Types of Lab Ultrasonic Vibration Sieves
A lab ultrasonic vibration sieve is an advanced separation tool used in industrial, medical, and scientific laboratories to analyze, classify, and purify particles in powders, granules, and fluids. By combining high-frequency ultrasonic waves with mechanical vibration, these sieves enhance particle dispersion, reduce agglomeration, and significantly improve sieving accuracy—especially for fine or cohesive materials.
Below is a detailed breakdown of the most common types of ultrasonic sieves, their applications, benefits, and ideal use cases.
Ultrasonic Vibrating Screens
These are the most widely used ultrasonic sieves, combining mechanical vibration with ultrasonic energy to efficiently separate fine powders and particles. They are particularly effective for materials prone to clogging or static buildup.
Advantages
- High efficiency for fine particle separation
- Prevents mesh blinding and clogging
- Fast processing time
- Ideal for high-volume testing
Limitations
- Higher energy consumption
- Requires regular maintenance
- Less suitable for very coarse materials
Best for: Powder processing, ceramics, pharmaceuticals, and nanomaterials
Ultrasonic Particle Size Analysis Sieves
Designed for precise particle size distribution analysis, these sieves use ultrasonic waves to break down agglomerates and ensure accurate measurement—critical in research and quality assurance.
Advantages
- Superior measurement accuracy
- Reduces human error in analysis
- Compatible with automated data logging
- Essential for R&D and regulatory compliance
Limitations
- Narrow application scope
- Higher cost due to precision components
- Requires calibration and skilled operation
Best for: Medical research, drug formulation, and laboratory testing
Ultrasonic Test Sieves
Used primarily in quality control labs, these sieves ensure product consistency by separating particles through calibrated mesh sizes, enhanced by ultrasonic vibrations for greater reliability.
Advantages
- Ensures batch-to-batch uniformity
- Improves repeatability of test results
- Compliant with ISO and ASTM standards
- Reduces false positives in contamination checks
Limitations
- Mesh wear over time affects accuracy
- Limited to dry or low-moisture samples
- Not ideal for sticky or viscous materials
Best for: Quality assurance in food, chemical, and material science industries
Ultrasonic Mesh Sieves
Equipped with ultra-fine mesh and ultrasonic transducers, these sieves are engineered for delicate separations in biotechnology and pharmaceutical applications, such as cell sorting or biomolecule purification.
Advantages
- Enables separation at microscopic levels
- Preserves integrity of sensitive samples
- High throughput for lab-scale processing
- Reduces sample loss during filtration
Limitations
- Fragile mesh requires careful handling
- Potential for mesh damage from abrasive particles
- Higher replacement cost
Best for: Biotech research, vaccine development, and protein isolation
Ultrasonic Contamination Detection Sieves
Specifically designed for detecting foreign particles in sensitive products, these sieves use enhanced ultrasonic sensitivity to isolate contaminants that traditional methods might miss.
Advantages
- High detection sensitivity
- Improves product safety and compliance
- Reduces risk of recalls
- Effective for trace-level impurities
Limitations
- Requires cleanroom-compatible setup
- Slower processing for high-sensitivity mode
- Specialized training recommended
Best for: Pharmaceutical safety, food quality inspection, and sterile manufacturing
Customized Ultrasonic Sieves
Built to meet unique research or industrial requirements, these sieves can be tailored in mesh size, frequency, amplitude, and chamber design for specific materials or processes.
Advantages
- Highly adaptable to niche applications
- Optimized for unusual particle shapes or sizes
- Supports innovation in experimental setups
- Can integrate with existing lab systems
Limitations
- Longer lead time for fabrication
- Higher cost than standard models
- Limited vendor support in some regions
Best for: Specialized research, pilot-scale production, and proprietary material processing
| Type | Primary Use | Accuracy | Speed | Industries Served |
|---|---|---|---|---|
| Ultrasonic Vibrating Screens | Particle separation | High | Fast | Pharma, Ceramics, Chemicals |
| Ultrasonic Particle Size Analysis Sieves | Size distribution analysis | Very High | Moderate | Medical, Research, Biotech |
| Ultrasonic Test Sieves | Quality control | High | Fast | Food, Chemical, Materials |
| Ultrasonic Mesh Sieves | Fine purification | Very High | Slow to Moderate | Biotech, Pharma, Nanotech |
| Ultrasonic Contamination Detection Sieves | Impurity identification | Extremely High | Slow | Pharma, Food, Cosmetics |
| Customized Ultrasonic Sieves | Tailored separation | Variable | Variable | Research, Specialty Manufacturing |
Expert Tip: For optimal performance, always calibrate your ultrasonic sieve before critical tests and use appropriate mesh covers to prevent particle loss. Regular cleaning with non-abrasive solutions helps maintain mesh integrity and prolongs equipment life.
Material & Design of Lab Ultrasonic Vibration Sieve
Lab ultrasonic vibration sieves are essential tools in particle size analysis, offering high precision and efficiency in separating fine powders and granules. The performance, durability, and suitability of these sieves depend significantly on the materials used in their construction. Each material brings unique advantages and trade-offs in terms of strength, corrosion resistance, weight, and compatibility with sensitive applications such as pharmaceuticals, food processing, and chemical analysis.
Common Materials Used in Ultrasonic Sieve Construction
Stainless Steel
The most widely used material in laboratory sieves, stainless steel offers excellent resistance to rust, wear, and chemical corrosion. Its high tensile strength ensures long-term durability, even under the constant stress of ultrasonic vibrations. The robust structure supports fine wire mesh with precise aperture sizes, enabling accurate particle separation down to micrometer levels.
In addition to mechanical resilience, stainless steel features a smooth, non-porous surface that minimizes particle adhesion and simplifies cleaning—critical for preventing cross-contamination between samples. This makes it ideal for use in regulated industries like pharmaceuticals, biotechnology, and food quality control where hygiene and repeatability are paramount.
Carbon Steel
Carbon steel is a cost-effective alternative to stainless steel, offering good structural strength at a lower price point. While it lacks the inherent corrosion resistance of stainless steel, it remains suitable for applications in dry, non-corrosive environments. Carbon steel sieves are commonly used in industrial labs handling inert or non-reactive materials such as sand, cement, or certain minerals.
To enhance longevity, these sieves can be coated with protective layers such as epoxy, zinc plating, or powder coating. These treatments improve resistance to moisture and oxidation, extending service life without compromising sieve performance. However, care must be taken to avoid damage to the coating during cleaning or operation, as exposed areas can rust quickly.
Ceramics
Ceramic-based ultrasonic sieves are designed for specialized applications requiring extreme hardness, thermal stability, and zero metal contamination. Made from advanced materials like alumina or zirconia, ceramic sieves excel in environments involving highly abrasive powders or aggressive chemicals that degrade metallic components.
Due to their non-metallic composition, ceramic sieves are ideal for industries where even trace metal particles can compromise product integrity—such as in pharmaceutical manufacturing, semiconductor processing, and high-purity food production. The smooth ceramic surface resists wear and is easy to sanitize, ensuring consistent performance and compliance with strict purity standards.
Aluminum Alloys
Aluminum alloys are chosen for their lightweight nature and moderate corrosion resistance, making them suitable for portable or frequently handled sieving equipment. Though not as strong as stainless steel, modern aluminum alloys (such as 6061 or 7075) are engineered with additives like magnesium and zinc to improve strength and fatigue resistance.
These sieves perform well in humid environments and resist oxidation due to the formation of a natural oxide layer. Their reduced weight decreases operator fatigue during repetitive sieving tasks and simplifies integration into automated systems. However, aluminum should be avoided when sieving highly abrasive or reactive materials, as it may degrade faster than steel or ceramic alternatives.
Polymer Composites
Polymer composite sieves—often made from reinforced plastics like nylon, polyethylene, or PTFE—are gaining popularity in laboratories requiring chemical inertness and flexibility. These materials are highly resistant to acids, alkalis, and solvents, making them perfect for corrosive sample types that would damage metal sieves.
Beyond chemical resistance, polymer composites allow for intricate mesh designs that enhance ultrasonic wave transmission, improving separation efficiency. They are also electrically insulating and non-magnetic, beneficial in sensitive analytical environments. While limited to low-to-moderate temperature applications, their lightweight, durable, and anti-static properties make them valuable in niche research and industrial settings.
| Material | Corrosion Resistance | Strength | Typical Applications | Limitations |
|---|---|---|---|---|
| Stainless Steel | Excellent | High | Pharmaceuticals, food, chemicals, general lab use | Higher cost than carbon steel; heavier |
| Carbon Steel | Low (improves with coating) | High | Dry industrial powders, construction materials | Prone to rust without protection; not suitable for wet environments |
| Ceramics | Excellent | Very High (hardness) | High-purity industries, abrasive materials | Brittle; susceptible to impact damage |
| Aluminum Alloys | Moderate to Good | Moderate | Portable sieves, humid environments, lightweight setups | Less durable under abrasion; not ideal for aggressive chemicals |
| Polymer Composites | Excellent (chemical-specific) | Low to Moderate | Corrosive materials, electrostatic-sensitive processes | Limited heat tolerance; lower mechanical strength |
Design Considerations for Optimal Performance
Important: Always select the sieve material based on your specific application requirements, including sample type, environmental conditions, and regulatory standards. Using an inappropriate material can lead to inaccurate results, equipment failure, or contamination. Regular inspection and proper cleaning protocols will extend the life of any sieve, regardless of material.
Commercial Use Cases of Lab Ultrasonic Vibration Sieves
Lab ultrasonic vibration sieves are advanced separation tools that utilize high-frequency ultrasonic waves to enhance particle sizing accuracy and improve screening efficiency. These systems overcome common challenges like particle agglomeration, mesh blinding, and static cling—issues that traditional sieving methods struggle with—making them indispensable across multiple high-precision industries. Their ability to separate fine powders down to micrometer levels ensures consistent product quality, safety, and regulatory compliance.
Pharmaceutical Industry Sieves
In pharmaceutical manufacturing, precise particle size distribution is critical for drug efficacy, bioavailability, and dosage consistency. Lab ultrasonic vibration sieves are used to screen active pharmaceutical ingredients (APIs), excipients, and powdered formulations with exceptional accuracy.
- Enable separation of particles as fine as 20–400 microns, ensuring uniform texture and dissolution rates
- Prevent cross-contamination during batch processing with closed-system designs
- Support compliance with FDA and GMP standards by maintaining batch-to-batch consistency
- Enhance absorption rates by eliminating oversized or undersized particles that could affect drug performance
Key benefit: Improved quality control in tablet and capsule production through precise granulometry
Food Processing Industry Sieves
Ultrasonic sieves play a vital role in food safety and product refinement, particularly in the processing of fine powders such as flour, spices, cocoa, and dairy ingredients. They efficiently remove contaminants while preserving product integrity.
- Detect and eliminate foreign particles like metal fragments, husks, or mineral impurities without damaging delicate food materials
- Maintain flavor and aroma consistency in spices by preventing particle degradation during sieving
- Ensure smooth texture in powdered foods like infant formula, protein supplements, and instant beverages
- Meet HACCP and ISO 22000 food safety standards with reliable contaminant detection
Pro tip: Ideal for allergen control by isolating trace particles in mixed-product facilities
Chemical Manufacturing Industry Sieves
Chemical producers rely on ultrasonic vibration sieves to maintain strict control over raw material purity and particle size distribution, which directly influence reaction kinetics, solubility, and end-product performance.
- Accurately separate catalysts, pigments, dyes, and specialty chemicals with narrow particle size tolerances
- Prevent clogging in production lines by removing oversized agglomerates before processing
- Ensure homogeneity in formulations for paints, adhesives, and coatings
- Support quality assurance protocols by identifying deviations in particle morphology
Critical advantage: Enhanced reproducibility in chemical synthesis due to consistent feedstock preparation
Metal Processing Industry Sieves
In metal powder production and additive manufacturing (3D printing), particle uniformity is essential for structural integrity, flowability, and sintering behavior. Ultrasonic sieves provide high-precision classification of metallic powders used in aerospace, automotive, and medical implants.
- Classify metal powders (e.g., titanium, aluminum, stainless steel) within tight tolerances (typically 15–150 µm)
- Ensure consistent coating thickness in thermal spray and plating applications
- Remove oxides, debris, or satellite particles that compromise part strength in 3D-printed components
- Improve safety by isolating fine hazardous dusts during post-processing inspection
Technical note: Compatible with inert gas environments for handling reactive metals like magnesium or zirconium
Research & Development Applications
Scientific laboratories and R&D centers use ultrasonic vibration sieves to conduct material characterization, develop new composites, and validate experimental hypotheses requiring exact particle size control.
- Facilitate nanomaterial research by isolating sub-micron particles for advanced material studies
- Support reproducible results in academic and industrial experiments involving powders or granules
- Enable development of novel drug delivery systems, battery materials, and functional coatings
- Integrate with laser diffraction and microscopy systems for comprehensive particle analysis
Innovation driver: Essential tool in cutting-edge fields like nanotechnology, biomedicine, and energy storage
Cross-Industry Benefits
Beyond specific sectors, ultrasonic sieves offer universal advantages in precision, efficiency, and operational reliability.
- Higher throughput: Up to 95% screening efficiency compared to 50–60% in mechanical sieves
- Reduced downtime: Self-cleaning mesh technology minimizes maintenance and cleaning cycles
- Scalability: Lab-scale data can be translated to industrial ultrasonic systems for seamless scale-up
- Data integration: Modern units include digital controls and reporting for traceability and audit readiness
Smart investment: Long-term cost savings through reduced waste, improved yield, and fewer product recalls
Expert Recommendation: When selecting an ultrasonic sieve for commercial use, prioritize models with adjustable amplitude, frequency control, and interchangeable mesh sizes to accommodate diverse materials. For regulated industries like pharma and food, ensure the equipment is made from FDA-compliant, corrosion-resistant materials (e.g., 316L stainless steel) and supports clean-in-place (CIP) procedures. Always validate sieve performance with standard reference materials during routine QC checks.
| Industry | Primary Application | Particle Size Range | Key Performance Benefit |
|---|---|---|---|
| Pharmaceuticals | API and excipient classification | 20–400 µm | Enhanced drug bioavailability and dosage accuracy |
| Food Processing | Contaminant removal and texture refinement | 50–1000 µm | Improved food safety and sensory quality |
| Chemicals | Powder homogenization and purity control | 10–300 µm | Consistent reaction kinetics and product stability |
| Metal Processing | Metal powder classification for AM and coating | 15–150 µm | Superior mechanical properties in final components |
| R&D / Academia | Material characterization and innovation | 1–500 µm | High reproducibility and experimental precision |
Additional Considerations for Optimal Use
- Mesh Selection: Choose mesh materials (stainless steel, nickel, or polymer) based on chemical compatibility and wear resistance
- Amplitude Adjustment: Fine-tune ultrasonic energy to avoid particle damage in fragile materials like microcapsules or flakes
- Validation Protocols: Regularly calibrate using certified reference powders to maintain measurement accuracy
- Operator Training: Proper handling ensures longevity and consistent performance of transducers and mesh screens
- Integration Capability: Look for models that interface with lab information management systems (LIMS) for automated reporting
How To Choose the Right Lab Ultrasonic Vibration Sieve
Selecting the appropriate ultrasonic vibration sieve for your laboratory is essential for achieving accurate, efficient, and repeatable particle size analysis. These advanced sieving systems use high-frequency vibrations to prevent clogging and improve separation precision—especially for fine, cohesive, or static-prone powders. This guide outlines the key selection criteria to help you make an informed decision based on your lab’s specific application needs in pharmaceuticals, food processing, chemicals, or materials research.
Important Note: Ultrasonic sieves significantly enhance sieving efficiency for fine particles, but proper selection depends on material compatibility, mesh specifications, frequency control, and integration with existing lab workflows. Always verify regulatory and safety standards (e.g., FDA, USP, ISO) when used in quality control or GMP environments.
1. Material of Construction
The material of the sieve frame and mesh directly impacts durability, chemical resistance, and suitability for sensitive applications. Choose based on your sample type and environmental conditions:
- Stainless Steel: The most widely used option in laboratories due to its excellent mechanical strength, corrosion resistance, and compatibility with aggressive solvents and cleaning agents. Ideal for pharmaceutical, food, and chemical applications where hygiene and longevity are critical. Common grades include 304 and 316L for enhanced resistance to chlorides.
- Carbon Steel: A cost-effective alternative suitable for non-corrosive environments and dry, abrasive materials. However, it is prone to rust and not recommended for wet sieving or applications requiring frequent cleaning. Best suited for industrial R&D settings with controlled humidity.
- Ceramic: Offers exceptional hardness and wear resistance, making it ideal for highly abrasive materials such as minerals, ceramics, or metal powders. While brittle, ceramic sieves maintain dimensional stability under extreme mechanical stress and are often used in materials science and metallurgy labs.
- Polymer (e.g., Nylon, Polyethylene): Provides flexibility, chemical inertness, and electrostatic dissipation. Useful for sieving sensitive biological samples or materials that generate static charge. Not suitable for high-temperature or high-pressure applications.
Pro Tip: For regulated industries like pharmaceuticals or food safety, consider customized ultrasonic sieves that meet specific particle size standards (e.g., USP <786>) and include documentation for traceability and validation.
2. Mesh Size and Aperture Specifications
Mesh size determines the particle size range that can be effectively separated. It should be selected based on the nature of your sample and the required resolution:
- Fine Mesh (100–200 microns): Recommended for pharmaceutical powders, APIs (Active Pharmaceutical Ingredients), and nanomaterials. Ensures precise separation of sub-200 µm particles critical for drug efficacy, dissolution rate, and bioavailability testing.
- Medium Mesh (200–400 microns): Suitable for processed food products, granules, and excipients. Balances throughput and precision, helping detect foreign contaminants while maintaining flow efficiency.
- Coarse Mesh (>400 microns): Ideal for bulk chemicals, industrial powders, and coarse aggregates. Prevents clogging and allows rapid processing of large-volume samples with minimal downtime.
Always cross-reference mesh sizes with international standards such as ASTM E11, ISO 3310-1, or BS 410 to ensure consistency and comparability across labs.
3. Ultrasonic Frequency and Amplitude Control
The ultrasonic system’s frequency governs how particles are agitated and dispersed during sieving. Proper frequency selection prevents damage to delicate samples while ensuring effective deblinding:
- Low Frequency (20–30 kHz): Delivers strong vibrational energy suitable for larger, denser, or less fragile particles. Effective for industrial powders and materials with low cohesion. May cause particle degradation if used on brittle or fine substances.
- High Frequency (up to 100 kHz): Provides gentle yet precise particle movement, ideal for fine pharmaceutical powders, proteins, and heat-sensitive compounds. Minimizes particle attrition and ensures uniform dispersion without over-agitation.
Advanced models offer adjustable amplitude and frequency settings, allowing operators to optimize performance for different materials. Look for digital controls with preset programs for reproducibility.
4. Compatibility with Existing Sieve Systems
Seamless integration into your current workflow enhances efficiency and reduces training time:
- Modular Add-On Systems: If your lab already uses standard test sieves (e.g., 200 mm or 300 mm diameter), consider an ultrasonic transducer that attaches directly to existing sieve stacks. This cost-effective upgrade enhances performance without replacing your entire inventory.
- Standalone Units: For labs requiring higher precision or specialized applications (e.g., ultra-fine sieving below 20 µm), invest in a dedicated ultrasonic sieve system with full control over parameters and built-in diagnostics.
- Standardization: Ensure new ultrasonic sieves comply with the same frame dimensions and mesh standards as your current equipment to maintain data integrity and process consistency.
| Criterium | Recommended Option | Best For | Avoid In |
|---|---|---|---|
| Material | Stainless Steel (316L) | Pharma, Food, Chemical Labs | High-chloride environments with carbon steel |
| Mesh Size | 100–200 µm | Fine powders, APIs | Bulk solids with coarse particles |
| Ultrasonic Frequency | 40–60 kHz (adjustable) | Balanced performance | Very fragile or very abrasive materials without tuning |
| Integration | Modular ultrasonic kit | Existing sieve setups | Labs needing full automation |
Expert Tip: Conduct a trial run with your most challenging sample before finalizing your purchase. Many manufacturers offer demo units or application testing services to validate performance under real lab conditions.
Additional Selection Tips
- Look for sieves with anti-static coatings or grounding features when handling powders prone to electrostatic buildup.
- Verify calibration and certification options—some applications require NIST-traceable documentation.
- Consider ease of cleaning and disassembly, especially in multi-product labs to prevent cross-contamination.
- Check warranty, technical support availability, and spare parts (e.g., mesh replacement, transducer lifespan).
- Ensure the control unit is user-friendly with data logging capabilities for audit trails in regulated environments.
Choosing the right ultrasonic vibration sieve involves balancing performance, compatibility, and application-specific demands. By carefully evaluating material, mesh size, frequency control, and integration potential, your lab can achieve superior sieving accuracy, reduce processing time, and maintain compliance with industry standards. When in doubt, consult with technical specialists or request application-specific testing to ensure optimal results.
Frequently Asked Questions About Lab Ultrasonic Vibration Sieves
Cleaning a lab ultrasonic vibration sieve is a critical step in ensuring accurate and contamination-free sieving results. For sieves used with non-staining or non-adhesive materials, routine cleaning can be performed easily using soft-bristled brushes and a mild soapy water solution. Gently scrub the mesh surface to remove any residual particles without damaging the fine wire structure.
For more challenging contaminants or fine powders that adhere strongly to the mesh:
- Ultrasonic Cleaning Bath: Immerse the sieve in a water-based or solvent-based ultrasonic bath. The high-frequency vibrations effectively dislodge stubborn particles from the mesh without physical contact, preserving its integrity.
- Solvent Rinsing: When organic residues are present, use appropriate solvents compatible with both the sieve material (e.g., stainless steel) and the contaminant. Always follow chemical safety guidelines and ensure complete solvent evaporation before reuse.
- Air Drying: After cleaning, allow the sieve to air-dry completely in a dust-free environment. Avoid using heat sources that may warp the frame or damage coatings.
Important: Never use abrasive pads, metal brushes, or harsh chemicals that could scratch the mesh or alter pore size, as this compromises sieving accuracy. Always inspect the mesh under magnification after cleaning to detect any damage or blockages.
Proper maintenance ensures consistent performance, extends equipment life, and maintains the precision of particle size analysis. A comprehensive maintenance routine should include the following steps:
- Inspect Ultrasonic Components: Regularly check the transducer and generator for signs of wear, overheating, or loose connections. Ensure the generator displays stable frequency output and that the transducer is securely attached to the sieve base.
- Examine Sieve Integrity: Look for tears, warping, or deformation in the mesh and frame. Even minor damage can lead to inaccurate results and should prompt immediate replacement.
- Post-Use Cleaning: After each use, remove all sample material and clean the sieve thoroughly to prevent cross-contamination and buildup that could dampen vibrations.
- Dust and Debris Control: Keep the entire system—especially the transducer interface and vibration platform—free of dust, moisture, and chemical residues that may interfere with signal transmission or cause corrosion.
- Frequency Calibration: Periodically verify and adjust the ultrasonic frequency to match the material being sieved. Optimal frequency settings improve dispersion and reduce agglomeration, enhancing sieving efficiency.
- Environmental Protection: Store the sieve in a dry, temperature-controlled area. Avoid exposure to corrosive chemicals, high humidity, or extreme temperatures that can degrade materials over time.
Keeping a maintenance log helps track usage, cleaning cycles, and component replacements, supporting quality control and compliance with laboratory standards.
The service life of a lab ultrasonic vibration sieve varies significantly based on construction materials, usage frequency, sample types, and adherence to maintenance protocols. With proper care, different sieve materials offer the following expected lifespans:
| Material Type | Average Lifespan | Key Factors Influencing Durability |
|---|---|---|
| Stainless Steel | 2–5 years | High resistance to corrosion and wear; ideal for most lab environments. Longevity increases with regular cleaning and avoidance of chloride-based contaminants. |
| Carbon Steel | 1–3 years | More cost-effective but prone to rust if exposed to moisture or corrosive substances. Requires diligent drying and protective storage. |
| Ceramic | 3–10 years | Exceptional resistance to abrasion and chemical attack. Best suited for aggressive or high-wear applications, though more fragile mechanically. |
Additional factors such as ultrasonic duty cycle, frequency intensity, and mechanical stress during handling also impact longevity. Routine inspection and proactive replacement of worn components help maximize operational efficiency and data reliability.
Correct installation is essential for optimal performance and safety. Follow these detailed steps for proper setup:
- Prepare the Workspace: Choose a clean, dry, level surface free from vibrations and electromagnetic interference. Ensure adequate ventilation and access to a grounded electrical outlet.
- Mount the Generator: Securely place the ultrasonic generator on a stable surface near the sieve station. Connect it to a power source and verify that the display powers on without error codes.
- Attach the Transducer: Align and firmly fix the ultrasonic transducer to the base of the sieve. Use the provided hardware and ensure tight coupling to maximize energy transfer. Rubber suction pads or vibration-damping feet should be placed beneath the sieve platform to minimize external movement.
- Connect Cabling: Link the transducer to the generator using the designated cable. Route wires safely away from foot traffic and potential moisture exposure. Inspect cables for fraying or damage before each use.
- Align the Sieve: Position the sieve so that the mesh is parallel to the transducer surface. Misalignment can reduce vibration efficiency and lead to uneven sieving.
- Power and Calibrate: Turn on the system and gradually increase the ultrasonic frequency to the recommended level for your sample type. Use calibration standards or test powders to confirm effective particle dispersion and throughput.
Always refer to the manufacturer’s manual for model-specific instructions. After installation, perform a trial run with a known sample to validate performance before conducting critical analyses.








浙公网安备
33010002000092号
浙B2-20120091-4
Comments
No comments yet. Why don't you start the discussion?