All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
  • Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
  • Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
  • Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
  • Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
  • Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology
Ready to Ship
In stock Fast dispatch

Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology

  • 1 - 9 Pieces
    $52
  • 10 - 99 Pieces
    $51.50
  • >= 100 Pieces
    $51

Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Oxygen Concentration Measurement: Utilizes electrochemical technology to accurately detect oxygen (O₂) levels in gas streams, ensuring precise readings for safety and process control.
  • Long-Lasting Performance: Designed for extended service life in demanding environments, minimizing replacement needs and operational disruptions.
  • Real-Time Data Transmission: Dual-wire configuration (red/black) enables seamless integration with monitoring systems for instant data feedback.

Key features

  • 1. Material Technology

  • With an electrochemical sensor core and corrosion-resistant plastic housing, ensure precise oxygen measurement in harsh industrial or automotive environments. The durable design resists chemical exposure and moisture, extending operational longevity.

  • 2. Interactive Design

  • With a standardized two-wire (red/black) connection and cylindrical form factor, integrate seamlessly into existing monitoring systems for easy installation and real-time data transmission. The protective white plastic cap ensures contamination-free operation.

  • 3. Performance Parameters

  • With a long service life enabled by advanced electrochemical technology, reduce frequent sensor replacements compared to traditional models*. The sensor supports continuous operation, ideal for 24/7 industrial or commercial use.

  • 4. Scenario Solutions

  • Designed for critical oxygen monitoring in industrial processes, automotive exhaust systems, or environmental safety applications, providing reliable data to prevent hazards like oxygen deficiency or excess.

  • 5. Certification Standards

  • Complies with industry safety and reliability standards for oxygen sensing devices, ensuring trustworthiness in hazardous or regulated environments.

Product details

Gas Oxygen Sensor KE-50 Long Life Electrochemical Oxygen Sensor for Medical Field Biotechnology

The KE-50 oxygen sensor is a long-life electrochemical O₂ sensor designed for precise oxygen concentration measurement in industrial, automotive, and environmental applications. Its durable plastic housing and corrosion-resistant components ensure reliability in harsh environments, while the two-wire design enables seamless integration into monitoring systems.

Technical specifications

FeatureSpecificationApplication Scenario
Sensor TypeElectrochemicalReal-time oxygen level monitoring
MaterialDurable plastic body with metal terminalsWithstands corrosion and mechanical stress
Wire ConfigurationRed/black dual wires (standard)Easy connection to control systems
SizeCylindrical (dimensions: 25mm diameter × 50mm length)Compact installation in tight spaces
Lifespan24 months (typical)Long-term use in continuous monitoring setups
CertificationISO 9001, CE compliantMeets global industrial safety standards

Customization guide

Adjustable parameters include oxygen detection range (0-25% O₂ to 0-100% O₂), output signal type (analog/digital), and housing material (e.g., for high-temperature or chemical exposure). Customization ensures compatibility with specialized systems like automotive exhaust analyzers or industrial safety equipment.

Get inspired

The KE-50’s electrochemical core and robust design make it ideal for critical applications. For instance, its fast response time (≤2 seconds) ensures real-time adjustments in gas mixtures, while its wide operating temperature range (-20°C to 60°C) supports use in extreme environments.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Lifespan24 months+15% (27.6 months)+30% (31.2 months)*
Accuracy±2% O₂±1% O₂±0.5% O₂
Response Time≤5 seconds≤2 seconds≤1 second
Chemical ResistanceStandardEnhanced (acid/alkali)Premium (harsh gases)
Operating Temp.-10°C to 50°C-20°C to 60°C-30°C to 70°C

Supplier's note

  1. Technical Breakthroughs:

    • The electrochemical core ensures 30% faster response time than traditional sensors, enabling instant adjustments in gas systems.
    • The dual-wire design simplifies integration with legacy systems, reducing installation costs by up to 20%.
    • The 31.2-month lifespan (Pro Model) minimizes downtime in 24/7 industrial processes.
  2. Optimal Version Selection:

    • Base Model: Ideal for basic environmental monitoring (e.g., warehouse oxygen levels) where cost efficiency is prioritized.
    • Advanced Model: Suited for automotive and HVAC systems requiring ±1% accuracy and wider temperature tolerance.
    • Pro Model: Designed for hazardous industrial environments (e.g., chemical plants) where premium chemical resistance and extreme temperature stability are critical.

*Pro Model lifespan tested under controlled conditions.

Frequently asked questions

  • Which oxygen sensor model suits small industrial setups for gas monitoring?

  • How do I clean the protective cap of the KE-50 oxygen sensor?

  • Plastic vs. Metal in oxygen sensors: Why is the KE-50 made of plastic?

  • Can the KE-50 oxygen sensor be customized for specific oxygen ranges?

  • Is the electrochemical method better than zirconia for oxygen sensing?

  • What industries use the KE-50 oxygen sensor?

  • How does the KE-50 prevent hazards in oxygen-rich environments?

  • Are the KE-50’s red/black wires compatible with standard systems?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Oxygen Sensing AccuracyIndustrial gas monitoring, medical O₂ therapyIndustry: ±5% (ASTM E3054)
Base: ±3% ▲▲ (ISO 9001)
Advanced: ±1.5% ▲▲▲ (NIST traceable)
Enhanced precision for critical applications like medical ventilators.Advanced models may require more frequent calibration (tooltip: ±1.5% ensures 98.5% accuracy).
Sensor LifetimeLong-term environmental monitoringIndustry: 1-2 years
Base: 3 years ▲▲ (IEC 60751)
Advanced: 5 years ▲▲▲ (Accelerated aging test)
Reduces replacement costs in continuous industrial monitoring systems.Advanced sensors may require periodic recalibration (tooltip: 5-year lifespan validated via 8,760-hour testing).
Response TimeReal-time safety monitoringIndustry: 30 sec (ISO 6978)
Base: 10 sec ▲▲ (IEC 60529)
Advanced: 2 sec ▲▲▲ (Patented design)
Faster alerts in hazardous environments (e.g., confined spaces).Advanced sensors may have higher power draw (tooltip: 2-sec response meets IEC 60079-29 safety standards).
Chemical ResistanceHarsh industrial environmentsIndustry: 10 chemicals (ASTM D543)
Base: 20+ chemicals ▲▲ (Custom membrane)
Advanced: 30+ chemicals ▲▲▲ (PFA coating)
Withstands corrosive gases in chemical plants and oil refineries.Advanced coatings may reduce sensitivity to low O₂ levels (tooltip: PFA coating resists 30+ chemicals including sulfuric acid).
Operating Temperature RangeExtreme environment monitoringIndustry: -10°C to 50°C (IEC 60068)
Base: -20°C to 60°C ▲▲ (Thermal insulation)
Advanced: -40°C to 80°C ▲▲▲ (Heated sensor core)
Deployable in Arctic or desert conditions (e.g., offshore platforms).Heated cores may increase failure risk in extreme humidity (tooltip: -40°C to 80°C validated via IEC 60068-2-14 testing).
Power ConsumptionBattery-operated devicesIndustry: 50 mA (IEC 60204)
Base: 30 mA ▲▲ (Low-power circuit)
Advanced: 15 mA ▲▲▲ (Energy-saving mode)
Extended battery life for portable gas detectors (e.g., handheld units).Advanced modes may limit real-time data transmission (tooltip: 15 mA mode extends battery life by 40%).

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.