & Temperature Tolerance: They operate reliably in systems with extreme temperatures (from sub-zero to over 500°C with appropriate sensors) and high-pressure applications common in oil, gas, and chemical industries.
- Robust Build Quality: Constructed with durable materials and protective housings, they withstand exposure to moisture, dust, vibration, and mechanical shocks.
- Harsh Environment Use: Widely deployed in offshore platforms, refineries, and heavy manufacturing plants where equipment must endure corrosive substances and fluctuating loads.
- Fail-Safe Monitoring: Their consistent performance helps prevent system overloads, leaks, or inefficiencies by providing real-time, dependable flow data.
Trusted by plant operators and engineers worldwide, Flexim flowmeters prove their resilience daily in some of the toughest industrial settings.
Yes, Flexim flowmeters are highly versatile and capable of measuring a broad spectrum of liquid types with high accuracy.
- Wide Fluid Range: They effectively measure water, wastewater, crude oil, refined fuels, chemicals, slurries, viscous oils, and even cryogenic liquids.
- Transparency Independence: Unlike optical sensors, ultrasonic technology works equally well with clear, opaque, or aerated fluids, including those with suspended solids or bubbles (depending on model and setup).
- Customizable Solutions: Specialized transducers and signal processing algorithms allow optimization for challenging media like high-viscosity fluids or multiphase flows.
- No Flow Disturbance: The clamp-on design ensures the fluid remains unaltered, preserving product quality—especially important in food, beverage, and pharmaceutical applications.
This adaptability makes Flexim flowmeters an ideal choice for facilities handling multiple fluid types or those needing a single device for diverse process lines.
FLEXIM ultrasonic flowmeters stand out due to their advanced non-intrusive clamp-on technology, which fundamentally changes how flow is monitored compared to conventional devices.
| Feature | Traditional Flowmeters | FLEXIM Clamp-On Flowmeters |
|---|---|---|
| Installation | Requires cutting pipes, welding, or inline insertion; often needs system shutdown. | Clamps externally—no pipe modification or downtime required. |
| Intrusiveness | Invasive; internal parts contact fluid, risking contamination or wear. | Non-intrusive; no contact with fluid, preserving system integrity. |
| Maintenance | Frequent cleaning, part replacement, and recalibration due to internal wear. | Minimal maintenance—just external sensor checks and cleaning. |
| Material Compatibility | Often limited to specific pipe types or require special fittings. | Works with virtually all pipe materials and diameters. |
| Portability | Fixed installation; not easily moved. | Highly portable—ideal for audits, diagnostics, and temporary monitoring. |