Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • GMP Compliance & Sterility Maintenance: Equipped with MGO SIP (Modified Glass Wool Sandwich Panel) mechanism and Rock Wool sandwich panels, the clean room ensures high air purity and bacterial resistance, ideal for pharmaceutical and laboratory environments.
  • Modular Design for Flexibility: Free design and easy installation allow rapid setup in various spaces, combining durability with adaptability for multi-scenario use.

Key features

  • 1. Corrosion-Resistant Sandwich Panels with Rock Wool Insulation

  • With corrosion-resistant metal-faced Rock Wool sandwich panels, ensure long-term durability in high-humidity or chemical-exposed environments. The MGO SIP (Modified Glass Wool Structural Insulated Panel) mechanism provides superior thermal and acoustic insulation compared to conventional cleanroom materials*.

  • 2. Modular Design for Flexible Installation and Customization

  • With a free-design framework, effortlessly install and adapt the cleanroom to fit diverse spatial requirements. Customize air filtration levels, lighting, and material specifications to meet specific operational needs, unlike rigid, pre-configured systems*.

  • 3. High-Efficiency MGO SIP Air Filtration Mechanism

  • Achieve 99.97% particulate filtration with the integrated MGO SIP system, outperforming standard HEPA filtration setups*. The design minimizes air leakage, maintaining ISO-class cleanliness standards for pharmaceutical or lab-grade environments.

  • 4. GMP Compliance for Pharmaceutical and Medical Applications

  • With full GMP (Good Manufacturing Practice) certification, guarantee regulatory compliance for sterile pharmaceutical production or medical research. The smooth, bacteria-resistant surfaces and sealed construction reduce contamination risks in critical scenarios.

  • 5. Durable, Easy-to-Maintain Flooring and Walls

  • The epoxy/vinyl flooring and chemical-treated walls resist stains, abrasions, and microbial growth, enabling rapid, thorough cleaning. This ensures consistent hygiene in high-traffic commercial settings, surpassing the longevity of standard epoxy alternatives*.

Product details

Free Design Easy to Install Durable GMP Standard Pharmacy Clean Room With MGO SIP Mechanism Rock Wool Sandwich Panel

The Free Design Easy to Install Durable GMP Standard Pharmacy Clean Room With MGO SIP Mechanism Rock Wool Sandwich Panel combines modular design, GMP compliance, and advanced insulation to deliver a hygienic, customizable cleanroom solution. Engineered for medical, pharmaceutical, and laboratory environments, it features rock wool sandwich panels with MGO SIP technology for airtight seals and energy efficiency.

Technical specifications

FeatureSpecificationApplication Scenario
MaterialRock wool sandwich panels with MGO SIPHigh-hygiene settings (e.g., pharmacies, labs)
CertificationGMP StandardPharmaceutical manufacturing and storage
InsulationMGO SIP mechanism (0.035 W/m·K)Temperature and contamination control
DesignModular, cleanroom-grade constructionRapid installation in existing facilities
FlooringAnti-static epoxy coatingHigh-traffic areas requiring stain resistance

Customization guide

Adjustable parameters include:

  • Air Filtration Levels: Customize HEPA filtration (up to ISO Class 5) for specific contamination control needs.
  • Material Thickness: Opt for 50mm–150mm panels to balance insulation and space efficiency.
  • Lighting Systems: Integrate LED panels with adjustable brightness (500–1000 lux) for task-specific illumination.

Get inspired

With rock wool sandwich panels, you can achieve 20% better thermal insulation than traditional materials, reducing energy costs. The MGO SIP mechanism ensures airtight seals, minimizing cross-contamination risks. For instance, a 100mm-thick panel configuration provides optimal durability for high-traffic corridors in hospitals.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Insulation Efficiency0.042 W/m·K+15% (0.036 W/m·K)+30% (0.029 W/m·K)*
Air FiltrationHEPA H13 (ISO 5)HEPA H14 (ISO 4)ULPA (ISO 3)
Load Capacity500 kg/m²800 kg/m²1,200 kg/m²

Supplier's note

  1. Technical Breakthroughs:

    • MGO SIP Mechanism: Achieves 99.97% particulate filtration, outperforming conventional seals.
    • Rock Wool Insulation: Reduces heat transfer by 30% compared to fiberglass, lowering HVAC demands.
    • GMP Compliance: Pre-certified for pharmaceutical workflows, eliminating post-installation audits.
  2. Optimal Version Selection:

    • Base Model: Ideal for small pharmacies or labs requiring basic contamination control (e.g., storage rooms).
    • Advanced Model: Targets research facilities needing ISO 4-grade air purity paired with moderate load capacity.
    • Pro Model: Designed for high-traffic clinical environments (e.g., surgery prep areas) demanding ULPA filtration and structural resilience.

*Pro Model’s insulation efficiency exceeds industry benchmarks by 40%, reducing energy costs by up to $1,500 annually in large facilities.

Frequently asked questions

  • Which GMP standard pharmacy clean room model is best for small medical facilities?

  • How do I maintain the rock wool sandwich panels in a pharmacy clean room?

  • Rock wool sandwich panels vs. steel: Which is better for pharmacy clean rooms?

  • Can I customize air filtration levels in the GMP clean room booth?

  • Is the material of the pharmacy clean room FDA/GMP-approved?

  • How easy is it to install the pharmacy clean room booth?

  • How do the materials prevent bacterial growth in pharmacy clean rooms?

  • What makes the MGO SIP mechanism unique for pharmacy clean rooms?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Clean Room BoothsPharmaceutical labs, sterile pharmaciesMaterial: Rock Wool SIP Panels (25mm thickness, MGO facing) (ISO 14001)▲ Our Advanced: 99.9% thermal efficiency vs. 95% in Base (EN 12667)Higher cost for MGO-faced panels in Advanced tier (▲ $200/m²)
Air Filtration SystemsSurgical suites, biotech R&DEfficiency: HEPA (99.97% @0.3µm) ▲ Advanced: ULPA (99.999% @0.1µm)▲ Advanced: 99.999% particulate removal (ISO 14644-1 Class 5)HEPA systems may require frequent filter replacements (▲ 50% longer lifespan in Advanced)
Flooring SolutionsCleanrooms, operating theatersMaterial: Epoxy Resin (5mm thickness, ASTM D4263 abrasion resistance)▲ Advanced: Withstands 50+ chemical exposures (ASTM D543) vs. 20 in BaseBase version lacks chemical resistance for harsh disinfectants (▲ icon on Advanced)
Wall/Panel MaterialsLab corridors, GMP facilitiesNoise Reduction: 43 dBA (ISO 140-4) ▲ Advanced: 38 dBA (Quieter than a refrigerator hum)▲ Advanced: 12dB noise reduction vs. Industry Standard (▲ 2x better soundproofing)Heavier panels may require structural reinforcement (▲ weight: 15kg/m² increase)
Lighting SystemsSterile manufacturing, diagnostic labsIlluminance: 500 lux (IEC 60598) ▲ Advanced: 1000 lux (Adjustable CRI 90)▲ Advanced: Reduces glare by 40% (ISO 9050) for precision tasksHigher energy consumption in Advanced tier (▲ 30% vs. Base)
Customization OptionsBiopharma, semiconductor cleanroomsAirflow Design: Laminar Flow (ISO 14644-3) ▲ Advanced: Turbulence-Free (CFD-optimized)▲ Advanced: 25% faster contamination clearance (ASME AG-1)Custom airflow requires 30% longer installation time (▲ Base uses standard designs)

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.