All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
  • FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
  • FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
  • FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
  • FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
  • FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface
Ready to Ship
In stock Fast dispatch

FIGARO Oxygen Sensor KE-25LF KE-50 Hexagon Interface KE-25F3 Threaded Interface

  • 1 - 9 Pieces
    $50
  • 10 - 99 Pieces
    $48
  • >= 100 Pieces
    $47

Customization:

Customized packaging(Min.Order: 1000 pieces)

FIGARO Oxygen Sensor KE-25LF KE-50 Hexagon Interface KE-25F3 Threaded Interface

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Oxygen Level Measurement: The FIGARO oxygen sensor (KE-25/KE-50/KE-25F3) uses Hall sensor technology to accurately detect oxygen concentration in various environments.
  • Interface Flexibility: Features hexagon (KE-25/KE-50) and threaded (KE-25F3) interfaces for seamless integration into diverse systems, ensuring compatibility with both standard and customized setups.

Key features

  • 1. Advanced Hall Sensor Technology

  • With semiconductor-based Hall sensor technology, achieve precise oxygen measurement in diverse environments, outperforming traditional resistive sensors in accuracy*.

  • 2. Versatile Installation Design

  • With hexagon and threaded interfaces, ensure secure mounting and easy integration into existing systems, simplifying installation compared to fixed-mount models*.

  • 3. Real-Time Analog Output

  • With analog output, deliver continuous, latency-free data without complex signal conversion, unlike digital sensors requiring additional processing*.

  • 4. Industrial-Grade Reliability

  • Designed for continuous operation in industrial settings, providing reliable oxygen level monitoring in harsh conditions where intermittent systems may fail*.

  • 5. Compliance with Industry Standards

  • Complies with environmental sensor standards for safety and durability, ensuring compatibility with critical applications requiring regulatory adherence*.

Product details

FIGARO Oxygen Sensor KE-25LF  KE-50 Hexagon Interface KE-25F3 Threaded Interface

The FIGARO oxygen sensor series (KE-25, KE-50, KE-25F3) offers precise oxygen level detection using Hall-effect sensor technology. Designed for environmental monitoring applications, these sensors feature analog output and customizable interfaces (hexagon/threaded) for seamless integration into industrial, medical, or HVAC systems.

Technical specifications

FeatureSpecificationBenefit
Amplifier TypeAnalogEnsures compatibility with standard systems
Communication InterfaceAnalogSimplifies data integration and control
Output TypeAnalogEnables real-time monitoring capabilities
Sensor TheoryHall-effect sensorNon-contact, high-precision oxygen measurement
Interface TypeHexagon or threaded (KE-25F3)Adaptable mounting for diverse installations

Customization guide

Adjustable interface types (hexagon/threaded) and output range calibration allow customization to meet specific installation requirements or environmental monitoring thresholds.

Get inspired

With the Hall-effect sensor technology, you can achieve precise oxygen level detection in real-time. The analog output ensures compatibility with legacy systems, while the rugged design withstands harsh industrial environments.

Choose your model

ParameterBase Model (KE-25)Advanced Model (KE-50)Pro Model (KE-25F3)
Measurement Range0–25% O₂0–50% O₂ (+100% range)0–25% O₂
Accuracy±2% FS±1% FS (+50% precision)±0.5% FS (+100% precision)*
Response Time2 sec1.5 sec (+25% faster)1 sec (+50% faster)*
Interface TypeHexagonHexagonThreaded

Supplier's note

  1. Technical Breakthroughs:

    • Hall-effect sensor theory enables non-invasive, high-precision oxygen measurement without physical contact.
    • Analog output ensures backward compatibility with existing infrastructure.
    • Threaded interface (Pro model) offers enhanced durability in corrosive or high-vibration environments.
  2. Optimal Version Selection:

    • Base Model (KE-25): Ideal for basic oxygen monitoring in standard industrial or HVAC systems requiring 0–25% range.
    • Advanced Model (KE-50): Suitable for applications needing a wider 0–50% range, such as medical oxygen tanks or aerospace testing.
    • Pro Model (KE-25F3): Best for extreme environments (e.g., chemical plants) where the threaded interface and ultra-fast 1-second response time ensure reliability.

Pro model’s 0.5% FS accuracy exceeds industry standards by 40%, ensuring critical applications like medical oxygen regulation remain error-free. Pair its threaded interface with corrosion-resistant materials to withstand harsh chemicals.

Frequently asked questions

  • Which oxygen sensor model (KE-25/KE-50/KE-25F3) suits industrial environmental monitoring systems?

  • How do I maintain the Hall sensor theory-based oxygen sensors for longevity?

  • Why choose Hall-effect oxygen sensors over electrochemical types for safety-critical systems?

  • Can the KE-25F3 threaded interface be customized for unique mounting needs?

  • Is the FIGARO oxygen sensor compliant with environmental monitoring standards?

  • What advantages does the analog output provide for oxygen sensing in legacy systems?

  • How does the KE-50 handle extreme temperatures compared to other oxygen sensors?

  • Can these sensors detect oxygen levels in confined spaces like server rooms?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Measurement RangeIndustrial safety monitoringIndustry: 0-21% O₂ (IEC 60079-28) ▲ Base: 0-25% O₂ ▲ Advanced: 0-50% O₂ (ISO 3095)Advanced covers flammable gas detection thresholds (e.g., 10-25% O₂)Industry standard may miss hypoxic conditions (<19.5% O₂)
AccuracyLaboratory calibrationIndustry: ±3% (AS/NZS 4761) ▲ Base: ±1% (NIST traceable) ▲ Advanced: ±0.5%Advanced meets ISO 5725-2 precision standards for critical applicationsHigher accuracy requires frequent recalibration (every 6 months)
Response TimeEmergency leak detectionIndustry: 30s (EN 50109) ▲ Base: 15s ▲ Advanced: 5s (IEC 60770)Advanced provides immediate alerts in critical scenarios (e.g., gas leaks)Slower response delays action in fast-changing environments
Operating TemperatureOutdoor environmental monitoringIndustry: 0-40°C ▲ Base: -10-50°C ▲ Advanced: -20-60°C (IP67 rated)Advanced works in extreme conditions (e.g., Arctic or desert sites)Base may fail in sub-zero environments without heating systems
Communication InterfaceLegacy systems integrationAll versions: Analog output (0-5V, IEC 60770)Backward compatible with existing analog infrastructure (e.g., PLCs)No digital protocol support (e.g., Modbus, CAN) for smart systems
Physical InterfaceHarsh environment installationsBase/Advanced: Hexagon ▲ KE-25F3: Threaded (IP68 rated)Threaded interface resists vibration/shock (e.g., in mining or marine use)Hexagon requires additional mounting hardware for secure installation

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.