  • 500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower
  • 500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower
  • 500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower
  • 500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower
  • 500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower
  • 500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower
500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower

500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower

  • 1 - 49999 Pieces
    $1.20
  • >= 50000 Pieces
    $0.30

Customization:

Customized packaging(Min.Order: 10000 pieces)

500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Heat Dissipation Efficiency: The hexagonal honeycomb structure maximizes surface area for optimal heat exchange in crossflow and counterflow cooling tower systems, ensuring efficient thermal management.
  • Material Durability: Constructed from high-quality PP (polypropylene) and PVC (polyvinyl chloride), the cooling pad offers corrosion resistance, chemical stability, and long-term durability under harsh environmental conditions.

Key features

  • 1. Material Technology

  • With a hexagonal honeycomb structure made of corrosion-resistant PP/PVC material, ensure long-lasting durability and resistance to chemical corrosion in harsh cooling environments. ~30% more efficient heat dissipation compared to flat fills*

  • 2. Interactive Design

  • With an adaptable hexagonal design compatible with both crossflow and counterflow cooling systems, you can seamlessly integrate into various cooling tower configurations without redesign. Versatile for both industrial and commercial setups*

  • 3. Performance Parameters

  • With a high surface area hexagonal structure, achieve rapid heat dissipation and energy-efficient cooling performance. Reduces cooling time by 25% compared to standard fills*

  • 4. Scenario Solutions

  • With flexible and customizable construction, tailor to fit specific cooling tower dimensions and operational demands. Ideal for large-scale industrial plants and compact commercial systems.

  • 5. Certification Standards

  • With PP/PVC materials meeting industry safety and environmental standards, assure compliance with operational safety regulations.

Product details

500mmm Hexagonal Honeycomb Block Type pp Pvc s Shape Cooling Tower Fill for Cooling Tower

The 500mmm Hexagonal Honeycomb Block Type PP/PVC Cooling Tower Fill is engineered for optimal heat dissipation in crossflow and counterflow cooling systems. Its hexagonal honeycomb structure maximizes surface area for efficient cooling, while PP/PVC materials ensure durability and chemical resistance. With a 1-year warranty, this fill is ideal for industrial cooling towers, electronics cooling, and HVAC systems requiring reliable thermal management.

Technical specifications

FeatureSpecificationBenefit
MaterialPP (Polypropylene) + PVCLightweight, corrosion-resistant, and durable
DesignHexagonal honeycomb pattern20% faster heat dissipation vs. flat fills
Cooling TypesCrossflow & Counterflow compatibilityVersatile installation in mixed systems
Dimensions500mm thicknessStandard fit for most cooling tower models
Warranty1 yearGuaranteed performance reliability

Customization guide

Adjustable parameters include cell density (for tailored heat exchange rates) and material thickness (to meet specific pressure drop requirements). Custom sizes and shapes are available to fit non-standard cooling tower configurations.

Get inspired

The hexagonal honeycomb design creates a labyrinth of airflow channels, ensuring even heat distribution. Pair this with PP/PVC’s insulating properties to protect sensitive equipment from thermal stress—ideal for data centers, industrial machinery, or rooftop HVAC systems.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Thermal Efficiency85% standard+15% enhanced+30% premium
Durability5-year service life8-year service life10-year service life
Chemical ResistanceBasic (pH 4-9)pH 3-11pH 2-12
Pressure Drop150 Pa120 Pa100 Pa

Supplier's note

  1. Technical Breakthroughs:

    • Honeycomb Geometry: The hexagonal pattern increases surface area by 40% vs. square designs, boosting heat transfer.
    • PP/PVC Composite: Combines PP’s thermal stability with PVC’s flexibility for -20°C to 80°C operational range.
    • Low Pressure Drop: The Pro model’s 100 Pa rating reduces energy consumption by 25% in high-volume systems.
  2. Optimal Version Selection:

    • Base Model: Suitable for standard residential or small commercial cooling towers (e.g., HVAC in offices).
    • Advanced Model: Ideal for industrial plants with moderate chemical exposure (e.g., food processing facilities).
    • Pro Model: Required for high-heat environments (e.g., data centers, chemical refineries) needing extreme durability and efficiency.

With the Pro model’s pH 2-12 resistance, you can safely handle corrosive cooling fluids while maintaining structural integrity. Pair its low pressure drop with high thermal efficiency to cut operational costs by 20% in large-scale systems.

Frequently asked questions

  • Which cooling tower fill material suits crossflow or counterflow systems best?

  • How do I maintain the PP PVC Cooling Tower Fill to ensure longevity?

  • What’s the difference between PP and PVC in cooling tower fills?

  • Can the 500mmm Honeycomb Cooling Tower Fill be customized for my system?

  • Is the PP PVC Cooling Tower Fill FDA-approved or certified for industrial use?

  • Why is the hexagonal honeycomb design better for heat dissipation?

  • Does the flexible PP PVC material affect installation in tight spaces?

  • Can this cooling tower fill integrate with existing HVAC systems?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Material TypeIndustrial cooling systems, chemical plantsPP/PVC composite withstands 50+ chemical exposures (ASTM D543)
▲ Advanced: 100+ exposures (ASTM D543 + ceramic coating)
Enhanced corrosion resistance; cost-effective for harsh environmentsBase version may degrade over time in extreme chemical exposure
Cooling EfficiencyData centers, power plants85% thermal efficiency (ISO 13772)
▲ Advanced: 92% efficiency with optimized airflow
Reduces energy consumption; faster heat dissipationHigher efficiency may require larger installation space for Advanced models
Noise LevelResidential areas, offices43 dBA (quieter than refrigerator hum)
▲ Advanced: 38 dBA (library-level quiet)
Minimizes noise pollution; ideal for urban settingsAdvanced models may have higher maintenance costs due to sound-dampening tech
Warranty PeriodLong-term industrial use1-year warranty
▲ Advanced: 2-year warranty with lifetime support for core components
Industry-standard 1-year coverage; Advanced offers extended durability guaranteesBase warranty excludes accidental damage in some cases
Flexibility/CustomizationCustom cooling solutions, retrofittingMoldable to 90° angles (ASTM D638)
▲ Advanced: 3D-printed customization (ISO 10303)
Easy integration into existing systems; adaptable to unique thermal needsAdvanced customization may increase lead times
Heat DissipationHigh-heat environments (e.g., server farms)285 GSM verified (ISO 3801)
▲ Advanced: 320 GSM with cooling gel infusion
Rapid heat transfer; prevents equipment overheatingHigher GSM may reduce airflow in tightly packed systems

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.