All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
  • Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
  • Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
  • Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
  • Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
  • Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter
Ready to Ship
In stock Fast dispatch

Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter

  • 1 - 99 Units
    $259
  • >= 100 Units
    $189

Customization:

Customized logo(Min.Order: 100 pieces)
Customized packaging(Min.Order: 100 pieces)
Graphic customization(Min.Order: 100 pieces)

Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Ultrasonic Flow Measurement: Measures water flow rate (in m³/h) and velocity (m/s) using non-invasive ultrasonic technology, ensuring precise readings with ±0.2% accuracy.
  • Clamp-On Design: Enables installation without interrupting pipe systems, reducing downtime and simplifying retrofitting in existing infrastructure.
  • RS485 Output: Supports seamless integration with industrial automation systems via digital communication for real-time data monitoring.

Key features

  • 1. Corrosion-Resistant Material Technology

  • With corrosion-resistant stainless steel sensors, you can ensure reliable operation in harsh industrial environments. ~30% more durable than plastic-based sensors*

  • 2. Clear Interactive Design for Real-Time Monitoring

  • With a clear digital display showing real-time flow rate and velocity, you can monitor performance effortlessly, eliminating the need for manual calculations. Up to 50% faster data interpretation compared to analog meters*

  • 3. Precision Performance Parameters

  • With ±0.2% accuracy, you can achieve precise measurements, up to 20% more accurate than conventional flow meters*. This ensures reliable data for critical industrial processes.

  • 4. Clamp-On Installation for Zero Downtime

  • With clamp-on installation, you can retrofit existing systems without interrupting operations, saving ~2 hours of downtime compared to invasive meters*. Ideal for cost-sensitive industrial applications.

  • 5. RS485 Output for Seamless Integration

  • With RS485 output compliant with industrial communication standards, you can integrate seamlessly with existing control systems, ensuring compatibility with 90% of industrial setups*.

Product details

Holykell Clamp on Pipe Line Module Type Ultrasonic Flow Meter

The Holykell Clamp-on Ultrasonic Flow Meter is a versatile, non-invasive solution for precise water flow measurement. Designed for industrial applications, it combines clamp-on technology with ±0.2% accuracy and RS485 output, enabling seamless integration into existing systems without process interruption.

Technical specifications

FeatureSpecificationBenefit
Accuracy±0.2%Ensures high precision in critical applications
Medium CompatibilityWaterOptimized for clean or mildly contaminated water
Output ProtocolRS485Enables real-time data transmission to SCADA systems
Installation TypeClamp-onNo pipe cutting or downtime required
DisplayBacklit digital screenClear visibility in low-light environments
MaterialStainless steel sensors + corrosion-resistant housingDurable for harsh industrial environments

Customization guide

Adjustable parameters include flow range calibration (to match specific water velocity requirements) and output protocol settings (RS485/Modbus compatibility). Customizable mounting brackets and temperature compensation options are available for specialized applications.

Get inspired

With its clamp-on design and RS485 connectivity, this flow meter is ideal for retrofitting water treatment plants, industrial pipelines, or HVAC systems. Its ±0.2% accuracy ensures reliable monitoring of water usage in agriculture, manufacturing, or municipal infrastructure.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Accuracy±0.5%±0.3%±0.2%
Max Flow Range0.1–5 m/s0.1–10 m/s0.1–15 m/s
Temperature Range-10°C to 60°C-20°C to 80°C-30°C to 120°C
CertificationsCECE + ISO 9001CE + ISO 9001 + ATEX

Supplier's note

  1. Technical Breakthroughs:

    • ±0.2% Accuracy: Triple the precision of standard clamp-on meters, enabling compliance with ISO 5167 for regulated industries.
    • Non-Invasive Clamp-on Design: Reduces installation time by 20% compared to inline flow meters, minimizing operational downtime.
    • RS485 + Modbus Compatibility: Simplifies IoT integration, supporting smart factory automation.
  2. Version Selection Guidance:

    • Base Model: Ideal for small-scale water systems (e.g., irrigation) where cost efficiency is prioritized.
    • Advanced Model: Suited for industrial plants requiring durability in fluctuating temperatures (e.g., food processing).
    • Pro Model: Best for high-precision applications (e.g., pharmaceutical or oil & gas) needing ATEX certification for hazardous environments.

With the Pro Model’s ±0.2% accuracy, you can ensure compliance in regulated industries. Pair it with its -30°C to 120°C temperature range to handle extreme conditions, delivering reliable data even in harsh environments. For cost-sensitive projects, the Base Model’s 20% faster installation makes it a practical choice.

Frequently asked questions

  • Which clamp-on ultrasonic flow meter suits water flow measurement in industrial pipelines?

  • How do I maintain the sensors of a clamp-on ultrasonic flow meter for long-term use?

  • Clamp-on vs. Insertion-type flow meters: Which is better for existing pipelines?

  • Can the Holykell ultrasonic flow meter handle corrosive fluids besides water?

  • What customization options does the Holykell flow meter offer for industrial integration?

  • Is the Holykell ultrasonic flow meter certified for industrial accuracy standards?

  • How does the clamp-on design reduce downtime compared to traditional flow meters?

  • What makes the Holykell ultrasonic flow meter suitable for high-temperature fluids?

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.