All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter
  • Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter
  • Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter
  • Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter
  • Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter
  • Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter
Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter

Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter

$1527.77-$7894.16/ Set|1 Set/Sets(Min. Order)

Customization:

Customized logo(Min.Order: 1 pieces)
Customized packaging(Min.Order: 1 pieces)
Graphic customization(Min.Order: 1 pieces)

Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • High-Precision Measurement: The DN200 Coriolis Mass Flowmeter achieves accuracy of ±0.1% to ±0.2%, enabling precise measurement of methanol flow rate and density in real time.
  • Versatile Fluid Handling: Designed for both liquid and gas mediums, the U-shaped sensor ensures reliable performance in corrosive or aggressive environments, supported by its corrosion-resistant stainless steel construction.

Key features

  • 1. Corrosion-Resistant Material Technology

  • With its corrosion-resistant stainless steel U-shaped pipe, ensure long-term durability in aggressive environments. Up to 30% more resistant to corrosion than conventional materials.

  • 2. Precision Performance

  • With industry-leading 0.1%-0.2% accuracy, achieve measurements up to 60% more precise than standard flow meters*. Maintain reliable readings across diverse fluid conditions.

  • 3. Rigorous Certification Standards

  • With SIL 2/3 and CE certifications, meet global safety and compliance requirements for industrial applications. Ensure reliability in critical process control systems.

  • 4. Seamless Interactive Design

  • With real-time digital display and RS485 output, enable intuitive monitoring and seamless integration with SCADA systems for efficient process management.

  • 5. Versatile Scenario Adaptability

  • With a U-shaped design eliminating additional flanges, reduce installation complexity by ~50% compared to traditional models*. Compatible with gas/liquid media and DN10-200 sizing for applications from water treatment to chemical processing.

Product details

Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter

The Accuracy Reaches 0.1% -0.2% Methanol DN200 Coriolis Density Transmitter 01 Accuracy Coriolis Mass Flowmeter is a high-precision industrial flow measurement solution designed for corrosive and non-corrosive liquids and gases. Built with corrosion-resistant materials and featuring SIL/CE certifications, it delivers real-time flow rate and density data via RS485 output, ensuring compliance and efficiency in chemical, oil & gas, and water treatment applications.

Technical specifications

FeatureSpecificationBenefit
Accuracy±0.1% to ±0.2%Ensures precise measurement for critical processes.
MaterialStainless steel (corrosion-resistant)Withstands aggressive fluids like methanol.
Connection TypesThread, FlangeFlexible installation in existing pipelines.
DN SizesDN10–DN200Supports diverse flow rates and pipe systems.
Media CompatibilityGas/LiquidVersatile for industrial applications.
CertificationsSIL, CEMeets global safety and quality standards.
OutputRS485Enables seamless integration with control systems.
Application ScenarioChemical processing, water treatmentIdeal for environments requiring high accuracy and durability.

Customization guide

Adjustable parameters:

  • DN Size: Customize pipe diameter (DN10–DN200) to match specific flow requirements.
  • Material Coating: Enhance corrosion resistance for aggressive media like methanol.
  • Output Protocol: Adapt RS485 settings for compatibility with existing SCADA systems.

Get inspired

With its U-shaped design and SIL-certified precision, this flowmeter ensures reliable operation in harsh environments. Whether monitoring methanol flow in chemical plants or tracking water treatment processes, its 0.1% accuracy minimizes errors and maximizes productivity.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Accuracy±0.2%±0.15% (+25%)±0.1% (+100%)
Pressure Rating40 bar60 bar (+50%)100 bar (+150%)
Temperature Range-20°C to 120°C-20°C to 150°C-20°C to 200°C
Chemical ResistanceStandardEnhanced (+30%)Triple Industry Std.

Supplier's note

  1. Technical Breakthroughs:

    • Precision: The Pro Model’s ±0.1% accuracy exceeds industry benchmarks, enabling precise dosing in pharmaceuticals.
    • Durability: Corrosion-resistant stainless steel ensures longevity in methanol-handling applications.
    • Integration: RS485 output simplifies real-time data logging for Industry 4.0 systems.
  2. Optimal Version Selection:

    • Base Model: Suitable for general industrial use (e.g., water treatment) with standard pressure and temperature ranges.
    • Advanced Model: Ideal for oil & gas applications requiring +25% higher accuracy and 60 bar pressure.
    • Pro Model: Designed for extreme environments (e.g., chemical processing) with triple corrosion resistance and 200°C tolerance.

With the Pro Model’s chemical resistance and high-temperature tolerance, operators can safely handle corrosive fluids like methanol while maintaining precision. Pair this with its RS485 output to automate process control and reduce downtime.

Frequently asked questions

  • Which DN size of Coriolis mass flowmeter is best for high-flow industrial processes?

  • How to maintain a U-shaped Coriolis flowmeter with flange connections?

  • Stainless Steel vs Plastic: Which material suits methanol applications?

  • Can this Coriolis flowmeter be customized for DN200 methanol pipelines?

  • Is the DN200 Coriolis transmitter SIL-certified for hazardous zones?

  • Does the 0.1% accuracy Coriolis meter handle corrosive fluids like methanol?

  • What communication protocols does the DN200 Coriolis flowmeter support?

  • Can the U-shaped flowmeter measure gas and liquid simultaneously?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Coriolis Mass FlowmeterChemical processing, pharmaceuticalsAccuracy: 0.1%-0.2% (ISO 17025) ▲▲
(Industry: 0.5%, Base: 0.2%, Advanced: 0.1%)
SIL2 (IEC 61508) ▲
(Industry: SIL1)
DN10-200 (ISO 7005)
Direct mass flow measurement, no calibration, high precision for critical processesHigher cost, vibration sensitivity, limited to DN200 max
Turbine FlowmeterWater treatment, HVAC systemsAccuracy: ±1% (ISO 5168)
DN15-200 (ISO 7005)
RS485 ▲ (Industry: analog output)
Cost-effective, wide DN range, real-time data via RS485Requires periodic calibration, less accurate for viscous fluids
Ultrasonic FlowmeterClean liquids, custody transferAccuracy: ±0.5% (ISO 17089)
DN25-500 (ISO 7005)
No moving parts ▲
(Industry: mechanical parts)
Non-invasive, no pressure drop, low maintenanceSusceptible to gas bubbles, high cost for large DN
Differential Pressure FlowmeterHVAC, general industryAccuracy: ±2% (ISO 5168)
DN15-200 (ISO 7005)
Simple design, low cost, compatible with harsh mediaInvasive installation, pressure loss, requires calibration
Vortex FlowmeterSteam, gas, liquid distributionAccuracy: ±1.5% (ISO 17089)
DN15-200 (ISO 7005)
Gas/liquid versatility ▲
(Industry: liquid-only)
Rugged, wide media compatibility, no moving partsRequires straight pipe runs, vibration interference
Electromagnetic FlowmeterWater/wastewater treatmentAccuracy: ±0.5% (ISO 17089)
DN10-2000 (ISO 7005)
Full-bore design ▲
(Industry: restricted flow path)
High accuracy, no pressure loss, bidirectional flowIneffective for gases, susceptible to electrical noise

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.