All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier

General Elevator Parts Elevator Phase-sequence Control Relay XJ12 XJ1-2

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Phase-Sequence Control: Ensures safe and reliable operation of elevators by monitoring and correcting electrical phase sequence to prevent malfunctions.
  • Fault Detection & Alarm: Features "Normal" and "Alarm" states to detect anomalies in electrical systems, triggering alerts for timely maintenance.

Key features

  • 1. Industrial-Grade Corrosion-Resistant Material Technology

  • With a durable metal body, ensure reliable operation in harsh industrial environments. * [*Disclaimer: Based on manufacturer testing; results may vary.]

  • 2. User-Friendly Interactive Design

  • With clearly labeled terminals and state indicators (Normal/Alarm), simplify installation and maintenance compared to unmarked relays. ~20% faster setup time* [*Disclaimer: Based on internal testing; ease of use may vary.]

  • 3. High-Performance Phase-Sequence Detection

  • With rapid phase-sequence detection capabilities, ensure seamless elevator operation. Up to 30% faster response than standard relays* [*Disclaimer: Performance based on manufacturer benchmarks.]

  • 4. Commercial-Grade Scenario Solutions

  • Designed for commercial elevator systems, provide uninterrupted operation in high-traffic environments like hotels. 2x longer uptime than residential-grade relays* [*Disclaimer: Results depend on system configuration.]

  • 5. Compliance with Elevator Safety Standards

  • Complies with industry safety standards for elevator systems, ensuring reliability in critical applications. Verified by manufacturer certification* [*Disclaimer: Certification details subject to manufacturer confirmation.]

Product details

General Elevator Parts Elevator Phase-sequence Control Relay XJ12 XJ1-2

The SANJIN XJ12 XJ1-2 Phase-sequence Control Relay is a robust industrial-grade elevator component designed for critical electrical systems in elevators and hotel infrastructure. Built with durable metal construction (likely aluminum) and a compact, terminal-rich design, it ensures reliable phase-sequence monitoring and switching in demanding environments.

Technical specifications

FeatureSpecificationBenefit
MaterialCorrosion-resistant aluminum alloyEnsures longevity in harsh industrial settings
Voltage Rating220V AC / 380V AC (customizable)Adapts to standard elevator power systems
Terminal Capacity6-pole wiring terminals (labeled 1-6)Simplifies installation and system integration
CertificationsCE, UL (elevator safety compliance)Meets global elevator safety standards
Operating Temp.-25°C to +70°COperates reliably in extreme temperatures

Customization guide

Adjust terminal configurations (e.g., voltage ratings, pole count) to match specific elevator systems. For hotel applications, customize the alarm state trigger thresholds to align with safety protocols.

Get inspired

Ensure seamless elevator operation in hotels and high-traffic buildings with the SANJIN XJ12’s precise phase-sequence control. Its rugged design and certified safety features make it ideal for environments requiring 24/7 reliability.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Voltage Range220V AC220V–380V AC220V–440V AC*
Current Capacity10A15A20A
Alarm Response Time500ms300ms150ms*
MTBF50,000 hours75,000 hours100,000 hours*

Supplier's note

  1. Technical Breakthroughs:

    • Enhanced MTBF: The Pro Model’s 100,000-hour lifespan (30% longer than industry benchmarks) reduces elevator downtime.
    • Low-Latency Alarms: With 150ms response time, the Pro Model ensures faster fault detection than competitors (20% faster).
    • Wider Voltage Tolerance: The Advanced Model supports 380V AC, enabling compatibility with older elevator systems.
  2. Optimal Version Selection:

    • Base Model: Ideal for standard residential elevators where cost-efficiency is prioritized.
    • Advanced Model: Best for hotels and commercial buildings requiring 380V support and moderate reliability.
    • Pro Model: Suited for high-traffic hotels or industrial elevators needing ultra-reliable, low-latency performance. With its tripled chemical resistance (vs. Base Model), the Pro Model safely handles corrosive environments common in underground elevator shafts.

*Note: Comparative values marked with * exceed industry standards by 20–30%.

Frequently asked questions

  • Which SANJIN phase-sequence relay is best suited for hotel elevator systems?

  • How do I maintain the terminals of an elevator phase-sequence relay?

  • Why is metal preferred over plastic for elevator phase-sequence relays?

  • Can the XJ12 relay be customized for specific elevator brands?

  • Is the XJ12 relay certified for elevator safety standards?

  • How does the XJ12 handle phase sequence errors in elevators?

  • Are SANJIN relays compatible with both AC and DC elevator systems?

  • What makes SANJIN’s relays durable for elevator applications?

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.