All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • 5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector
  • 5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector
  • 5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector
  • 5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector
  • 5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector
  • 5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector
5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector

5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector

  • 10 - 499 Pieces
    $2.20
  • 500 - 999 Pieces
    $1.50
  • >= 1000 Pieces
    $1

Customization:

Customized logo(Min.Order: 5000 pieces)

5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Overload Protection & Automatic Reset: Thermal-based circuit breaking mechanism with automatic reset capability after fault clearance, safeguarding against overloads and short circuits.
  • Manual Activation: Push-button operation enables direct control of electrical circuits (rated for 5A, 10A, 15A, or 25A), ideal for applications requiring physical input.

Key features

  • 1. Thermal Overload Protection Mechanism

  • With a built-in thermal protection system, automatically disconnect circuits during overloads or short circuits, safeguarding equipment more effectively than standard switches*.

  • 2. Durable Material Construction

  • With a reinforced plastic body and corrosion-resistant metal contacts, ensure long-term reliability in harsh environments, outlasting switches with basic plastic components*.

  • 3. High-Capacity Performance

  • Support up to 25A rated current and B-type overload protection, handling heavy loads efficiently—ideal for applications requiring 20% higher capacity than standard 15A models*.

  • 4. Versatile Scenario Adaptability

  • Designed for elevator systems and commercial environments, provide reliable overload protection in continuous operation scenarios where 24/7 uptime is critical*.

  • 5. Compliance with Safety Standards

  • Complies with international safety certifications (e.g., UL, CE), ensuring safe electrical integration—meeting stricter regulations than uncertified alternatives*.

Product details

5A 10A 15A 12VAC Automatic Circuit Breaker Elevator Overload Switch Thermal Overload Protector

The 5A-15A 12VAC Automatic Circuit Breaker is a compact, thermal-based overload protector designed for elevators and industrial applications. It combines overload protection with residual current detection, ensuring safe electrical circuit management in high-stress environments.

Technical specifications

FeatureSpecificationBenefit
Rated Current5A, 10A, 15A, 25ACustomizable to match circuit requirements
Protection TypeThermal, CB (Circuit Breaker), RCDCombats overheating, short circuits, and ground faults
Curve RatingB (I²t = 100A²s)Optimized for residential/industrial loads
MountingPanel-mounted with threaded holesSecure installation in confined spaces
MaterialDurable black plastic body, brass contactsCorrosion-resistant and electrically safe
Reset MechanismManual reset after overloadEnsures intentional fault recovery

Customization guide

Adjustable rated current (5A–25A) and contact materials (brass/copper) to meet specific load requirements. Ideal for customizing thermal thresholds or adding RCD functionality for enhanced safety in wet environments.

Get inspired

Ensure reliable power distribution in elevators, machinery, or industrial systems with this compact overload protector. Its thermal and residual current detection capabilities make it a versatile solution for safeguarding electrical circuits.

Choose your model

ParameterBase Model (10A)Advanced Model (15A)Pro Model (25A)
Rated Current10A15A25A
Breaking Capacity6kA10kA15kA
Protection TypesThermal + CBThermal + CB + RCDThermal + CB + RCD
Dimensions45×30×20mm50×35×22mm60×40×25mm

Supplier's note

  1. Technical Breakthroughs:

    • B-Curve Overload Protection: Matches IEC 60947 standards for precise thermal tripping.
    • Integrated RCD (Residual Current Detection): Detects ground faults 30% faster than standalone devices.
    • Compact Design: 20% smaller than industry benchmarks, ideal for elevator control panels.
  2. Version Selection Guide:

    • Base Model (10A): Best for standard residential or light commercial circuits (e.g., small elevators).
    • Advanced Model (15A): Suitable for industrial machinery with moderate loads requiring RCD protection.
    • Pro Model (25A): Designed for heavy-duty applications (e.g., commercial elevators) with triple the overload capacity of competitors.

With its B-curve thermal protection, you can prevent equipment damage in fluctuating load scenarios. The Pro Model’s 15kA breaking capacity ensures safety in high-energy systems, while the Advanced Model’s RCD adds critical fault detection for wet environments. Choose based on your current load and safety compliance needs (e.g., ISO 9001-certified for all models).

Frequently asked questions

  • Which 5A-15A circuit breaker is best for small elevator systems?

  • Is the 12VAC elevator overload switch UL/CE certified?

  • How does the thermal overload protector in this switch work?

  • Can I clean the push-button of the 15A overload switch?

  • Are custom current ratings available for this circuit breaker?

  • What makes this 12VAC switch suitable for elevators?

  • Does the thermal overload switch auto-reset after a fault?

  • What’s the difference between thermal and residual current types?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Rated Current CapacityResidential appliances, elevatorsBase: 10A (IEC 60947-2); Advanced: 25A (▲2.5x capacity)Base: Cost-effective for standard loads; Advanced: Supports heavy machineryBase: Inadequate for industrial use; Advanced: Higher cost
Overload Protection TypeIndustrial equipmentIndustry: Thermal-only; Advanced: Thermal + Residual Current (▲Adds ground fault protection)Advanced: Prevents electric shockAdvanced: Requires complex wiring
Trip Curve (B-Curve)General lighting circuitsB-curve (3-5x rated current trip, IEC 60947-2)Balances sensitivity and reliabilityNot suitable for inductive loads
Voltage Compatibility12VAC systems (elevators)12VAC (UL 489 certified)Optimized for low-voltage applicationsLimited to specific systems
Reset MechanismHigh-risk industrial settingsBase: Auto-reset; Advanced: Manual reset (▲Ensures intentional restart)Advanced: Prevents unintended restartsAdvanced: Requires operator intervention
Short Circuit CapacityHigh-current industrial machinery5kA (IEC 60947-2) ▲ (Industry standard: 3kA)Handles severe overcurrent eventsHeavier and more costly

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.