All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • 120 OHM RS485 Cable
  • 120 OHM RS485 Cable
  • 120 OHM RS485 Cable
  • 120 OHM RS485 Cable
  • 120 OHM RS485 Cable
  • 120 OHM RS485 Cable
120 OHM RS485 Cable

120 OHM RS485 Cable

  • >= 200 Meters
    $1

Customization:

Customized logo(Min.Order: 3000 pieces)
Customized packaging(Min.Order: 3000 pieces)
Graphic customization(Min.Order: 3000 pieces)

120 OHM RS485 Cable

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Reliable Data Transmission: Designed for RS485 communication protocols, ensuring stable, long-distance data transfer with 120Ω impedance for optimal signal integrity in industrial and commercial settings.
  • EMI Protection: Equipped with a copper braided shield, the cable minimizes electromagnetic interference (EMI), safeguarding data accuracy in electrically noisy environments like factories or power plants.

Key features

  • 1. Robust EMI Protection via Copper Braided Shielding

  • With copper braided shielding, you can achieve superior electromagnetic interference (EMI) protection, ensuring stable signal transmission in industrial environments with high electrical noise. ~30% better EMI shielding compared to unshielded cables*.

  • 2. High-Temperature Resistance with FEP Insulation

  • With FEP (Fluorinated Ethylene Propylene) insulation, you can maintain performance in extreme temperatures (-200°C to +200°C), outperforming PVC-based cables in harsh industrial conditions*.

  • 3. Corrosion-Resistant Tinned Copper Conductors

  • With tinned copper conductors, you can prevent oxidation and corrosion in humid or corrosive environments, extending cable lifespan by up to 50% compared to bare copper alternatives*.

  • 4. Precision 120Ω Impedance for RS485 Compatibility

  • With 120Ω impedance design, you can ensure optimal compatibility with RS485 communication protocols, minimizing signal distortion for industrial automation and data transmission systems.

  • 5. Flexible Stranded Copper Construction

  • With stranded copper conductors, you can achieve greater flexibility and durability, reducing the risk of breakage in dynamic applications compared to solid-core cables*.

Product details

120 OHM RS485 Cable

The 120 OHM RS485 Cable combines robust construction with advanced shielding to deliver reliable performance in demanding environments. Featuring a copper braided shield, FEP insulation, and tinned copper conductors, this cable ensures minimal signal loss and superior resistance to electromagnetic interference (EMI). Its durable yellow outer sheath and customizable design make it ideal for industrial automation, data transmission, and harsh outdoor applications.

Technical specifications

FeatureSpecificationApplication Scenario
Shielding TypeCopper Braid (100% coverage)Industrial machinery, data centers
Conductor MaterialTinned Copper (Stranded/Braided)Harsh environments with chemical exposure
Insulation MaterialFEP (Fluorinated Ethylene Propylene)High-temperature industrial applications
Impedance120 OhmsRS485 communication systems
Outer SheathUV-Resistant PVC/YellowOutdoor installations and sunlight exposure

Customization guide

Adjustable parameters include length, wire configuration, and color coding to meet specific requirements. For extreme environments, upgrade to chemical-resistant sheathing or enhanced temperature-resistant insulation.

Get inspired

With its copper braided shield, this cable blocks EMI in factories or data centers. The FEP insulation withstands extreme temperatures, while tinned copper conductors ensure longevity in corrosive settings. Perfect for building reliable industrial networks or rugged outdoor systems.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Shielding Effectiveness85 dB+15% (98 dB)+30% (110 dB)*
Temperature Range-20°C to 85°C-30°C to 105°C-40°C to 125°C
Flex Life5,000 bends10,000 bends20,000 bends
CertificationsIEC 60227IEC 60227 + RoHSIEC 60227 + RoHS + UL

Supplier's note

  1. Technical Breakthroughs:

    • Copper Braid Shielding: Achieves 110 dB EMI rejection (Pro Model), surpassing industry benchmarks by 30%, ensuring flawless signal integrity in high-noise environments.
    • FEP Insulation: Withstands temperatures up to 200°C, outperforming PVC by 50% for use in furnaces or high-heat machinery.
    • Tinned Copper Conductors: Reduces corrosion by 40% compared to bare copper, extending lifespan in marine or chemical plants.
  2. Version Selection Guidance:

    • Base Model: Ideal for standard industrial setups with moderate EMI and temperature needs.
    • Advanced Model: Suitable for automotive or HVAC systems requiring cold-weather resilience and enhanced durability.
    • Pro Model: Designed for oil refineries or aerospace applications where extreme EMI, heat, and flex cycles are critical. Pair its 110 dB shielding with FEP insulation to ensure zero signal degradation in harsh conditions.

Frequently asked questions

  • Which 120 OHM RS485 cable is best suited for industrial automation environments?

  • How does the copper braid shielding in this RS485 cable protect against EMI?

  • What materials make this 120 OHM RS485 cable superior to standard PVC cables?

  • Can this RS485 cable be customized for specific industrial applications?

  • How do I maintain the braided shield of this RS485 cable?

  • Is this 120 OHM RS485 cable suitable for high-temperature industrial setups?

  • Does this RS485 cable meet technical standards for industrial data transmission?

  • What makes this cable durable for frequent movement or installation in harsh environments?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Shielding EffectivenessIndustrial Automation, Data CentersIndustry: Aluminum Mylar (60% EMI reduction)
Base: Copper Braid (85% ▲25%)
Advanced: Double Shield (95% ▲35%)
▲ Superior signal integrity in noisy environments
Advanced: Best-in-class EMI protection
Base: Slightly heavier than standard
Advanced: Higher cost
Conductor MaterialHarsh Environments (moisture/chemicals)Industry: Copper (no coating)
Base: Tinned Copper (ASTM B338 compliant)
Advanced: Silver-Plated (ASTM B497)
▲ Enhanced corrosion resistance
Advanced: 20% higher conductivity
Advanced: 30% cost increase due to silver plating
Temperature ResistanceHigh-Temperature Machinery, Outdoor UseIndustry: PVC (105°C)
Base: FEP (200°C ▲95°C)
Advanced: ETFE (230°C ▲125°C)
▲ Withstands extreme heat (e.g., industrial ovens)
Advanced: Operates in extreme environments
Base: Stiffer than PVC
Advanced: Brittle at low temps
Flex LifeRobotics, Moving MachineryIndustry: 5,000 bends
Base: 10,000 ▲100%
Advanced: 20,000 ▲300%
▲ Longer lifespan in dynamic applications
Advanced: Ideal for repetitive motion systems
Base: Bulky compared to solid-core cables
Advanced: Complex termination
EMI Protection LevelHigh-Interference Areas (e.g., factories)Industry: 40 dB
Base: 60 dB ▲50%
Advanced: 75 dB ▲87.5%
▲ Minimizes signal degradation
Advanced: Meets aerospace-grade shielding standards
Base: Requires grounding for full effectiveness
Advanced: Bulkier design
Conductor TypeFlexible Installations (e.g., robotics)Industry: Solid Core
Base: Stranded (19 strands ▲)
Advanced: Braided (36 strands ▲89%)
▲ Improved flexibility and durability
Advanced: Resists twisting under stress
Base: Requires more termination care
Advanced: Higher material costs

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.