Types of Propane Magnetic Gas Level Indicators
A propane magnetic gas level indicator is a critical device used to monitor the amount of liquid propane in storage tanks, ensuring safe operation, efficient inventory management, and preventing overfilling or depletion. These indicators vary significantly in design, mechanism, and application suitability. Choosing the right type depends on factors such as operating environment, required accuracy, pressure conditions, and whether continuous monitoring or simple level alerts are needed.
Floating Ball Type
Utilizes a buoyant float that rises and falls with the liquid propane level. The float's position is magnetically coupled to an external indicator, providing a real-time visual readout.
Advantages
- Simple, reliable mechanical design
- No external power required
- Cost-effective for basic monitoring
- Good visibility under normal conditions
Limitations
- Limited accuracy in turbulent or rapidly changing levels
- May stick or jam due to debris or ice formation
- Not ideal for high-precision applications
Best for: Residential tanks, small commercial setups, general-purpose monitoring
Bi-Color Ball Indicator
Features a series of magnetic balls that rotate to display different colors (typically red/green or red/white) based on whether they are submerged in liquid or exposed to vapor.
Advantages
- Clear visual distinction between liquid and gas phases
- Highly visible from a distance
- Durable in harsh environments
- Excellent for quick status checks
Limitations
- Less precise for exact level measurement
- Color visibility may degrade over time
- Requires proper lighting for optimal reading
Best for: Industrial storage, outdoor tanks, safety-critical applications
Servo Type
Employs a motor-driven servo mechanism with a weighted float to precisely measure liquid level. The system automatically adjusts the float position and converts it into analog or digital output signals.
Advantages
- High accuracy and repeatability
- Capable of measuring interface levels (liquid/gas)
- Supports remote monitoring and integration
- Ideal for custody transfer and inventory control
Limitations
- Higher cost and complexity
- Requires regular maintenance
- Potential for mechanical failure
Best for: Large-scale industrial tanks, refineries, automated systems
Magnetic Level Gauge
Uses a float with an internal magnet that moves with the liquid level. An external indicator with magnetically coupled flags or balls displays the level without direct contact.
Advantages
- Highly accurate and reliable
- Sealed system prevents leaks
- Suitable for high-pressure and high-temperature applications
- Long service life with minimal maintenance
Limitations
- More expensive than basic float types
- Requires proper alignment during installation
- External indicator can be damaged if impacted
Best for: High-pressure propane tanks, chemical processing, hazardous environments
Switch Type
Uses a magnetic float that activates a reed switch at predetermined levels (e.g., high, low, or alarm points). It functions as a level sensor rather than a continuous gauge.
Advantages
- Provides automated alerts and control
- Simple integration with control systems
- Reliable for set-point detection
- Low power consumption
Limitations
- Does not provide continuous level data
- Limited to discrete level points
- Switches may degrade over time
Best for: Automatic refill systems, safety interlocks, alarm triggers
Rope Type (Capacitance or Resistance-Based)
Features a flexible sensing rope with electrodes that measure changes in electrical resistance or capacitance as the liquid level changes along its length.
Advantages
- Can measure over long vertical distances
- Suitable for deep or irregularly shaped tanks
- Provides continuous level data
- Resistant to pressure and temperature extremes
Limitations
- Susceptible to coating or fouling in dirty environments
- Requires calibration for specific fluids
- More complex installation and wiring
Best for: Deep storage tanks, cryogenic applications, extreme environments
Hydrostatic Type
Measures the pressure exerted by the liquid column at the bottom of the tank. Based on Pascal’s Law, this pressure is directly proportional to the liquid height and density.
Advantages
- No moving parts—high reliability
- Continuous and accurate measurement
- Well-suited for sealed or pressurized tanks
- Easy to integrate with digital systems
Limitations
- Accuracy affected by temperature and density changes
- Requires knowledge of fluid specific gravity
- Sensor can clog or corrode over time
Best for: Pressurized tanks, automated monitoring, process control systems
Vibration Fork
Uses a piezoelectrically driven fork that vibrates at a specific frequency. When the fork contacts liquid, the frequency changes, triggering a switch or signal.
Advantages
- Highly reliable point-level detection
- Unaffected by foam, coating, or turbulence
- Low maintenance and long lifespan
- Compact and easy to install
Limitations
- Only suitable for point-level (not continuous) measurement
- Limited to specific mounting positions
- May require recalibration for different media
Best for: Overfill protection, low-level alarms, safety systems
| Type | Measurement Type | Accuracy | Power Required | Best Application |
|---|---|---|---|---|
| Floating Ball | Continuous | Moderate | No | Residential & small commercial tanks |
| Bi-Color Ball | Visual Continuous | Good | No | Industrial storage, safety monitoring |
| Servo Type | High-Precision Continuous | Excellent | Yes | Custody transfer, refineries |
| Magnetic Level Gauge | Continuous | Very Good | No | High-pressure systems, hazardous areas |
| Switch Type | Point Level | Good (for set points) | Yes | Automated controls, alarms |
| Rope Type | Continuous | Good to Very Good | Yes | Deep tanks, extreme conditions |
| Hydrostatic | Continuous | Very Good | Yes | Pressurized tanks, process control |
| Vibration Fork | Point Level | Excellent (for detection) | Yes | Safety systems, overfill prevention |
Expert Tip: For critical applications like overfill prevention or custody transfer, consider combining multiple technologies (e.g., magnetic gauge with vibration fork switch) to enhance reliability and safety. Always ensure compatibility with propane’s chemical properties and operating pressures.
What Makes a Propane Magnetic Gas Level Indicator Durable?
A propane magnetic gas level indicator is a critical safety and operational device used in residential, commercial, and industrial applications. Its durability ensures reliable performance over time, even under demanding conditions. Several engineering and material factors contribute to the long-term strength and resilience of a tank liquid level gauge. Understanding these elements helps users select high-quality indicators that minimize maintenance and maximize lifespan.
High-Strength Stainless Steel Construction
The core structure of a magnetic level indicator is typically constructed from high-strength stainless steel—a corrosion-resistant alloy containing chromium (usually at least 10.5%). This composition forms a passive oxide layer on the surface, protecting the metal from rust, pitting, and chemical degradation. Unlike carbon steel, stainless steel maintains its integrity when exposed to moisture, salt, and aggressive environments common in outdoor or industrial propane storage setups. This resistance significantly extends the service life of the gauge and reduces the need for frequent replacements.
Durable Float Materials for Long-Term Accuracy
The float is a vital component that moves with the liquid level inside the tank and interacts magnetically with the external indicator. To ensure longevity and consistent performance, floats are manufactured from robust materials such as:
These materials prevent cracking, warping, or degradation over time, ensuring the float remains buoyant and responsive, which directly impacts the accuracy and reliability of level readings.
High-Strength Magnetic Coupling System
The magnetic coupling mechanism allows the internal float’s movement to be transmitted through a sealed chamber to an external visual indicator without any physical penetration of the tank wall. High-performance neodymium or samarium-cobalt magnets are often used due to their strong magnetic fields. Even in low-liquid scenarios or when minor buildup occurs on the chamber walls, a powerful magnetic coupling ensures uninterrupted signal transmission. This design eliminates leakage risks while maintaining precise level monitoring, even in tanks with thick walls or insulation layers.
Resistance to Harsh and Corrosive Environments
Propane level gauges are frequently deployed in environments where they face exposure to rain, snow, salt spray, industrial fumes, and cleaning chemicals. To combat this, manufacturers use corrosion-resistant materials such as:
- Brass level gauges: Known for excellent machinability and corrosion resistance, especially in marine or humid climates.
- Epoxy-coated housings: Provide an additional barrier against rust and chemical attack.
- Sealed enclosures: Prevent ingress of moisture and contaminants.
These features make the gauge suitable for use in refineries, agricultural operations, and remote fueling stations where environmental stressors are common.
Pressure and Temperature Resistance
Durability isn’t just about physical toughness—it also includes the ability to function reliably under extreme operating conditions. Most propane magnetic level indicators are rated for:
| Operating Parameter | Typical Range | Material Consideration |
|---|---|---|
| Pressure Rating | Up to 250 PSI (varies by model) | Stainless steel or reinforced brass housings |
| Temperature Range | -40°F to 250°F (-40°C to 121°C) | Thermally stable polymers and metals |
| Fluid Compatibility | Propane, butane, LPG, and similar hydrocarbons | Inert materials like PTFE seals and polypropylene floats |
This wide operational envelope ensures the gauge remains functional during seasonal temperature swings, pressurization cycles, and emergency venting scenarios, enhancing both safety and system reliability.
Robust Sealing Mechanisms
Internal components must be protected from moisture, dust, and chemical vapors that could impair magnetic function or cause internal corrosion. High-quality level indicators use multi-point sealing systems, including:
- O-rings made from FKM (Viton®): Resistant to high temperatures and hydrocarbon fuels.
- Gland seals: Prevent axial movement and maintain compression over time.
- Hermetic welding: Used in premium models to create leak-proof joints between chambers.
These seals ensure that the magnetic chamber remains dry and contamination-free, preserving long-term accuracy and preventing premature failure.
External Protective Features
Beyond internal design, external protection plays a key role in durability. Many gauges come equipped with:
Protective Covers
Transparent polycarbonate or acrylic shields guard the indicator window from UV degradation, scratches, and impact damage while allowing clear visibility.
Impact Guards
Reinforced metal cages or bumpers protect the gauge body from accidental collisions during transport or servicing.
Weatherproof Enclosures
IP65-rated housings prevent water and dust ingress, making them ideal for outdoor installations.
Thermal Shields
Reflective or insulated covers reduce heat absorption in direct sunlight, preventing false readings due to vapor expansion.
Important: Always verify that your propane magnetic level indicator meets industry standards such as ASME, API, or ANSI for pressure vessel compliance. Using non-certified or poorly constructed gauges can lead to inaccurate readings, leaks, or catastrophic failures. Regular inspection and proper installation are essential to maintaining both safety and durability.
How to Use a Propane Magnetic Gas Level Indicator
A propane magnetic gas level indicator is a reliable and efficient tool for monitoring the liquid level inside propane tanks. Unlike traditional dipsticks or manual estimation methods, magnetic level gauges offer continuous, real-time visibility into fuel levels—critical for safety, operational efficiency, and preventing unexpected outages. Proper use involves correct installation, calibration, routine inspection, and consistent monitoring.
Installation Best Practices
Proper installation is the foundation of accurate readings. The magnetic level gauge must be securely mounted on the propane storage tank in a vertical orientation to allow unimpeded float movement from the bottom to the top of the tank.
- Ensure the gauge is perfectly aligned and straight—any tilt can restrict float travel and cause false readings
- Verify that the float moves freely within the chamber before finalizing installation
- Use appropriate seals and gaskets to prevent gas leakage and contamination from moisture or debris
- Follow manufacturer guidelines for mounting location, typically on the side or top of the tank where vibration and external impacts are minimized
Key Tip: Install the gauge in a location with clear visibility for easy reading during routine checks.
Calibration for Accuracy
While most magnetic level indicators come pre-calibrated, field adjustments may be necessary depending on tank size, shape, and operating conditions.
- Match the gauge scale to your tank’s capacity (e.g., 20 lb, 100 lb, or 500-gallon tanks)
- Adjust the indicator dial so that "Full" aligns with the maximum liquid level when the tank is completely filled
- Account for ambient temperature and pressure variations—propane expands and contracts significantly with temperature changes
- Re-calibrate after any maintenance, replacement, or if the tank has been emptied and refilled
Critical Note: Always calibrate at standard temperature (70°F / 21°C) for consistency. Extreme cold or heat can affect liquid density and float response.
Floating Ball Inspection & Maintenance
The magnetic float (or floating ball) is the core sensing component. It rises and falls with the liquid propane level, magnetically coupling with the external indicator needle.
- Ensure the float is made of a corrosion-resistant, propane-compatible material such as stainless steel or specialized polymer alloys
- Confirm buoyancy: the float must be precisely balanced—too dense and it sinks; too light and it doesn't submerge properly
- Inspect regularly for cracks, pitting, or warping that could trap gas or affect floatation
- Clean the float and guide tube periodically to remove residue, rust, or sludge buildup that can impede movement
- Test functionality by gently tapping the gauge and observing smooth needle movement
Pro Insight: A sluggish or jittery indicator needle often signals float binding or contamination—address immediately to avoid inaccurate readings.
Real-Time Monitoring & Verification
One of the key advantages of magnetic level gauges is their ability to provide continuous, real-time monitoring without requiring tank entry or shutdown.
- Check the gauge daily in high-usage environments (e.g., commercial kitchens, industrial sites)
- Record readings over time to identify usage patterns and anticipate refill needs
- Cross-verify with alternative methods such as weighing the tank or using a dipstick during scheduled maintenance
- Look for sudden drops in level, which may indicate leaks or excessive venting
- Ensure the external indicator is protected from weather, UV exposure, and physical damage
Safety Reminder: Never rely solely on the gauge during critical operations—combine visual inspection with other verification techniques.
Expert Recommendation: For optimal performance, pair your magnetic level indicator with a protective shroud or cover to shield it from environmental wear. Schedule quarterly inspections that include float removal, cleaning, and re-calibration. Training personnel on proper reading techniques and warning signs of failure (e.g., stuck needle, fogged housing) enhances system reliability and safety.
| Maintenance Task | Frequency | Key Action | Potential Issue Prevented |
|---|---|---|---|
| Visual Inspection | Daily | Check for needle movement, cracks, or fogging | Early detection of leaks or float failure |
| Float Function Test | Weekly | Gently tap gauge to confirm smooth response | Binding or stuck float |
| Cleaning & Lubrication | Quarterly | Remove float, clean tube, inspect seals | Sludge buildup, inaccurate readings |
| Re-calibration | Biannually or after refills | Align indicator with known full/empty levels | Drift due to temperature or mechanical stress |
Additional Best Practices
- Environmental Protection: Use weather-resistant housings in outdoor installations to prevent moisture ingress and UV degradation
- Temperature Compensation: Consider gauges with built-in temperature compensation for regions with extreme climate fluctuations
- Compatibility Check: Verify that the float material is compatible with propane and any additives or odorants in the fuel
- Fail-Safe Design: Choose models with redundant indicators or dual-scale readouts (percentage and gallons) for added reliability
- Regulatory Compliance: Ensure the gauge meets DOT, ASME, or other applicable safety standards for pressurized containers
How to Choose a Propane Magnetic Gas Level Indicator: A Comprehensive Guide for Industrial Buyers
Selecting the right propane magnetic gas level indicator is a critical decision for industrial and commercial operations that rely on safe, accurate, and reliable fuel monitoring. These gauges provide real-time visibility into propane tank levels without requiring invasive measurements, minimizing downtime and enhancing safety. This guide outlines the key technical and operational considerations businesses should evaluate when purchasing a magnetic level indicator, ensuring compatibility, durability, and precision under demanding conditions.
Safety Notice: Propane is a flammable gas under pressure. Always ensure that any level gauge used is certified for use with LPG (liquefied petroleum gas) systems and complies with relevant safety standards such as ASME, API, or ANSI. Improper equipment selection can lead to leaks, inaccurate readings, or catastrophic failure.
Tank Material Compatibility and Safety
The material composition of both the propane tank and the magnetic level gauge must be fully compatible to prevent corrosion, galvanic reactions, and static discharge risks. Stainless steel tanks require gauges constructed from equally corrosion-resistant materials such as 304 or 316 stainless steel. Avoid using dissimilar metals that can create electrochemical reactions in humid or outdoor environments.
Crucially, the gauge must be designed to prevent static electricity buildup, which could ignite propane vapors. Look for models with grounded housings, non-sparking components, and certifications for use in hazardous (Class I, Division 2) environments. For example, if your tank is made of carbon steel or aluminum, ensure the gauge’s wetted parts are compatible and sealed against moisture ingress.
Accuracy and Reliability Under Operational Stress
Precision in level measurement depends on two primary factors: float design and magnetic coupling strength. A high-quality float should be buoyant, chemically inert, and sized appropriately for propane’s specific gravity (~0.51). Stronger magnetic coupling between the float and the indicator ensures consistent transmission of level data through the chamber wall, minimizing lag or dropouts.
In dynamic environments where tanks experience vibration, agitation, or rapid filling/emptying cycles, standard gauges may produce fluctuating or inaccurate readings. In such cases, select a model with damping features—such as internal baffles or weighted floats—that reduce turbulence effects. Some advanced indicators include dual floats or guided float systems for enhanced stability and repeatability.
Pressure and Temperature Ratings
Propane tanks operate under significant pressure (up to 250 psi at 70°F, increasing with temperature), so the magnetic level gauge must exceed the tank’s maximum allowable working pressure (MAWP). Always choose a gauge rated at least 1.5 times the system’s operating pressure for safety margin.
Similarly, verify that the gauge can withstand both ambient and internal temperature extremes. Standard operating ranges are typically -40°F to 250°F (-40°C to 121°C), but arctic or desert installations may require extended ranges. Pay close attention to seal materials—Viton, EPDM, or Kalrez O-rings—are essential for maintaining integrity under thermal cycling and chemical exposure.
Measurement Range and Customization Options
The gauge must match the vertical height of the tank to provide full-scale level monitoring from near-empty to near-full. Standard magnetic level indicators are available in fixed lengths, but many manufacturers offer custom configurations to fit non-standard tank dimensions.
For optimal accuracy, ensure the measurement scale covers the entire useful volume of the tank, including allowances for expansion space (typically 10–20% headspace). Look for gauges with clearly marked increments (e.g., 10%, 25%, 50%, 75%, 90%) and optional digital readouts or remote transmission capabilities for integration with SCADA or monitoring systems.
Float Design and Application-Specific Logic
Choosing the correct float type is crucial for accurate and long-term performance. While the original text references methane and liquid metals—applications outside typical propane use—the principles apply:
- Spherical or cylindrical floats: Ideal for clean, non-viscous liquids like propane. They offer smooth movement and minimal sticking.
- Beaded chain floats: Better suited for viscous media or sludge-prone environments—not typical for propane but useful in mixed hydrocarbon applications.
- Guided or rail-mounted floats: Prevent tilting or jamming in tall or narrow chambers, improving accuracy and longevity.
The "error margin" refers to the maximum deviation between the actual liquid level and the indicated position. High-quality magnetic gauges typically maintain an accuracy within ±1/8 inch (±3 mm). Opt for low-error models, especially when precise inventory tracking or automated refill systems are in place.
Mounting Orientation and Installation Flexibility
Magnetic level gauges are most commonly installed vertically alongside the tank, but horizontal mounting options exist for certain tank shapes (e.g., spherical or horizontal cylindrical vessels). Ensure the gauge is compatible with your tank’s nozzle orientation and connection type (e.g., NPT, flanged, or sanitary fittings).
Installation should not interfere with access hatches, valves, or structural supports. Consider gauges with swivel joints or adjustable brackets for easier alignment. Remote-mounted indicators are also available for hard-to-reach locations, using magnetic followers connected via flexible shafts.
Operational Environment and Durability
Beyond internal tank conditions, evaluate the external environment where the gauge will be installed. Outdoor units must resist UV degradation, rain, snow, and temperature swings. Look for IP65 or higher ingress protection ratings to ensure dust and water resistance.
In corrosive atmospheres (e.g., coastal areas, chemical plants), opt for fully encapsulated housings or polymer-coated components. For extreme cold, consider heated or insulated gauge models to prevent ice buildup or float freezing. In high-traffic areas, protective cages or guards can prevent accidental damage.
| Selection Criteria | Recommended Specifications | Common Mistakes to Avoid | Verification Tips |
|---|---|---|---|
| Tank Compatibility | Stainless steel (304/316), non-sparking, LPG-rated | Mixing incompatible metals; ignoring static grounding | Check material compatibility charts; verify ATEX/IECEx certification |
| Accuracy & Reliability | ±3 mm error margin; damping for agitated tanks | Using standard gauges in high-vibration settings | Test response time; inspect magnetic follower strength |
| Pressure/Temperature | 300+ psi rating; -40°F to 250°F range | Undersizing pressure rating; ignoring thermal expansion | Cross-reference with tank MAWP; validate seal material |
| Measurement Range | Customizable to tank height; clear scale markings | Choosing too short a range; poor visibility | Measure tank height; request sample scale layout |
| Float Type | Spherical or guided float; specific gravity matched | Using viscous-media floats for propane | Confirm float SG (0.45–0.55) for propane |
| Environmental Protection | IP65+ rating; UV-resistant housing; optional heater | Installing unshielded gauges outdoors | Inspect housing integrity; verify NEMA rating |
Expert Tip: Before finalizing your purchase, request a sample unit or installation mockup to verify fit, readability, and integration with existing systems. Many suppliers offer engineering support to customize gauges for unique tank configurations or regulatory requirements.
Additional Considerations for Long-Term Performance
- Maintenance Access: Choose a gauge with easy access to the float chamber for cleaning or inspection without full disassembly.
- Regulatory Compliance: Ensure the gauge meets local and international codes (e.g., ASME Section VIII, PED, CRN).
- Remote Monitoring: Consider models with integrated transmitters (4–20 mA, HART, or wireless) for centralized fuel management.
- Warranty and Support: Opt for manufacturers offering multi-year warranties and technical support for troubleshooting.
Investing in a high-quality propane magnetic level indicator enhances safety, reduces operational risks, and improves inventory control. By carefully evaluating tank compatibility, environmental conditions, accuracy needs, and installation logistics, enterprises can select a reliable solution that delivers years of trouble-free service. When in doubt, consult with a process instrumentation specialist to ensure your selection meets all technical and safety requirements.
Frequently Asked Questions About Magnetic Level Gauges
Magnetic level gauges are highly versatile and function reliably in a wide range of industrial and commercial environments. However, their performance can be affected under extreme conditions such as:
- Extreme Temperatures: Very high or low temperatures may impact the float’s buoyancy or the integrity of seals and materials.
- High Pressure: While many models are built for pressurized tanks, exceeding the specified pressure rating can lead to mechanical failure.
- Strong Electromagnetic Interference: Although rare, intense magnetic fields nearby can interfere with the indicator mechanism.
- Vibrational Stress: Excessive vibration from machinery may cause misalignment or wear over time.
To ensure reliable operation, always select a gauge rated for your specific environmental conditions and consider protective housings or isolation mounts when necessary.
Inaccurate readings in magnetic level gauges typically stem from mechanical, material, or environmental issues. Follow these troubleshooting steps:
- Inspect the Float: Check for damage, buildup, or leakage. A compromised float will not rise or fall correctly with the liquid level.
- Verify Material Compatibility: Ensure the float and chamber materials are chemically compatible with the process fluid. Incompatible materials can degrade or absorb liquid, altering buoyancy.
- Check for Obstructions: Debris or scale buildup inside the chamber can restrict float movement, leading to false readings.
- Confirm Proper Installation: Misalignment or improper mounting can hinder float travel and magnetic coupling.
- Calibrate if Necessary: After resolving physical issues, recalibrate the indicator to match actual fluid levels.
For turbulent or aerated liquids, consider installing a stilling well or using high-density floats to improve stability and accuracy. Note: Acoustic or ultrasonic gauges (mentioned in context) are more sensitive to turbulence than magnetic types, which generally perform better in such conditions.
With proper selection, installation, and maintenance, magnetic level gauges offer a long service life—typically between 10 to 15 years. Key factors influencing longevity include:
- Material Quality: Gauges constructed from stainless steel, Hastelloy, or other corrosion-resistant alloys last longer in aggressive environments.
- Float Design: Robust, sealed floats made from appropriate materials resist wear and maintain buoyancy over time.
- Operating Conditions: Exposure to extreme temperatures, pressure cycling, or abrasive fluids can shorten lifespan.
- Maintenance Practices: Regular inspection, cleaning, and timely replacement of worn components extend operational life.
Periodic visual checks and preventive maintenance help detect early signs of wear, ensuring continued reliability and minimizing unplanned downtime.
Yes, magnetic level gauges are an excellent choice for measuring levels in corrosive liquids—provided they are constructed from compatible, corrosion-resistant materials. Their key advantages in such applications include:
- Non-Contact Sensing: The magnetic coupling allows the float to operate inside the chamber while the indicator remains outside, eliminating direct exposure to hazardous or corrosive media.
- Material Flexibility: Chambers and floats can be made from materials like 316 stainless steel, PTFE-lined carbon steel, titanium, or specialized alloys to resist chemical attack.
- Sealed Design: Prevents leakage and protects internal components from degradation.
These features make magnetic level gauges ideal for use in chemical processing plants, wastewater treatment facilities, desalination systems, and marine environments where exposure to acids, alkalis, or saltwater is common.
No, magnetic level gauges are specifically designed to measure liquid levels, not gas. However, they are often used in pressurized vessels where both liquid and gas coexist. Here's how they function in such systems:
- Liquid Interface Detection: The float responds to changes in liquid level based on buoyancy, unaffected by the gas phase above it.
- Pressurized Tank Applications: They are commonly used in boilers, separators, and storage tanks where accurate liquid level monitoring is critical despite the presence of vapor or gas.
- Density-Based Operation: Since gases have significantly lower density than liquids, the float remains submerged in the liquid and does not react to gas movement.
While the gauge indirectly helps manage gas-containing systems by monitoring liquid levels, it cannot directly measure gas volume or pressure. For gas level or inventory measurement, alternative technologies such as radar, ultrasonic, or differential pressure transmitters are more appropriate.