  • Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer
  • Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer
  • Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer
  • Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer
  • Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer
  • Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer
Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer

Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer

  • 1 - 4 Sets
    $6,500
  • >= 5 Sets
    $6,000

Customization:

Customized logo(Min.Order: 1 pieces)
Customized packaging(Min.Order: 1 pieces)

Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Element Quantification: Enables precise quantitative analysis of trace elements in samples via atomic absorption spectrophotometry (AAS), supporting detection at ultra-low concentrations.
  • Spectral Precision: Offers adjustable spectral bandwidths (0.2–5.0 nm) and a broad wavelength range (190–900 nm) for versatile elemental detection, with wavelength repeatability as low as ≤0.2 nm for high accuracy.

Key features

  • 1. Corrosion-Resistant Stainless Steel Construction

  • With a corrosion-resistant stainless steel body, you can ensure long-term durability in harsh laboratory environments compared to plastic-bodied models*. This robust material withstands chemical exposure and maintains structural integrity for reliable performance over time.

  • 2. Intuitive Keypad and Digital Display Interface

  • With an intuitive keypad and high-contrast digital display, you can streamline workflow efficiency compared to traditional non-digital interfaces*. Directly input parameters and monitor real-time analysis results for seamless operation.

  • 3. Precision Variable Spectral Bandwidth Technology

  • With variable spectral bandwidth settings (0.2–5.0 nm), you can achieve up to 20% higher precision than standard models* by optimizing sensitivity for diverse elemental analyses, such as trace metal detection.

  • 4. Broad Wavelength Range for Versatile Applications

  • With a wide wavelength range of 190–900 nm, you can analyze a broader spectrum of elements compared to narrower-range instruments*, supporting environmental, clinical, and industrial applications with consistent accuracy.

  • 5. ISO/ASTM-Certified Safety and Compliance

  • Equipped with ISO and ASTM-certified components, you can ensure adherence to global laboratory safety and performance standards*, minimizing risks and meeting regulatory requirements for critical analyses.

Product details

Laboratory Atomic Absorption Spectroscopy AAS Price Atomic Absorption Spectrometer

The DRAWELL Atomic Absorption Spectrometer (AAS) is a precision optical instrument designed for quantitative elemental analysis in laboratory settings. With a spectral bandwidth range from 0.2nm to 5.0nm and a wavelength coverage of 190-900 nm, it delivers high accuracy and versatility for diverse applications, including environmental testing, clinical research, and industrial quality control.

Technical specifications

FeatureSpecificationBenefit
Spectral Bandwidth0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nmAdjustable resolution for optimal sensitivity/resolution trade-off
Wavelength Range190-900 nmCovers a broad spectrum for multi-element analysis
Wavelength Repeatability≤0.2nm (Advanced/Pro), ≤0.3nm (Base)Ensures consistent measurements across samples
Material ConstructionStainless steel housingCorrosion-resistant and durable design

Customization guide

Adjustable spectral bandwidth parameters (0.2nm to 5.0nm) allow users to tailor resolution and sensitivity to specific analytical needs. The modular sample introduction system can be customized for liquid, solid, or gas-phase analysis, while wavelength calibration options ensure precision for specialized applications.

Get inspired

With its wide wavelength range and precise repeatability, the DRAWELL AAS is ideal for labs requiring reliable trace element detection. Whether analyzing heavy metals in water samples or trace contaminants in pharmaceuticals, this instrument delivers unmatched accuracy and flexibility.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Spectral Bandwidth1.4nm/2.4nm0.7nm/1.0nm0.2nm/0.4nm
Wavelength Repeatability≤0.3nm≤0.2nm≤0.1nm*
Detection Limitppm levelppb levelSub-ppb precision
CertificationsISO 8170ISO 8170 + ASTMISO 8170 + ASTM + CE

Supplier's note

  1. Technical Breakthroughs:

    • The Pro Model’s 0.2nm spectral bandwidth (30% narrower than industry standards) enables sub-ppb detection limits, ideal for ultra-trace analysis.
    • Wavelength repeatability ≤0.1nm (50% better than competitors) ensures unmatched consistency in high-throughput labs.
    • The 900 nm wavelength range covers over 70 elements, expanding applicability to rare earth metals and transition metals.
  2. Optimal Version Selection:

    • Base Model: Suitable for routine labs analyzing common elements (e.g., Na, K) with ppm-level requirements.
    • Advanced Model: Best for research institutions needing ppb-level precision (e.g., Pb, Cd in environmental samples).
    • Pro Model: Designed for cutting-edge research or regulatory labs requiring sub-ppb accuracy (e.g., As, Hg in pharmaceuticals).

Example Use Case:
With the Pro Model’s 0.2nm bandwidth, you can detect arsenic in drinking water at 0.5 ppb—3x more sensitive than traditional AAS systems. Paired with its sub-0.1nm repeatability, this ensures compliance with stringent EPA standards.

Note: Customizable parameters like bandwidth and accessories are available for specialized workflows.

Frequently asked questions

  • Which atomic absorption spectrophotometer model suits small laboratories with limited space?

  • How do I maintain the sample introduction system of an atomic absorption spectrophotometer?

  • Why is stainless steel construction preferred in atomic absorption spectrometers?

  • Can the DRAWELL AAS be customized for specific elemental analysis needs?

  • Is the DRAWELL atomic absorption spectrometer FDA/ISO-certified for clinical labs?

  • How does the spectral bandwidth selection affect analysis accuracy?

  • What advantages does the 190–900 nm wavelength range offer?

  • What safety features does the DRAWELL AAS include?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
High Sensitivity Elemental AnalysisTrace metal detection in water/soilSpectral Bandwidth: 0.2 nm (ISO 8996)▲▲▲ vs 1.4 nm (Base)Advanced: 0.2 nm ▲▲▲ enables detection of ppb-level contaminantsBase: 1.4 nm may miss low-concentration elements (e.g., <1 ppm)
Broad Wavelength Range CoverageMulti-element analysis (Na, Fe, Pb, etc.)Wavelength Range: 190-900 nm (ASTM E1621)▲▲▲Covers 80% of common elements in environmental/clinical labsLimited to visible/near-UV; requires accessories for IR wavelengths
Precision & RepeatabilityQuality control in pharmaceuticalsWavelength Repeatability: ≤0.2 nm (Advanced)▲ vs ≤0.3 nm (Base)Advanced: 0.2 nm ▲ ensures consistent results across batchesBase: 0.3 nm may require frequent recalibration for strict protocols
Cost-Effective Routine TestingAcademic labs with budget constraintsSpectral Bandwidth: 1.4 nm (Base)Base: 1.4 nm ▲ suffices for ppm-level analysis at 30% lower cost than AdvancedInadequate for regulatory compliance in industries like semiconductor manufacturing
Customizable Spectral BandwidthResearch labs needing flexibilitySelectable Bandwidth: 0.2–5.0 nm (Advanced)▲▲▲Advanced: Switch between 0.2 nm (high res) and 5.0 nm (fast scans)Base lacks variable bandwidth; fixed at 1.4 nm
PortabilityField-deployable testingWeight: 45 kg (Base/Advanced)Compact benchtop design fits standard lab benchesNon-portable; requires dedicated power/ventilation (disadvantage vs handheld AAS)

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.