All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier

Laboratory High Performance UV Detector Liquid Chromatography HPLC Analysis Instrument Price

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • High-Performance Separation & Quantification: Equipped with a UV detector (D1100) and precision pump (P1100), the system enables accurate separation, identification, and quantification of components in complex mixtures.
  • Automated Data Analysis: Integrated software provides real-time chromatogram visualization, statistical analysis, and method validation, streamlining workflow efficiency.

Key features

  • 1. Corrosion-Resistant Metal Construction

  • With a corrosion-resistant metal body, ensure long-term durability in chemically demanding laboratory environments. ~30% more resistant to acid/alkali exposure compared to plastic-bodied models*

  • 2. Touchscreen-Driven Automation

  • With an intuitive touchscreen interface and automated operation, streamline workflows with pre-programmed methods for rapid setup. Reduces manual intervention by up to 40% versus manual systems*

  • 3. Precision Flow & Sensitivity

  • With ±0.5% flow accuracy and UV detection sensitivity down to 0.001 AU, achieve high-resolution quantification. Outperforms standard detectors in sensitivity by 25%*

  • 4. Versatile Scenario Adaptability

  • With customizable method development and 24/7 continuous operation capabilities, address both research-grade precision and industrial-scale analysis. Ideal for pharmaceutical, environmental, and food safety applications.

  • 5. CE-Certified Reliability

  • With CE certification, meet EU safety and performance standards, ensuring compliance for laboratory use in regulated industries.

Product details

Laboratory High Performance UV Detector Liquid Chromatography HPLC Analysis Instrument Price

The Laboratory High Performance UV Detector Liquid Chromatography (HPLC) Analysis Instrument is a precision tool for separating, identifying, and quantifying components in complex mixtures. Certified to CE standards, it combines high-precision detection, customizable workflows, and advanced automation to meet the demands of pharmaceutical, environmental, and food science applications.

Technical specifications

FeatureSpecificationApplication Scenario
Detector TypeUV-Vis Detector (D1100)Pharmaceutical purity analysis
Wavelength Range190–800 nm (Pro Model: 190–900 nm)Broad-spectrum compound identification
Flow Rate Accuracy±0.5% (Base), ±0.2% (Pro)Critical sample quantification
Sensitivity0.001 AUFS (Advanced), 0.0005 AUFS (Pro)Trace component detection in R&D
Column MaterialStainless steel/glass compatibilityCustomized separation efficiency
Automation LevelSemi-automated (Advanced), Fully automated (Pro)High-throughput lab workflows
CertificationCE-compliantEU regulatory compliance for lab use

Customization guide

Adjustable parameters include flow rate (0.01–10 mL/min), detector wavelength settings, and column selection (e.g., C18, silica-based). Users can tailor these to match specific analyte properties, such as polarity or volatility, for optimal separation.

Get inspired

Whether optimizing drug formulations or analyzing environmental contaminants, this HPLC system empowers researchers to achieve reproducible results with minimal downtime. Its modular design allows seamless integration into existing lab workflows.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Wavelength Range190–700 nm190–800 nm190–900 nm (+10%)
Flow Rate Accuracy±0.5%±0.3%±0.2%
Detection Limit0.01 AUFS0.001 AUFS0.0005 AUFS
AutomationManual setupSemi-automatedFull automation
Price TierEntry-levelMid-rangePremium

Supplier's note

  1. Technical Breakthroughs:

    • The Pro Model’s 190–900 nm wavelength range enables analysis of near-UV compounds, expanding applicability in polymer and pesticide studies.
    • Full automation reduces hands-on time by 40%, ideal for 24/7 lab operations.
    • Enhanced 0.0005 AUFS sensitivity (Pro) ensures detection of trace contaminants in ultra-pure water samples.
  2. Version Selection Guide:

    • Base Model: Suitable for routine QA/QC labs requiring basic separation (e.g., simple pharmaceutical assays).
    • Advanced Model: Best for mid-sized labs needing precision (e.g., food safety testing with volatile analytes).
    • Pro Model: Required for cutting-edge R&D (e.g., biopharma peptide analysis or environmental toxin detection). With its triple-certified chemical resistance, the Pro ensures safe handling of corrosive solvents. Pair its stainless steel column compatibility with automated methods to achieve 99.9% reproducibility.

With the Pro’s extended wavelength range, you can analyze a broader spectrum of compounds than traditional systems. The Advanced Model’s 20% faster flow rate accuracy reduces analysis time for time-sensitive workflows. Choose wisely to align with your lab’s analytical complexity and throughput needs.

Frequently asked questions

  • Which HPLC model is best suited for pharmaceutical quality control labs?

  • How do I clean the pump unit of an HPLC system to prevent clogging?

  • Is the HPLC system CE-certified for pharmaceutical use?

  • Can the HPLC software be customized for specific analytical methods?

  • What makes the UV detector in this HPLC system suitable for trace analysis?

  • Does the HPLC system support unattended operation for high-throughput labs?

  • How does the column compartment design ensure consistent separation efficiency?

  • What data analysis tools are included with the HPLC software for method validation?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Detector SensitivityTrace analysis in pharmaceuticalsIndustry Standard: 0.001 AU (ISO 17025)
Our Base: 0.0005 AU (▲1)
Our Advanced: 0.0002 AU (▲2)
▲1: Detects contaminants at 10ppb levels; ▲2: Identifies rare compounds in complex matricesAdvanced version requires specialized calibration (cost +20%)
Flow Rate PrecisionDrug development (high-precision assays)Industry: ±2% (ASTM D6353)
Our Base: ±1% (▲1)
Our Advanced: ±0.5% (▲2)
▲1: Reduces batch variability by 30%; ▲2: Ensures 99.5% repeatability in critical assaysBase model lacks auto-correction for pressure fluctuations
Noise LevelHospital labs (shared spaces)Industry: 50 dBA (OSHA compliance)
Our Base: 45 dBA (▲1)
Our Advanced: 40 dBA (▲2)
▲1: Meets ISO 1999 acoustic comfort standards; ▲2: Quieter than a whisper (ideal for clinical labs)Advanced cooling system increases power consumption by 15%
Data Analysis SoftwareRegulatory compliance reportingIndustry: Basic peak integration (FDA 21 CFR Part 11)
Our Base: AI-driven baseline correction (▲1)
Our Advanced: Predictive analytics + FDA/EMA templates (▲2)
▲1: Cuts report prep time by 50%; ▲2: Automates GLP/GMP compliance checksAdvanced requires 16+ hours of training for full utilization
Column CompatibilityEnvironmental toxin analysisIndustry: Standard C18 columns only
Our Base: 12+ column types (▲1)
Our Advanced: Customizable HILIC/Chiral columns (▲2)
▲1: Supports polar compounds; ▲2: Separates enantiomers in chiral drugsAdvanced columns cost 3x more than industry-standard options
CertificationGlobal market deploymentIndustry: ISO 9001
Our Base: CE + ISO 17025 (▲1)
Our Advanced: CE + FDA 21 CFR Part 11 + IVD-IVDR (▲2)
▲1: Access to EU/Asia markets; ▲2: Pre-qualified for US/EU clinical labsAdvanced certification adds 6 months to delivery timelines

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.