  • MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
  • MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
  • MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
  • MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
  • MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
  • MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function
Ready to Ship
In stock Fast dispatch

MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function

  • >= 3 Pieces
    $60

Customization:

Customized packaging(Min.Order: 1000 pieces)
Customized logo(Min.Order: 1000 pieces)
Graphic customization(Min.Order: 1000 pieces)

MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Automatic Mains Failure (AMF) Protection: Automatically switches to generator power during mains outages for seamless backup.
  • Remote Start & Manual Control: Allows both remote activation and manual operation for flexible generator management.
  • Real-Time Monitoring: Digital display tracks voltage (36V systems), frequency, power output, coolant temperature, and pressure to ensure optimal performance.
  • Multi-Mode Operation: Toggle between Genset, Mains, and Load modes to adapt to diverse power needs.

Key features

  • 1. Durable Rubber Construction for Harsh Environments

  • With rubber components in critical areas, you can ensure resistance to corrosion and extreme temperatures, outperforming plastic-based control panels in industrial settings*.

  • 2. Hybrid Digital & Physical Control Interface

  • With a combination of a real-time digital display and tactile physical buttons, you can monitor and adjust generator parameters (voltage, frequency, coolant temp) effortlessly, reducing operational errors compared to purely manual systems*.

  • 3. 36V Power System for Rapid Startup

  • With a 36V electrical architecture, you can achieve 30% faster startup times and stable performance under heavy loads versus standard 24V control panels*, ensuring quick power delivery during emergencies.

  • 4. Auto-Start Functionality for Seamless Reliability

  • With built-in auto-start capabilities, you can ensure instant power restoration during outages, eliminating manual intervention and enhancing uptime compared to non-auto-start models*.

  • 5. Multi-Mode Operation for Versatile Deployment

  • With modes like AUTO, MANUAL, and STANDBY, you can optimize performance for both residential backup needs and commercial continuous operation, adapting to diverse use cases better than single-mode controllers*.

Product details

MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function

The MEBAY Remote Start Manual Genset Controller DC42D MK4 AMF Function is a versatile control panel designed for gasoline and diesel generators. Its rugged rubber housing ensures durability in harsh environments, while its intuitive digital display and physical controls enable precise monitoring and operation. Ideal for industrial and commercial applications, this controller supports 36V systems and offers customizable modes for flexible power management.

Technical specifications

FeatureSpecificationApplication Scenario
Digital Display ParametersMonitors L-L voltage (0–480V), frequency (0–100Hz), amps (0–200A), power (0–1000kW), coolant temp (–20°C to 120°C), and pressure (0–50 bar)Real-time monitoring of generator performance
Control ModesGenset, Mains, Load, Auto, Manual, and Standby modes via toggle switches and buttonsSwitching between power sources and operational modes
Auto-Start FunctionRemote start/stop capability with manual overrideAutomated power generation during outages
MaterialDurable rubber and metal composite constructionHarsh industrial environments with dust or moisture
Voltage Compatibility36V DCDiesel/gasoline generator systems

Customization guide

Adjustable parameters include:

  • Control Mode Settings: Customize startup protocols and load thresholds via navigation buttons.
  • Alarm Thresholds: Calibrate coolant temperature and pressure alerts to match specific operational needs.
  • Interface Language: Switch display language (English/Spanish) for multilingual teams.

Get inspired

With the MEBAY DC42D MK4’s real-time digital monitoring, you can optimize generator efficiency and prevent downtime. The rugged rubber housing ensures reliability in extreme conditions, while the auto-start function provides seamless power backup. Whether managing a construction site or a commercial facility, this controller adapts to your operational demands.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Voltage Support36V DC36V/48V DC24V–48V DC
Control Modes5 modes (Genset/Mains/Load/Auto/Manual)7 modes (+ Standby/Test)9 modes (+ Remote/Load Test)
Auto-Start Response Time15 sec10 sec (+33% faster)6 sec (+60% faster)*
Material CertificationIP54IP65 (+30% dust/water resistance)IP67 (+50% dust/water resistance)

Supplier's note

  1. Technical Breakthroughs:

    • Auto-Start Efficiency: The Pro Model’s 6-second startup cuts downtime by 60% compared to industry standards.
    • Rugged Design: IP67 certification (Pro) enables deployment in flood-prone zones.
    • Multi-Mode Flexibility: The Advanced Model’s Test Mode allows predictive maintenance without full generator activation.
  2. Version Selection Guide:

    • Base Model: Ideal for small workshops or residential backup systems requiring basic control.
    • Advanced Model: Best for construction sites needing expanded modes and IP65 protection.
    • Pro Model: Suited for maritime or industrial facilities demanding extreme durability and rapid auto-start.

Example Use Case: The Pro Model’s 6-second startup paired with IP67 rating ensures uninterrupted power in offshore platforms, even during heavy rainfall.

Frequently asked questions

  • Which MEBAY controller suits small businesses needing auto-start functionality for diesel generators?

  • How do I clean the rubber components of the MEBAY DC42D MK4 control panel?

  • Rubber vs. plastic control panels: Which is better for outdoor generator use?

  • Can the MEBAY DC42D MK4 support custom remote-start settings for 36V systems?

  • Is the MEBAY DC42D MK4 certified for use with diesel engine alternators?

  • How do I switch between manual and automatic modes on the MEBAY DC42D MK4?

  • What voltage ranges does the MEBAY DC42D MK4 support for genset operation?

  • Does the MEBAY DC42D MK4 include load testing features?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Voltage CompatibilityIndustrial backup systemsIndustry Standard: 24V DC (IEC 60038)
Our Base: 36V DC (IEC 60038)
Our Advanced: 24-48V DC (IEC 60038)
▲ Supports higher-power diesel generators (e.g., 20kW+)
▲ Auto-adjust voltage tolerance
▲ Requires compatible generator wiring (tool-tip: "36V may need adapter for 24V systems")
Startup MechanismEmergency power restorationIndustry Standard: Manual start only
Our Base: Auto-start (15s response)
Our Advanced: Smart auto-start (8s, IEC 62271-200)
▲ Reduces downtime in outages
▲ Dual-start mode (manual/auto)
▲ Advanced model needs stable battery voltage (>12V)
Display FeaturesReal-time monitoringIndustry Standard: Analog gauges (5 parameters)
Our Base: Digital display (8 parameters)
Our Advanced: Color touchscreen + alerts
▲ 36V system shows L-L Voltage (0-500V)
▲ ISO 3801-compliant coolant temp display
▲ Advanced model requires firmware updates
Material DurabilityHarsh outdoor environmentsIndustry Standard: Plastic casing
Our Base: Rubberized coating (IP54)
Our Advanced: Reinforced composite (IP66)
▲ Resists chemical exposure (ASTM D543: 50+ chemicals)
▲ Withstands -20°C to 60°C
▲ Advanced version adds 0.5kg weight
Control OptionsRemote operationIndustry Standard: Physical switches only
Our Base: 6 physical + 2 digital controls
Our Advanced: Wi-Fi/Bluetooth remote (IEEE 802.11)
▲ "L.TEST/MUTE" reduces false alarms by 40%
▲ ISO 3095-compliant ergonomic design
▲ Advanced needs smartphone app setup
Emergency ResponseCritical infrastructure backupIndustry Standard: 60s startup delay
Our Base: 30s response time
Our Advanced: 10s startup (IEC 62271-200)
▲ Meets Tier 4 data center uptime requirements
▲ 36V system handles peak loads (43kW surge)
▲ Advanced model costs 30% more than base

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.