All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • 33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker
  • 33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker
  • 33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker
  • 33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker
  • 33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker
  • 33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker
33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker

33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker

  • 1 - 49 Sets
    $4,000
  • 50 - 999 Sets
    $3,500
  • >= 1000 Sets
    $3,200

Customization:

Customized logo(Min.Order: 1 pieces)
Customized packaging(Min.Order: 1 pieces)
Graphic customization(Min.Order: 1 pieces)

33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • High-Voltage Circuit Interruption: Designed to safely interrupt and switch high-voltage AC currents (up to 36kV/40.5kV) and high fault currents (31.5kA/25kA) in indoor power systems.
  • SF6 Gas Technology: Utilizes sulfur hexafluoride (SF6) for superior arc quenching and insulation, ensuring reliable performance under extreme electrical stress.

Key features

  • 1. Advanced SF6 Gas Insulation Technology

  • With SF6 gas insulation and arc-quenching technology, ensure reliable operation under high voltage and current loads. ~30% faster arc extinction compared to vacuum circuit breakers*

  • 2. High Breaking Capacity for Severe Fault Protection

  • With a breaking capacity of up to 31.5kA, handle severe fault currents effectively. 20% higher breaking capacity than standard models*

  • 3. Comprehensive Environmental and Safety Certifications

  • With EPR certifications from France and Germany and CE compliance, meet stringent environmental and safety regulations across Europe.

  • 4. Compact Design for Space-Constrained Environments

  • With a compact design optimized for indoor substations, maximize space efficiency in confined environments. Ideal for commercial and industrial applications where floor space is limited.

  • 5. Modular Construction for Easy Maintenance and Upgrades

  • With modular components, easily upgrade or replace parts without full system downtime. 30% faster maintenance compared to non-modular designs*

Product details

33kV 36kV 40.5kV SF6 Gas Circuit Breaker Indoor High and Medium Voltage AC Gas Circuit Breaker

The 33kV-40.5kV SF6 Gas Circuit Breaker is a high-performance indoor solution for medium to high-voltage AC power systems. Engineered with SF6 gas insulation, it ensures reliable arc quenching and minimal maintenance. Certified for European markets (EPR France/Germany, CE), it supports rated currents up to 2500A and breaking capacities of 31.5kA, making it ideal for industrial and utility applications requiring robust fault interruption.


Technical specifications

FeatureSpecificationBenefit
Rated Voltage36kV, 40.5kVSupports medium/high-voltage grid integration
Breaking Capacity31.5kA, 25kAHandles severe fault currents with precision
Rated Current1250A, 2500AAdapts to varying load requirements
Insulation MediumSF6 GasEnsures compact design and superior safety
CertificationsEPR France, EPR Germany, CEMeets stringent EU safety and environmental standards

Customization guide

Adjustable parameters include:

  • Voltage Rating: Choose between 36kV (standard) or 40.5kV (high-performance) for grid compatibility.
  • Breaking Capacity: Opt for 25kA (base) or 31.5kA (enhanced) to match fault current requirements.
  • Rated Current: Select 1250A (low-load) or 2500A (high-load) for optimal energy efficiency.

Get inspired

With its SF6 gas insulation and modular design, this circuit breaker enables seamless integration into substations and industrial plants. For example:

  • Medium-voltage substations benefit from its compact size and high breaking capacity.
  • Urban power grids gain reliability through its EPR-compliant safety features.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Breaking Capacity25kA31.5kA (+26%)31.5kA (Premium)
Rated Current1250A2500A2500A
Rated Voltage36kV36kV40.5kV (+12.5%)
Weight1,200kg1,400kg1,600kg

Supplier's note

  1. Key Technical Breakthroughs:

    • SF6 Gas Insulation: Enables 30% smaller footprint than vacuum alternatives while maintaining arc resistance.
    • 31.5kA Breaking Capacity: Exceeds IEC 62271-100 standards by 15%, ensuring fault resilience in harsh grids.
    • EPR Compliance: Dual certification (France/Germany) simplifies EU market entry.
  2. Version Selection Guidance:

    • Base Model: Ideal for residential substations needing cost-effective 36kV solutions.
    • Advanced Model: Targets industrial plants requiring 2500A current handling for heavy machinery.
    • Pro Model: Designed for utility-scale grids with 40.5kV systems, offering double the lifespan in corrosive environments due to enhanced sealing.

Example Use Case:
"With the Pro Model’s 40.5kV rating and 31.5kA breaking capacity, operators can safely manage high-voltage faults in offshore wind farms, where salt corrosion and extreme temperatures are common."

Frequently asked questions

  • Which SF6 gas circuit breaker model suits indoor high-voltage applications up to 40.5kV?

  • How to maintain an SF6 gas circuit breaker for optimal performance?

  • SF6 vs. vacuum circuit breakers: Which is better for indoor power substations?

  • Can this SF6 circuit breaker be customized for 33kV systems?

  • Is the SF6 gas circuit breaker EPR-certified for European markets?

  • What installation requirements apply to 36kV indoor SF6 circuit breakers?

  • Does the 40.5kV SF6 breaker include safety features for arc flash prevention?

  • Can this breaker operate in humid or dusty industrial settings?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Voltage RatingIndustrial power distribution, substationsIndustry Standard: 36kV (IEC 62271-100)
Our Base: 36kV
Our Advanced: 40.5kV (IEC 62271-100)
▲12% higher voltage handling (40.5kV) for high-power gridsAdvanced requires reinforced infrastructure (▲ cost)
Breaking CapacityHigh fault current environmentsIndustry Standard: 25kA
Our Base: 25kA
Our Advanced: 31.5kA (IEC 62271-100)
▲26% fault current interruption (31.5kA) for critical systemsAdvanced increases unit cost by ~30% (▲ price)
Rated CurrentData centers, commercial buildingsIndustry Standard: 1250A
Our Base: 1250A
Our Advanced: 2500A (IEC 60947-2)
▲100% continuous current capacity (2500A) for heavy loadsRequires larger conductors (▲ space/weight)
CertificationsEuropean marketsIndustry Standard: CE
Our Base: CE
Our Advanced: CE + EPR France/Germany
▲2 certifications for EU compliance (EPR)Longer approval timelines for Advanced (▲ 2–3 months)
Gas TypeIndoor high-voltage installationsIndustry Standard: SF6 or Vacuum
Our Base/Advanced: SF6 (ISO 60296)
SF6 ensures stable arc quenching (▲ reliability vs Vacuum)SF6 has higher environmental impact (▲ emissions)
Environmental ProtectionHarsh outdoor environmentsIndustry Standard: IP54
Our Base: IP54
Our Advanced: IP66 (IEC 60529)
▲22% better sealing (IP66) against dust/waterAdvanced may need frequent pressure checks (▲ maintenance)

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.