Types of Hematology 3-Part Analyzers
A Hematology 3-part analyzer is an essential diagnostic instrument used in clinical laboratories to perform complete blood count (CBC) tests with a three-part white blood cell differential—typically categorizing neutrophils, lymphocytes, and monocytes. These analyzers are engineered to meet diverse operational needs across healthcare environments, from small clinics to large hospitals.
The choice of analyzer depends on the facility’s testing volume, required functionalities, and clinical focus. Below is a detailed breakdown of the main types of 3-part hematology analyzers available, their features, applications, and benefits.
With Viscosity Measurement
Advanced 3-part analyzers equipped with blood viscosity testing offer comprehensive hemorheological assessment alongside standard CBC parameters.
Advantages
- Provides insights into blood flow dynamics
- Supports early detection of circulatory disorders
- Useful for monitoring patients with hypertension, diabetes, or cardiovascular risks
- Enhances diagnostic depth without additional equipment
Limitations
- Higher cost due to integrated technology
- Requires specialized calibration and maintenance
- Limited availability in entry-level models
Best for: Cardiology clinics, metabolic disease centers, and research labs focusing on blood rheology
With Automated Cell Counter
These analyzers specialize in high-speed, precise cell counting with 3-part differentiation using flow cytometry or impedance-based methods.
Advantages
- High throughput for large sample volumes
- Minimizes human error through full automation
- Fast turnaround time (often under 1 minute per sample)
- Integrated quality control and data management systems
Limitations
- Less flexibility for manual review
- Higher initial investment
- Requires stable power and controlled environment
Best for: High-volume diagnostic labs, hospital central labs, and reference laboratories
With Coagulation Testing
Combines standard 3-part CBC analysis with basic coagulation parameters such as PT (Prothrombin Time) and APTT (Activated Partial Thromboplastin Time).
Advantages
- Enables comprehensive blood health evaluation in one platform
- Reduces need for multiple instruments
- Ideal for assessing bleeding/clotting disorders
- Improves workflow efficiency in emergency and critical care settings
Limitations
- Coagulation modules may be less detailed than standalone coagulometers
- Increased complexity in operation and training
- Higher maintenance demands
Best for: Emergency departments, intensive care units (ICUs), and general hospitals requiring rapid integrated diagnostics
Manual & Automated Combination
Offers dual-mode functionality—automated analysis for routine samples and manual mode for flagged or abnormal results requiring microscopic review.
Advantages
- Greater diagnostic accuracy with manual verification
- Cost-effective for mid-sized labs
- Supports training and education in hematology
- Flexible for both routine screening and complex case analysis
Limitations
- Slower processing for manually reviewed samples
- Requires skilled technicians for manual differentials
- Potential for human variability in interpretation
Best for: Teaching hospitals, community health centers, and laboratories needing both efficiency and detailed analysis
| Type | Key Features | Throughput | Ideal Setting | Best Use Case |
|---|---|---|---|---|
| With Viscosity Measurement | CBC + blood flow analysis | Medium | Specialty clinics, research | Monitoring circulatory health in chronic disease |
| With Automated Cell Counter | High-speed 3-part differential | High | Hospitals, reference labs | Large-scale screening and diagnostics |
| With Coagulation Tests | CBC + PT/APTT testing | Medium-High | Emergency rooms, ICUs | Comprehensive blood evaluation in acute care |
| Manual & Automated Combo | Dual-mode operation | Variable | Community labs, teaching facilities | Balanced workflow with manual oversight |
Expert Tip: When selecting a 3-part hematology analyzer, consider future scalability. Models with modular designs allow integration of additional functions (like reticulocyte counting or expanded coagulation panels) as your lab's needs evolve.
Industrial Applications of Hematology 3-Part Analyser
A hematology 3-part analyser, often referred to as a blood test machine, is a vital diagnostic instrument used across multiple industries. Its widespread adoption is driven by its high accuracy, operational efficiency, and ability to process large volumes of blood samples quickly and reliably. By classifying white blood cells into three main categories—neutrophils, lymphocytes, and monocytes—this analyser provides essential hematological data for clinical and industrial use.
Key Industrial Applications
Clinical Laboratories
In clinical pathology settings, the hematology 3-part analyser automates complete blood count (CBC) and differential white blood cell analysis. These tests are fundamental for diagnosing conditions such as anemia, bacterial and viral infections, inflammation, and hematological disorders like leukemia.
Due to their high throughput and precision, these analysers are ideal for busy diagnostic labs that handle hundreds of samples daily. Automation reduces human error, ensures consistency, and accelerates reporting, making them indispensable in modern medical diagnostics.
Hospitals and Healthcare Facilities
Hospitals rely heavily on hematology analysers for routine and emergency testing. In critical areas such as emergency departments, intensive care units (ICUs), and operating rooms, rapid blood analysis is crucial for timely diagnosis and treatment decisions.
The analyser’s ability to deliver real-time, accurate results supports immediate clinical interventions—such as detecting sepsis, monitoring post-surgical recovery, or managing chronic diseases—thereby improving patient outcomes and streamlining workflow in high-pressure environments.
Blood Donation Centers
In blood banks and donation centers, the 3-part analyser plays a critical role in donor screening and blood quality control. It evaluates key blood components including red blood cell (RBC) count, hemoglobin levels, white blood cell (WBC) distribution, and platelet counts.
This data helps determine donor eligibility by identifying anemia, infections, or abnormal cell counts. Ensuring donor health and blood safety minimizes risks for both donors and recipients, supporting safe transfusion practices and regulatory compliance.
Research Laboratories
Biomedical and academic research labs use hematology analysers to investigate blood-related diseases, immune responses, and genetic disorders. The consistent and reproducible data generated supports longitudinal studies, animal models, and experimental trials.
Researchers depend on these instruments to monitor hematological changes in response to treatments, environmental factors, or disease progression. Their reliability makes them a cornerstone in advancing understanding of conditions like sickle cell anemia, autoimmune diseases, and hematopoietic cancers.
Veterinary Clinics
Veterinary-specific hematology analysers are widely used to assess the health of companion animals, livestock, and exotic species. These devices are calibrated for different animal species, enabling accurate interpretation of blood parameters across dogs, cats, horses, and farm animals.
Veterinarians use the results to diagnose infections, anemia, dehydration, and organ dysfunction. Early detection through routine blood screening improves treatment success and animal welfare, especially in critical or geriatric cases.
Biotechnology & Pharmaceutical Industries
In drug development and clinical trials, hematology 3-part analysers are essential for monitoring the hematological safety and efficacy of new therapeutics. They provide detailed blood profiles of trial participants, helping researchers detect adverse effects such as bone marrow suppression or immune system alterations.
Pharmaceutical companies integrate these analysers into quality control and preclinical testing pipelines. Their ability to generate standardized, compliant data supports regulatory submissions and ensures that new drugs meet safety benchmarks before reaching the market.
| Industry | Primary Use | Key Benefits |
|---|---|---|
| Clinical Labs | Automated CBC and differential counts | High throughput, reduced turnaround time, consistent accuracy |
| Hospitals | Emergency and ICU diagnostics | Rapid results, supports critical decision-making |
| Blood Banks | Donor screening and blood safety | Ensures eligibility, prevents transfusion risks |
| Research Labs | Experimental and disease modeling studies | Reliable, reproducible data for scientific validation |
| Veterinary Clinics | Animal health diagnostics | Species-specific analysis, early disease detection |
| Pharma & Biotech | Drug safety and clinical trial monitoring | Regulatory compliance, toxicity screening |
Why the 3-Part Analyser Stands Out
Note: While hematology 3-part analysers provide excellent screening capabilities, abnormal or inconclusive results should be confirmed with manual blood smear review or advanced 5-part analysis when necessary. Always follow manufacturer guidelines for calibration, quality control, and maintenance to ensure diagnostic accuracy and regulatory compliance.
Product Specifications and Features of a Hematology 3-Part Analyser
A hematology 3-part differential analyser is a critical diagnostic tool used in clinical laboratories to perform complete blood count (CBC) tests efficiently and accurately. Designed for high-throughput environments, this automated blood testing machine streamlines hematological evaluations by delivering fast, reliable results with minimal manual intervention. Below is a detailed breakdown of its key features, installation, operation, and maintenance protocols.
Automated Analysis
The blood testing machine leverages automation to streamline the entire blood analysis process, significantly reducing the need for manual handling and minimizing human error—especially during high-volume blood work. This automation enhances laboratory efficiency and ensures consistent processing across multiple samples.
- Processes multiple samples sequentially with minimal user input
- Reduces turnaround time for CBC results in clinical settings
- Integrates with laboratory information systems (LIS) for seamless data transfer
- Features self-diagnostic functions to alert users of potential system errors
Key benefit: Increases lab productivity while maintaining high accuracy and repeatability.
3-Part Differential Capability
This analyser provides a comprehensive 3-part white blood cell (WBC) differential, categorizing WBCs into neutrophils, lymphocytes, and monocytes. It also delivers accurate counts and percentages for red blood cells (RBCs), platelets, and total WBCs, enabling quick and detailed hematological assessments.
- Essential for detecting infections, anemia, and immune disorders
- Supports early diagnosis and monitoring of chronic conditions
- Differentiates between bacterial and viral infections based on cell ratios
- Provides graphical representations (histograms) for better data interpretation
Clinical relevance: Offers actionable insights for physicians without requiring more complex 5-part analysers.
High Precision & Advanced Technology
Equipped with state-of-the-art detection systems, the analyser ensures high measurement accuracy through the use of the electrical impedance method for cell counting and chemical lysis and staining techniques for cell differentiation. These technologies work together to deliver consistent and clinically reliable results.
- Electrical impedance measures cell volume as they pass through a sensing aperture
- Chemical reagents lyse red blood cells and stain nucleated cells for accurate WBC classification
- Digital signal processing enhances resolution and reduces background noise
- Calibrated to meet international standards (e.g., CLSI, ICSH)
Technical advantage: Minimizes false positives and improves diagnostic confidence.
Multiple Hematological Parameters
The device can measure up to 20 different hematological parameters, making it a versatile tool for comprehensive blood analysis. These parameters are essential for evaluating overall health and diagnosing various medical conditions.
- Hemoglobin (HGB): Measures oxygen-carrying capacity of blood
- Hematocrit (HCT): Percentage of blood volume occupied by RBCs
- Mean Corpuscular Volume (MCV): Indicates size of red blood cells (microcytic vs. macrocytic anemia)
- Platelet Count (PLT): Assesses clotting ability
- White Blood Cell Differential: Neutrophils, lymphocytes, monocytes
- Red Cell Distribution Width (RDW): Reflects variation in RBC size
Diagnostic value: Enables identification of anemia types, infection stages, and bone marrow disorders.
Installation Guidelines
Proper installation is essential to ensure the hematology analyser functions optimally and safely. While a beta hCG blood test machine may share some environmental requirements, hematology analysers have specific setup needs due to their fluidic and electronic components.
- Place the analyser on a firm, level, and vibration-free surface to prevent misalignment
- Ensure adequate space around the unit for ventilation and maintenance access
- Connect to a stable power supply with surge protection
- Use distilled or deionized water for diluent preparation, as specified by the manufacturer
- Follow the step-by-step instructions in the user manual for initial calibration and system check
Pro tip: Perform installation during off-hours to avoid disrupting lab operations and allow time for system stabilization.
Operation Procedure
Trained professionals typically operate a complete blood count test analyser in clinical or hospital laboratories. The process is designed for ease of use while maintaining strict quality control.
- Label EDTA-anticoagulated blood sample tubes clearly to prevent mix-ups
- Load tubes into the sample rack in the correct order or barcode sequence
- Place the rack into the designated input slot on the analyser <4>Initiate the test by pressing the "Run" button or selecting the batch from the software interface
- Wait for automated processing (typically 30–60 seconds per sample)
- Review results on the screen or export to LIS for physician review
Best practice: Always verify sample integrity before loading—clotted or hemolyzed samples can skew results.
Maintenance & Quality Assurance
Regular maintenance is crucial for ensuring the longevity, accuracy, and reliability of the hematology analyser. A well-maintained system reduces downtime and ensures compliance with regulatory standards.
- Daily Maintenance: Clean the sample probe and mixing chamber; run a wash cycle using manufacturer-recommended cleanser
- Calibration: Perform daily or weekly calibration using standardized control materials
- Quality Control (QC): Run normal and abnormal control samples to validate system performance
- Weekly Tasks: Inspect tubing for blockages, check fluid levels, and clean external surfaces
- Monthly/Annual: Schedule technician visits for deep cleaning, sensor checks, and firmware updates
Important: Avoid using strong detergents or abrasive cleaners, as they can damage sensitive components and compromise test accuracy.
Expert Recommendation: Implement a preventive maintenance log to track all service activities. This not only extends the instrument's lifespan but also supports accreditation audits (e.g., ISO 15189, CAP). Always keep spare tips, filters, and reagents on hand to minimize operational delays.
| Parameter | Description | Measurement Method | Clinical Significance |
|---|---|---|---|
| WBC Count | Total white blood cells | Electrical Impedance | Infection, inflammation, leukemia screening |
| RBC Count | Red blood cell count | Electrical Impedance | Anemia, polycythemia |
| Hemoglobin (HGB) | Oxygen-carrying protein | Cyanide-free spectrophotometry | Assessment of oxygen delivery capacity |
| Platelets (PLT) | Clotting cells | Impedance or optical counting | Bleeding disorders, thrombocytopenia |
| 3-Part Diff | Neutrophils, Lymphocytes, Monocytes | Impedance + Lysing Reagents | Differentiating infection types and immune status |
Final Insight: The hematology 3-part analyser strikes an ideal balance between cost-effectiveness and diagnostic capability. It is particularly suited for mid-sized clinics, urgent care centers, and primary care labs that require reliable CBC testing without the complexity of a 5-part differential system. When paired with proper training and maintenance, it becomes an indispensable asset in modern healthcare diagnostics.
Quality and Safety Considerations of a Hematology 3-Part Analyzer
A hematology 3-part analyzer is a critical diagnostic instrument used in clinical laboratories to perform complete blood counts (CBC) and differential white blood cell analysis. Ensuring both quality and safety in its operation is essential for accurate patient diagnostics and the protection of laboratory personnel. This guide provides a comprehensive overview of key quality control practices and safety protocols to maintain optimal performance and workplace safety when using a 3-part hematology analyzer.
Important Note: Hematology analyzers process human blood specimens, which are classified as biohazardous materials. Strict adherence to quality assurance and safety procedures is mandatory to prevent exposure risks, ensure regulatory compliance, and maintain diagnostic accuracy.
Quality Considerations for Reliable Testing
Maintaining high-quality standards ensures that test results are accurate, consistent, and clinically reliable. Laboratories must implement systematic quality control measures to validate the performance of the hematology analyzer on a regular basis.
- Accuracy and Precision
The analyzer must consistently deliver results that are both accurate (close to true values) and precise (repeatable across multiple tests). To verify accuracy, laboratories routinely run certified reference materials with known cell counts and compare the analyzer’s output against established values. Precision is assessed through repeated testing of the same sample to evaluate variability. Acceptable limits for coefficient of variation (CV) are typically defined by the manufacturer and regulatory guidelines such as CLIA or ISO 15189.
- Quality Control Systems
Modern 3-part analyzers are equipped with integrated quality control systems that allow real-time monitoring of instrument performance. Daily use of commercial control materials—low, normal, and high-level controls—helps detect drift or malfunction early. Automated alerts, flagging systems, and trend analysis software assist in identifying subtle changes in performance before they impact patient results. Many instruments also support connectivity to Laboratory Information Systems (LIS) for seamless QC data tracking and audit trails.
- Reagent Quality and Management
The reliability of test results is directly influenced by reagent quality. Most manufacturers recommend using proprietary reagents specifically formulated for their analyzers to ensure compatibility, stability, and optimal performance. Reagents should be stored under recommended temperature and humidity conditions, used within expiration dates, and protected from contamination. Open reagent vials should be labeled with the date opened and monitored for degradation. Regular inventory checks and proper handling minimize the risk of erroneous results due to compromised reagents.
| Quality Parameter | Description | Recommended Frequency | Verification Method |
|---|---|---|---|
| Accuracy | How closely results match reference values | Daily or per batch | Use of calibrated control materials and reference samples |
| Precision | Consistency of repeated measurements | Daily | Multiple runs of the same sample; CV calculation |
| Carryover | Contamination between consecutive samples | Monthly or after maintenance | High-low-high sample testing protocol |
| Linearity | Ability to provide proportional results across concentration ranges | Quarterly or after major service | Dilution series testing |
| Reagent Integrity | Stability and effectiveness of reagents | Before each use | Visual inspection, expiration check, control testing |
Safety Considerations for Laboratory Personnel
Operating a hematology analyzer involves exposure to biological, chemical, mechanical, and electrical hazards. A robust safety program is essential to protect staff and maintain a compliant laboratory environment.
- Biohazard Safety
Blood and bodily fluids processed by the analyzer are potential sources of bloodborne pathogens such as HIV, HBV, and HCV. All specimens must be handled using Universal Precautions. Laboratory staff should wear appropriate personal protective equipment (PPE), including gloves, lab coats, and face protection when splash risks exist. Contaminated waste—including sample tubes, tips, and cleaning swabs—must be disposed of in designated biohazard containers. Regular decontamination of the analyzer’s sample probe, mixing chamber, and surrounding surfaces with approved disinfectants (e.g., 10% bleach or EPA-registered germicides) is critical to prevent cross-contamination and infection risks.
- Equipment Safety
The analyzer contains moving parts such as robotic arms, syringes, and stirring mechanisms that can pose entanglement or pinching hazards. A safety interlock cover should remain closed during operation to prevent accidental contact. Users must ensure all components—including reagent packs, waste containers, and sample racks—are correctly installed before starting the instrument. Routine maintenance and inspection help identify worn parts that could lead to mechanical failure or injury.
- Electrical Safety
To prevent electrical shock or fire hazards, inspect the power cord, plug, and outlet for damage before use. The analyzer must be connected to a grounded electrical outlet, and the use of surge protectors is recommended. Avoid placing liquids near electrical components. In the event of a spill or malfunction, immediately power off the device and unplug it before attempting cleanup or troubleshooting.
- Chemical Safety
The analyzer uses various chemical reagents—including lysing agents, diluents, and clean-up solutions—that may be corrosive, toxic, or irritant. These chemicals must be stored in clearly labeled, compatible containers in a well-ventilated area, preferably in a dedicated chemical storage cabinet. Safety Data Sheets (SDS) must be readily accessible to all staff. Proper handling procedures, including the use of gloves and eye protection, should be followed during reagent loading and waste disposal. Spill kits appropriate for the chemicals used should be available in the lab.
Best Practice Tip: Implement a daily startup checklist that includes QC testing, visual inspection of reagents, verification of waste levels, and confirmation of PPE availability. This proactive approach helps catch potential issues early and ensures consistent, safe operation of the hematology analyzer.
Additional Recommendations
- Train all operators thoroughly on both quality protocols and safety procedures before allowing independent use of the analyzer.
- Keep a maintenance log to document routine servicing, calibration, and any repairs.
- Participate in external quality assessment (EQA) or proficiency testing programs to benchmark performance against peer laboratories.
- Review incident reports and near-misses to improve safety culture and prevent recurrence.
- Ensure software updates and firmware upgrades are applied as recommended by the manufacturer to maintain optimal functionality and cybersecurity.
By integrating rigorous quality control practices with comprehensive safety measures, laboratories can ensure the hematology 3-part analyzer delivers accurate, reliable results while protecting the health and safety of laboratory professionals. Regular audits, staff training, and adherence to international standards such as ISO 15189 and OSHA regulations further strengthen the integrity of hematology testing operations.
Frequently Asked Questions About Hematology 3-Part Analysers
A hematology 3-part analyser is a medical diagnostic instrument designed to automate the analysis of blood components, significantly improving efficiency and accuracy in clinical laboratories. It primarily measures and differentiates blood cells into three main categories of white blood cells—neutrophils, lymphocytes, and monocytes—based on size and complexity.
This device provides a comprehensive evaluation of key hematological parameters, including red blood cell (RBC) count, hemoglobin concentration, hematocrit levels, platelet counts, and white blood cell (WBC) counts with a basic differential. These results are critical for diagnosing and monitoring a wide range of health conditions such as anemia, infections, leukemia, and other blood disorders.
While the system automates most of the process, minor manual interventions—such as sample loading or verification of abnormal results—may still be required. Due to its balance of functionality, cost-effectiveness, and reliability, the 3-part analyser is widely used in clinics, hospitals, and diagnostic centers.
Hematology analysers operate using advanced technologies such as flow cytometry and electrical impedance or laser light scattering to analyze blood samples at the cellular level. Here's how the process works:
- Sample Preparation: A small blood sample is collected and diluted with a special reagent to preserve cell integrity and facilitate accurate counting.
- Cell Analysis: The diluted sample passes through a narrow flow cell where it is exposed to a laser beam. As cells pass through the beam, they scatter light at different angles depending on their size, internal structure, and granularity.
- Data Interpretation: Detectors measure the scattered light and electrical signals, allowing the instrument to count and classify each cell type. The 3-part differentiation is based on the volume and complexity of white blood cells, grouping them into neutrophils, lymphocytes, and a combined category of monocytes and other less common types.
- Result Generation: The analyser compiles the data into a complete blood count (CBC) report, which includes all relevant hematological parameters.
Note: The phrase "hcg blood test ranges" in your query refers to pregnancy hormone testing and is unrelated to hematology analysers. Hematology devices do not measure hCG (human chorionic gonadotropin); that function is performed by immunoassay analyzers.
A hematology 3-part analyser delivers a detailed profile of blood composition by measuring a wide array of parameters essential for clinical diagnosis. These include:
| Parameter | Description | Clinical Significance |
|---|---|---|
| Red Blood Cell Count (RBC) | Number of red blood cells per microliter of blood | Helps diagnose anemia or polycythemia |
| Hemoglobin (Hgb) | Oxygen-carrying protein in red blood cells | Indicates oxygen delivery capacity; low levels suggest anemia |
| Hematocrit (Hct) | Percentage of blood volume occupied by red blood cells | Assesses hydration status and red cell mass |
| Mean Corpuscular Volume (MCV) | Average size of red blood cells | Differentiates types of anemia (microcytic, macrocytic, normocytic) |
| Mean Corpuscular Hemoglobin (MCH) | Average amount of hemoglobin per red blood cell | Supports classification of anemia |
| Mean Corpuscular Hemoglobin Concentration (MCHC) | Concentration of hemoglobin in a given volume of red cells | Helps identify spherocytosis or iron deficiency |
| White Blood Cell Count (WBC) | Total number of white blood cells | Elevated levels may indicate infection, inflammation, or leukemia |
| WBC Differential (3-Part) | Distribution of neutrophils, lymphocytes, and monocytes | Helps distinguish bacterial vs. viral infections and monitor immune response |
| Platelet Count | Number of platelets involved in clotting | Low counts can lead to bleeding; high counts may increase clot risk |
| Red Cell Distribution Width (RDW) | Variability in red blood cell size | Useful in diagnosing mixed-deficiency anemias (e.g., iron and B12 deficiency) |
Note: The term "blood test for pregnancy" refers to hCG detection and is unrelated to hematology analysers. Hematology devices focus solely on cellular components of blood, not hormonal assays.
A complete blood count (CBC) is one of the most commonly ordered blood tests and follows a standardized procedure to ensure accurate and reliable results:
- Blood Collection: A healthcare professional draws a venous blood sample, typically from the arm, using a sterile needle. The sample is collected in a lavender-top tube containing EDTA, an anticoagulant that prevents clotting.
- Sample Labelling: The tube is immediately labelled with patient information, including name, ID, and collection date/time to maintain traceability and prevent errors.
- Transport to Lab: The sample is transported under appropriate conditions (room temperature, protected from light) to the laboratory for analysis.
- Instrument Loading: In the lab, technicians verify the sample and load it into the hematology analyser. Modern systems support batch processing and automatic sampling.
- Automated Analysis: The analyser processes the sample within minutes, performing cell counts, size measurements, and differentials using laser or impedance technology.
- Review and Reporting: Results are reviewed by a medical technologist. Abnormal values may prompt a manual blood smear review under a microscope for confirmation.
The final CBC report includes all measured parameters and is sent to the ordering physician for clinical interpretation. This test plays a vital role in routine check-ups, pre-surgical screening, and disease monitoring.
Proper calibration is essential to ensure the accuracy, precision, and reliability of test results. Calibration frequency depends on usage, manufacturer recommendations, and regulatory standards, but general guidelines include:
- Daily Calibration: Most labs perform calibration at the start of each workday, especially in high-volume settings, to ensure consistency across shifts.
- After Maintenance: Any major service, repair, or replacement of critical components (e.g., sensors, pumps) requires recalibration.
- When Reagents Are Changed: Switching to a new lot of reagents or diluents often necessitates calibration to account for minor variations in chemical composition.
- Periodic Verification: Even if daily calibration isn't required, many facilities run control samples (low, normal, and high) every 24 hours to verify performance.
- After Relocation: If the instrument is moved, recalibration ensures proper alignment and function.
Calibration involves running standardized control materials with known values and adjusting the instrument’s settings to match these benchmarks. Laboratories must maintain detailed calibration logs for quality assurance and accreditation purposes (e.g., ISO 15189, CLIA). Skipping or delaying calibration can lead to inaccurate diagnoses and compromised patient care.